Product Model
231-345/108-000

Selling Points
- 1High-reliability connectivity for critical industrial applications.
- 2Efficient signal transmission with minimal signal loss.
- 3Compact design for easy integration into existing systems.
- 4Robust construction to withstand harsh environmental conditions.
- 5Easy installation and maintenance with intuitive design features.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Safety information | TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated. | Variants: | Other pole numbers |
Total number of potentials | 15 | Number of connection types | 1 |
Number of levels | 1 | Pin spacing | 5.08?mm?/ 0.2?inches |
Width | 86.2?mm?/ 3.394?inches | Height | 17?mm?/ 0.669?inches |
Height from the surface | 12?mm?/ 0.472?inches | Depth | 8.4?mm?/ 0.331?inches |
Solder pin length | 5mm | Solder pin dimensions | 1 x 1?mm |
Drilled hole diameter with tolerance | 1.4(+0.1)mm | Variable coding | Yes |
Anti-rotation protection | Yes | Contact type (pluggable connector) | Male connector/plug |
Connector (connection type) | for PCB | Mismating protection | No |
Plugging without loss of pin spacing | No | Mating direction to the PCB | 90° |
Locking of plug-in connection | Threaded flange | PCB contact | THT |
Solder pin arrangement | over the entire male connector (in-line) | Number of solder pins per potential | 1 |
Note (material data) | Information on material specifications can be found here | Color | orange |
Material group | I | Insulation material (main housing) | Polyamide (PA66) |
Flammability class per UL94 | V0 | Contact material | Electrolytic copper (ECu) |
Contact plating | Tin | Fire load | 0.1MJ |
Weight | 5.6g | Limit temperature range | -60 … +100?°C |
Processing temperature | -35 … +60?°C | Product Group | 3 (Multi Conn. System) |
eCl@ss 10.0 | 27-44-04-02 | eCl@ss 9.0 | 27-44-04-02 |
ETIM 9.0 | EC002637 | ETIM 8.0 | EC002637 |
ECCN | NO US CLASSIFICATION | PU (SPU) | 50?pcs |
Packaging type | box | Country of origin | PL |
GTIN | 4044918865753 | Customs tariff number | 8536694040 |
CAS-No. | 7439-92-1 | REACH Candidate List Substance | Lead |
RoHS Compliance Status | Compliant,With Exemption | RoHS Exemption | 6(c) |
SCIP notification number (Austria) | 8267d8fc-c687-42c7-a09b-efe0820a7bef | SCIP notification number (Belgium) | 536c1089-b534-43db-aab9-d9b0beed93d8 |
SCIP notification number (Bulgaria) | adb5c9f2-83fa-410f-a17d-028775b62b06 | SCIP notification number (Czech Republic) | e089a185-bd27-47d5-8397-3be1bcf1f1cd |
SCIP notification number (Denmark) | d318097c-da81-4f81-969f-e44527abfda6 | SCIP notification number (Finland) | 4f9647ae-5730-42f3-81f1-1f949824483c |
SCIP notification number (France) | 2fea878d-d423-42dc-a469-60cd66d9ef8c | SCIP notification number (Germany) | d78d60b2-013a-4238-8bf2-445eab8998f4 |
SCIP notification number (Hungary) | 60cd9742-2783-408f-bac1-0655cd415547 | SCIP notification number (Italy) | faf56ca5-749c-43da-bdd7-ab78a2f77342 |
SCIP notification number (Netherlands) | 34056eab-504a-4b60-9ebe-99319984d140 | SCIP notification number (Poland) | 7d3cff9b-d1ff-4262-a084-8965a1ffbc09 |
SCIP notification number (Romania) | 5c5a6c68-ab71-4ed3-b20c-5cf010ae048a | SCIP notification number (Sweden) | 39fbb248-c64a-4a96-bab2-235ded9d432b |
Ratings per | IEC/EN 60664-1 | Rated voltage (III / 3) | 320V |
Rated impulse voltage (III / 3) | 4kV | Rated voltage (III/2) | 320V |
Rated surge voltage (III/2) | 4kV | Nominal voltage (II/2) | 630V |
Rated surge voltage (II/2) | 4kV | Rated current | 12A |
Legend (ratings) | (III / 2) ? Overvoltage category III / Pollution degree 2 | Approvals per | CSA |
Rated voltage UL (Use Group B) | 300V | Rated current UL (Use Group B) | 10A |
Rated voltage UL (Use Group D) | 300V | Rated current UL (Use Group D) | 10A |
Rated voltage (UL 1977) | 600V | Rated current UL 1977 | 10A |
Rated voltage CSA (Use Group B) | 300V | Rated current CSA (Use Group B) | 10A |
Rated voltage CSA (Use Group D) | 300V | Rated current CSA (Use Group D) | 10A |
Number of poles | 15 | Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment | DIN EN 50155 (VDE 0115-200):2022-06 |
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests | DIN EN 61373 (VDE 0115-0106):2011-04 | Spectrum/Installation location | Service life test, Category?1, Class?A/B |
Function test with noise-like vibration | Test passed according to Section 8 of the standard | Frequency | f1= 5 Hz to f2= 150 Hz |
Acceleration | 5g (highest test level used for all axes) | Test duration per axis | 5 h |
Test directions | X, Y and Z axes | Monitoring for contact faults/interruptions | Passed |
Voltage drop measurement before and after each axis | Passed | Simulated service life test through increased levels of noise-like vibration | Test passed according to Section 9 of the standard |
Extended test scope: Monitoring for contact faults/interruptions | Passed | Extended test scope: Voltage drop measurement before and after each axis | Passed |
Shock test | Test passed according to Section 10 of the standard | Shock form | Half sine |
Shock duration | 30 ms | Number of shocks per axis | 3 pos. und 3 neg. |
Vibration and shock stress for rolling stock equipment | Passed |
Specifications may be subject to change without notice