Product Model
231-336/108-000

Selling Points
- 1Reliable PCB Connection: Secure and efficient connections for various industrial and automation systems.
- 26-Pole THT Design: Suitable for horizontal or vertical PCB mounting with straight solder pins.
- 3Robust Construction: 1.0 x 1.0 mm solder pins ensure high-performance connections.
- 4Threaded Flanges: Easy installation and secure mounting options.
- 5Orange Color Coding: Easy identification on PCBs with orange color coding.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Safety information | TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated. | Variants: | Other pole numbers |
Total number of potentials | 6 | Number of connection types | 1 |
Number of levels | 1 | Pin spacing | 5.08?mm?/ 0.2?inches |
Width | 40.48?mm?/ 1.594?inches | Height | 17?mm?/ 0.669?inches |
Height from the surface | 12?mm?/ 0.472?inches | Depth | 8.4?mm?/ 0.331?inches |
Solder pin length | 5mm | Solder pin dimensions | 1 x 1?mm |
Drilled hole diameter with tolerance | 1.4(+0.1)mm | Variable coding | Yes |
Anti-rotation protection | Yes | Contact type (pluggable connector) | Male connector/plug |
Connector (connection type) | for PCB | Mismating protection | No |
Plugging without loss of pin spacing | No | Mating direction to the PCB | 90° |
Locking of plug-in connection | Threaded flange | PCB contact | THT |
Solder pin arrangement | over the entire male connector (in-line) | Number of solder pins per potential | 1 |
Note (material data) | Information on material specifications can be found here | Color | orange |
Material group | I | Insulation material (main housing) | Polyamide (PA66) |
Flammability class per UL94 | V0 | Contact material | Electrolytic copper (ECu) |
Contact plating | Tin | Fire load | 0.048MJ |
Weight | 2.7g | Limit temperature range | -60 … +100?°C |
Processing temperature | -35 … +60?°C | Product Group | 3 (Multi Conn. System) |
eCl@ss 10.0 | 27-44-04-02 | eCl@ss 9.0 | 27-44-04-02 |
ETIM 9.0 | EC002637 | ETIM 8.0 | EC002637 |
ECCN | NO US CLASSIFICATION | PU (SPU) | 100?pcs |
Packaging type | box | Country of origin | PL |
GTIN | 4044918865401 | Customs tariff number | 8536694040 |
CAS-No. | 7439-92-1 | REACH Candidate List Substance | Lead |
RoHS Compliance Status | Compliant,With Exemption | RoHS Exemption | 6(c) |
SCIP notification number (Austria) | 09f139ad-1b24-412f-8b53-2591ae241091 | SCIP notification number (Belgium) | 93dd334d-7e15-4dec-a60f-54107c16da72 |
SCIP notification number (Bulgaria) | e1456e0e-fd34-48bc-83ad-11d481e35957 | SCIP notification number (Czech Republic) | c99f63bd-debf-4788-a458-f84c00570895 |
SCIP notification number (Denmark) | 624528fa-d9bc-43b9-8e57-7efbf8ee6af3 | SCIP notification number (Finland) | 99f1d04c-59eb-483a-8863-4efc8b2190f7 |
SCIP notification number (France) | 89140627-a347-4b6e-ada9-b70fa821c6fe | SCIP notification number (Germany) | 6ddb6837-4643-428f-a0e6-2fae60aa4de6 |
SCIP notification number (Hungary) | edff979b-830d-4d75-afbf-f9e11c4c3e65 | SCIP notification number (Italy) | 1488a7bc-b073-48ad-b988-9610d55b3e1c |
SCIP notification number (Netherlands) | d5724e66-abf7-4e58-afca-34d080351eb4 | SCIP notification number (Poland) | 7cea3455-b4f9-4014-9e54-31be7d107f2e |
SCIP notification number (Romania) | a497bf9c-ef27-495c-9d47-5dc5f7fcec9f | SCIP notification number (Sweden) | f5042981-8462-4b7b-9e15-4904d55eaaeb |
Ratings per | IEC/EN 60664-1 | Rated voltage (III / 3) | 320V |
Rated impulse voltage (III / 3) | 4kV | Rated voltage (III/2) | 320V |
Rated surge voltage (III/2) | 4kV | Nominal voltage (II/2) | 630V |
Rated surge voltage (II/2) | 4kV | Rated current | 12A |
Legend (ratings) | (III / 2) ? Overvoltage category III / Pollution degree 2 | Approvals per | CSA |
Rated voltage UL (Use Group B) | 300V | Rated current UL (Use Group B) | 10A |
Rated voltage UL (Use Group D) | 300V | Rated current UL (Use Group D) | 10A |
Rated voltage (UL 1977) | 600V | Rated current UL 1977 | 10A |
Rated voltage CSA (Use Group B) | 300V | Rated current CSA (Use Group B) | 10A |
Rated voltage CSA (Use Group D) | 300V | Rated current CSA (Use Group D) | 10A |
Number of poles | 6 | Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment | DIN EN 50155 (VDE 0115-200):2022-06 |
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests | DIN EN 61373 (VDE 0115-0106):2011-04 | Spectrum/Installation location | Service life test, Category?1, Class?A/B |
Function test with noise-like vibration | Test passed according to Section 8 of the standard | Frequency | f1= 5 Hz to f2= 150 Hz |
Acceleration | 5g (highest test level used for all axes) | Test duration per axis | 5 h |
Test directions | X, Y and Z axes | Monitoring for contact faults/interruptions | Passed |
Voltage drop measurement before and after each axis | Passed | Simulated service life test through increased levels of noise-like vibration | Test passed according to Section 9 of the standard |
Extended test scope: Monitoring for contact faults/interruptions | Passed | Extended test scope: Voltage drop measurement before and after each axis | Passed |
Shock test | Test passed according to Section 10 of the standard | Shock form | Half sine |
Shock duration | 30 ms | Number of shocks per axis | 3 pos. und 3 neg. |
Vibration and shock stress for rolling stock equipment | Passed |
Specifications may be subject to change without notice