Product Model

231-365/108-000

In Stock
Last updated: 2025/4/25
wago 231-365/108-000

Selling Points

  • 1High Current Rating: Supports up to 16A current, ideal for stable and efficient connections.
  • 2Durable Design: Constructed with electro-copper contacts and polyamide insulation for long-lasting performance.
  • 3Easy Installation: Straight and threaded flange design ensures secure mounting on PCBs.
  • 4Safety Features: Includes anti-rotation protection and no mismating protection for safe operation.
  • 5Compliant with Standards: Meets IEC/EN, UL, and CSA standards for overvoltage and surge protection.
Product Details
231-365/108-000
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Safety information
TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated.
Variants:
Other pole numbers
Total number of potentials
5
Number of connection types
1
Number of levels
1
Pin spacing
5.08?mm?/ 0.2?inches
Width
35.4?mm?/ 1.394?inches
Height
17?mm?/ 0.669?inches
Height from the surface
12?mm?/ 0.472?inches
Depth
8.4?mm?/ 0.331?inches
Solder pin length
5mm
Solder pin dimensions
1.2 x 1.2?mm
Drilled hole diameter with tolerance
1.7(+0.1)mm
Variable coding
Yes
Anti-rotation protection
Yes
Contact type (pluggable connector)
Male connector/plug
Connector (connection type)
for PCB
Mismating protection
No
Plugging without loss of pin spacing
No
Mating direction to the PCB
90°
Locking of plug-in connection
Threaded flange
PCB contact
THT
Solder pin arrangement
over the entire male connector (in-line)
Number of solder pins per potential
1
Note (material data)
Information on material specifications can be found here
Color
orange
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Contact material
Electrolytic copper (ECu)
Contact plating
Tin
Fire load
0.042MJ
Weight
2.7g
Limit temperature range
-60 … +100?°C
Processing temperature
-35 … +60?°C
Product Group
3 (Multi Conn. System)
eCl@ss 10.0
27-44-04-02
eCl@ss 9.0
27-44-04-02
ETIM 9.0
EC002637
ETIM 8.0
EC002637
ECCN
NO US CLASSIFICATION
PU (SPU)
100?pcs
Packaging type
box
Country of origin
PL
GTIN
4045454845650
Customs tariff number
8536694040
CAS-No.
7439-92-1
REACH Candidate List Substance
Lead
RoHS Compliance Status
Compliant,With Exemption
RoHS Exemption
6(c)
SCIP notification number (Austria)
e0425b94-7f42-4cbd-87ad-6b58edf5de7b
SCIP notification number (Belgium)
8089753f-0b85-4ff0-ad2f-5e08b15c1f64
SCIP notification number (Bulgaria)
a1bec08d-32bc-4a20-b4c5-ed701483023e
SCIP notification number (Czech Republic)
b8ae6017-b252-401f-bfc1-423a40847a03
SCIP notification number (Denmark)
34ce183d-3c59-4db7-baec-52143dbd7e4d
SCIP notification number (Finland)
6a4b7425-2576-4ee9-a983-51b4753ed982
SCIP notification number (France)
c66b91b4-2e5e-4aab-9776-0f4fa7f20c58
SCIP notification number (Germany)
f101f04c-317d-4c90-b38c-9e8fca0e2df2
SCIP notification number (Hungary)
e3e99ee1-9be1-408d-b1d1-63d542331445
SCIP notification number (Italy)
9992a5c3-0038-4b01-b5ef-57efdf14cab1
SCIP notification number (Netherlands)
2645b2f2-f02e-4d7c-b506-2c6f5ea9c27f
SCIP notification number (Poland)
b6824de0-ff78-4e11-aa97-eddbf824fcbd
SCIP notification number (Romania)
481d2fde-1556-42c3-9a0e-f1d41f6bd5a3
SCIP notification number (Sweden)
245a7b9a-2eec-4531-bf1f-508ef55385af
Ratings per
IEC/EN 60664-1
Rated voltage (III / 3)
250V
Rated impulse voltage (III / 3)
4kV
Rated voltage (III/2)
320V
Rated surge voltage (III/2)
4kV
Nominal voltage (II/2)
630V
Rated surge voltage (II/2)
4kV
Rated current
16A
Legend (ratings)
(III / 2) ? Overvoltage category III / Pollution degree 2
Approvals per
CSA
Rated voltage UL (Use Group B)
300V
Rated current UL (Use Group B)
15A
Rated voltage UL (Use Group D)
300V
Rated current UL (Use Group D)
10A
Rated voltage (UL 1977)
600V
Rated current UL 1977
15A
Rated voltage CSA (Use Group B)
300V
Rated current CSA (Use Group B)
15A
Rated voltage CSA (Use Group D)
300V
Rated current CSA (Use Group D)
10A
Number of poles
5
Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment
DIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests
DIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation location
Service life test, Category?1, Class?A/B
Function test with noise-like vibration
Test passed according to Section 8 of the standard
Frequency
f1= 5 Hz to f2= 150 Hz
Acceleration
5g (highest test level used for all axes)
Test duration per axis
5 h
Test directions
X, Y and Z axes
Monitoring for contact faults/interruptions
Passed
Voltage drop measurement before and after each axis
Passed
Simulated service life test through increased levels of noise-like vibration
Test passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptions
Passed
Extended test scope: Voltage drop measurement before and after each axis
Passed
Shock test
Test passed according to Section 10 of the standard
Shock form
Half sine
Shock duration
30 ms
Number of shocks per axis
3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipment
Passed