Product Model
231-346/108-000

Selling Points
- 1Highly Reliable PCB Connector: Designed for secure and durable connections.
- 216-Pole Configuration: Suitable for various electronic applications.
- 31.0 x 1.0 mm Solder Pins: Easy to solder and maintain.
- 4Threaded Flanges: Allows for easy mounting on PCBs.
- 5Orange Color Coding: Enhances visibility and organization in your workspace.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Safety information | TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated. | Variants: | Other pole numbers |
Total number of potentials | 16 | Number of connection types | 1 |
Number of levels | 1 | Pin spacing | 5.08?mm?/ 0.2?inches |
Width | 91.28?mm?/ 3.594?inches | Height | 17?mm?/ 0.669?inches |
Height from the surface | 12?mm?/ 0.472?inches | Depth | 8.4?mm?/ 0.331?inches |
Solder pin length | 5mm | Solder pin dimensions | 1 x 1?mm |
Drilled hole diameter with tolerance | 1.4(+0.1)mm | Variable coding | Yes |
Anti-rotation protection | Yes | Contact type (pluggable connector) | Male connector/plug |
Connector (connection type) | for PCB | Mismating protection | No |
Plugging without loss of pin spacing | No | Mating direction to the PCB | 90° |
Locking of plug-in connection | Threaded flange | PCB contact | THT |
Solder pin arrangement | over the entire male connector (in-line) | Number of solder pins per potential | 1 |
Note (material data) | Information on material specifications can be found here | Color | orange |
Material group | I | Insulation material (main housing) | Polyamide (PA66) |
Flammability class per UL94 | V0 | Contact material | Electrolytic copper (ECu) |
Contact plating | Tin | Fire load | 0.102MJ |
Weight | 5.8g | Limit temperature range | -60 … +100?°C |
Processing temperature | -35 … +60?°C | Product Group | 3 (Multi Conn. System) |
eCl@ss 10.0 | 27-44-04-02 | eCl@ss 9.0 | 27-44-04-02 |
ETIM 9.0 | EC002637 | ETIM 8.0 | EC002637 |
ECCN | NO US CLASSIFICATION | PU (SPU) | 50?pcs |
Packaging type | box | Country of origin | PL |
GTIN | 4045454029173 | Customs tariff number | 8536694040 |
CAS-No. | 7439-92-1 | REACH Candidate List Substance | Lead |
RoHS Compliance Status | Compliant,With Exemption | RoHS Exemption | 6(c) |
SCIP notification number (Austria) | 06380b25-04f5-4bcc-b9c3-912ee6f7dd14 | SCIP notification number (Belgium) | 3f91cb0b-aad6-464d-a7e0-d40a740752d5 |
SCIP notification number (Bulgaria) | 892487d1-e274-477d-af3e-f8eea3030749 | SCIP notification number (Czech Republic) | 8d6c7d53-8531-49d3-8735-7b4490d82384 |
SCIP notification number (Denmark) | 966feeed-db40-4a0c-a21c-0d16b66cac00 | SCIP notification number (Finland) | 81321a22-2fdf-462e-9127-bd6be2712688 |
SCIP notification number (France) | 47ecc41d-8efa-4634-ae52-6a5b4f81da88 | SCIP notification number (Germany) | fd665e75-ecb4-4de5-ba05-40b4b7a3bdd4 |
SCIP notification number (Hungary) | f359b52c-1c34-43a7-8636-dcb5ad6e8888 | SCIP notification number (Italy) | 23ab09f0-0420-4598-ade9-b08718f613c8 |
SCIP notification number (Netherlands) | 217d525a-ce5c-4e72-b79d-7f826ece4ca7 | SCIP notification number (Poland) | 7ae97f53-c902-4047-a548-97a5c557f18e |
SCIP notification number (Romania) | a0e487dd-611a-402b-a7c0-8e1039fa5bea | SCIP notification number (Sweden) | e4dfa69d-9f7c-4b45-9bda-71ba6f3040a8 |
Ratings per | IEC/EN 60664-1 | Rated voltage (III / 3) | 320V |
Rated impulse voltage (III / 3) | 4kV | Rated voltage (III/2) | 320V |
Rated surge voltage (III/2) | 4kV | Nominal voltage (II/2) | 630V |
Rated surge voltage (II/2) | 4kV | Rated current | 12A |
Legend (ratings) | (III / 2) ? Overvoltage category III / Pollution degree 2 | Approvals per | CSA |
Rated voltage UL (Use Group B) | 300V | Rated current UL (Use Group B) | 10A |
Rated voltage UL (Use Group D) | 300V | Rated current UL (Use Group D) | 10A |
Rated voltage (UL 1977) | 600V | Rated current UL 1977 | 10A |
Rated voltage CSA (Use Group B) | 300V | Rated current CSA (Use Group B) | 10A |
Rated voltage CSA (Use Group D) | 300V | Rated current CSA (Use Group D) | 10A |
Number of poles | 16 | Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment | DIN EN 50155 (VDE 0115-200):2022-06 |
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests | DIN EN 61373 (VDE 0115-0106):2011-04 | Spectrum/Installation location | Service life test, Category?1, Class?A/B |
Function test with noise-like vibration | Test passed according to Section 8 of the standard | Frequency | f1= 5 Hz to f2= 150 Hz |
Acceleration | 5g (highest test level used for all axes) | Test duration per axis | 5 h |
Test directions | X, Y and Z axes | Monitoring for contact faults/interruptions | Passed |
Voltage drop measurement before and after each axis | Passed | Simulated service life test through increased levels of noise-like vibration | Test passed according to Section 9 of the standard |
Extended test scope: Monitoring for contact faults/interruptions | Passed | Extended test scope: Voltage drop measurement before and after each axis | Passed |
Shock test | Test passed according to Section 10 of the standard | Shock form | Half sine |
Shock duration | 30 ms | Number of shocks per axis | 3 pos. und 3 neg. |
Vibration and shock stress for rolling stock equipment | Passed |
Specifications may be subject to change without notice