Product Model
231-342/108-000

Selling Points
- 1High-Reliability Design: Built with durable materials for long-lasting connections.
- 2Versatile Connectivity: Supports both 12-pin and 1-reel configurations.
- 3Easy Installation: Simple solder connection for quick setup.
- 4Precise Pitch: 5.08mm pitch ensures accurate and secure connections.
- 5Durable Construction: Suitable for a wide range of electronic applications.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Safety information | TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated. | Variants: | Other pole numbers |
Total number of potentials | 12 | Number of connection types | 1 |
Number of levels | 1 | Pin spacing | 5.08?mm?/ 0.2?inches |
Width | 70.96?mm?/ 2.794?inches | Height | 17?mm?/ 0.669?inches |
Height from the surface | 12?mm?/ 0.472?inches | Depth | 8.4?mm?/ 0.331?inches |
Solder pin length | 5mm | Solder pin dimensions | 1 x 1?mm |
Drilled hole diameter with tolerance | 1.4(+0.1)mm | Variable coding | Yes |
Anti-rotation protection | Yes | Contact type (pluggable connector) | Male connector/plug |
Connector (connection type) | for PCB | Mismating protection | No |
Plugging without loss of pin spacing | No | Mating direction to the PCB | 90° |
Locking of plug-in connection | Threaded flange | PCB contact | THT |
Solder pin arrangement | over the entire male connector (in-line) | Number of solder pins per potential | 1 |
Note (material data) | Information on material specifications can be found here | Color | orange |
Material group | I | Insulation material (main housing) | Polyamide (PA66) |
Flammability class per UL94 | V0 | Contact material | Electrolytic copper (ECu) |
Contact plating | Tin | Fire load | 0.079MJ |
Weight | 4.5g | Limit temperature range | -60 … +100?°C |
Processing temperature | -35 … +60?°C | Product Group | 3 (Multi Conn. System) |
eCl@ss 10.0 | 27-44-04-02 | eCl@ss 9.0 | 27-44-04-02 |
ETIM 9.0 | EC002637 | ETIM 8.0 | EC002637 |
ECCN | NO US CLASSIFICATION | PU (SPU) | 100?pcs |
Packaging type | box | Country of origin | DE |
GTIN | 4045454029159 | Customs tariff number | 8536694040 |
CAS-No. | 7439-92-1 | REACH Candidate List Substance | Lead |
RoHS Compliance Status | Compliant,With Exemption | RoHS Exemption | 6(c) |
SCIP notification number (Austria) | 750fb22b-202a-4cc7-8111-64dbb0c4c980 | SCIP notification number (Belgium) | fe05830b-10a7-488d-ab84-89f2c11ed963 |
SCIP notification number (Bulgaria) | ea2f5969-ad1e-41d7-b16f-b66e711a9aa0 | SCIP notification number (Czech Republic) | 72e30cd2-c8d5-42c9-88d7-c16c9b1d94ef |
SCIP notification number (Denmark) | 2697ccc2-74c2-43ee-87e5-38f2fdbe05f0 | SCIP notification number (Finland) | 798981ce-ac8d-4c33-9ff1-a22e4784a6a0 |
SCIP notification number (France) | 891932be-526c-441c-bf32-3388849e86a6 | SCIP notification number (Germany) | bf2df7d3-e00a-4355-941a-36821b140093 |
SCIP notification number (Hungary) | 27772992-7af7-49a5-bfe8-34009c0f9947 | SCIP notification number (Italy) | 5e993602-341c-418b-b982-af8a2307ea9e |
SCIP notification number (Netherlands) | 2620ee74-8396-4b0b-800d-21b4324099a2 | SCIP notification number (Poland) | 4b33325e-cfd4-4313-98e6-e1413422bad1 |
SCIP notification number (Romania) | e659ef1f-5d84-480d-aa88-72c30341aeaf | SCIP notification number (Sweden) | 1c03277f-ea79-494a-8f79-9f08be8bd84b |
Ratings per | IEC/EN 60664-1 | Rated voltage (III / 3) | 320V |
Rated impulse voltage (III / 3) | 4kV | Rated voltage (III/2) | 320V |
Rated surge voltage (III/2) | 4kV | Nominal voltage (II/2) | 630V |
Rated surge voltage (II/2) | 4kV | Rated current | 12A |
Legend (ratings) | (III / 2) ? Overvoltage category III / Pollution degree 2 | Approvals per | CSA |
Rated voltage UL (Use Group B) | 300V | Rated current UL (Use Group B) | 10A |
Rated voltage UL (Use Group D) | 300V | Rated current UL (Use Group D) | 10A |
Rated voltage (UL 1977) | 600V | Rated current UL 1977 | 10A |
Rated voltage CSA (Use Group B) | 300V | Rated current CSA (Use Group B) | 10A |
Rated voltage CSA (Use Group D) | 300V | Rated current CSA (Use Group D) | 10A |
Number of poles | 12 | Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment | DIN EN 50155 (VDE 0115-200):2022-06 |
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests | DIN EN 61373 (VDE 0115-0106):2011-04 | Spectrum/Installation location | Service life test, Category?1, Class?A/B |
Function test with noise-like vibration | Test passed according to Section 8 of the standard | Frequency | f1= 5 Hz to f2= 150 Hz |
Acceleration | 5g (highest test level used for all axes) | Test duration per axis | 5 h |
Test directions | X, Y and Z axes | Monitoring for contact faults/interruptions | Passed |
Voltage drop measurement before and after each axis | Passed | Simulated service life test through increased levels of noise-like vibration | Test passed according to Section 9 of the standard |
Extended test scope: Monitoring for contact faults/interruptions | Passed | Extended test scope: Voltage drop measurement before and after each axis | Passed |
Shock test | Test passed according to Section 10 of the standard | Shock form | Half sine |
Shock duration | 30 ms | Number of shocks per axis | 3 pos. und 3 neg. |
Vibration and shock stress for rolling stock equipment | Passed |
Specifications may be subject to change without notice