Product Model
231-365/108-000

Selling Points
- 1High Current Rating: Supports up to 16A current, ideal for stable and efficient connections.
- 2Durable Design: Constructed with electro-copper contacts and polyamide insulation for long-lasting performance.
- 3Easy Installation: Straight and threaded flange design ensures secure mounting on PCBs.
- 4Safety Features: Includes anti-rotation protection and no mismating protection for safe operation.
- 5Compliant with Standards: Meets IEC/EN, UL, and CSA standards for overvoltage and surge protection.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Safety information | TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated. | Variants: | Other pole numbers |
Total number of potentials | 5 | Number of connection types | 1 |
Number of levels | 1 | Pin spacing | 5.08?mm?/ 0.2?inches |
Width | 35.4?mm?/ 1.394?inches | Height | 17?mm?/ 0.669?inches |
Height from the surface | 12?mm?/ 0.472?inches | Depth | 8.4?mm?/ 0.331?inches |
Solder pin length | 5mm | Solder pin dimensions | 1.2 x 1.2?mm |
Drilled hole diameter with tolerance | 1.7(+0.1)mm | Variable coding | Yes |
Anti-rotation protection | Yes | Contact type (pluggable connector) | Male connector/plug |
Connector (connection type) | for PCB | Mismating protection | No |
Plugging without loss of pin spacing | No | Mating direction to the PCB | 90° |
Locking of plug-in connection | Threaded flange | PCB contact | THT |
Solder pin arrangement | over the entire male connector (in-line) | Number of solder pins per potential | 1 |
Note (material data) | Information on material specifications can be found here | Color | orange |
Material group | I | Insulation material (main housing) | Polyamide (PA66) |
Flammability class per UL94 | V0 | Contact material | Electrolytic copper (ECu) |
Contact plating | Tin | Fire load | 0.042MJ |
Weight | 2.7g | Limit temperature range | -60 … +100?°C |
Processing temperature | -35 … +60?°C | Product Group | 3 (Multi Conn. System) |
eCl@ss 10.0 | 27-44-04-02 | eCl@ss 9.0 | 27-44-04-02 |
ETIM 9.0 | EC002637 | ETIM 8.0 | EC002637 |
ECCN | NO US CLASSIFICATION | PU (SPU) | 100?pcs |
Packaging type | box | Country of origin | PL |
GTIN | 4045454845650 | Customs tariff number | 8536694040 |
CAS-No. | 7439-92-1 | REACH Candidate List Substance | Lead |
RoHS Compliance Status | Compliant,With Exemption | RoHS Exemption | 6(c) |
SCIP notification number (Austria) | e0425b94-7f42-4cbd-87ad-6b58edf5de7b | SCIP notification number (Belgium) | 8089753f-0b85-4ff0-ad2f-5e08b15c1f64 |
SCIP notification number (Bulgaria) | a1bec08d-32bc-4a20-b4c5-ed701483023e | SCIP notification number (Czech Republic) | b8ae6017-b252-401f-bfc1-423a40847a03 |
SCIP notification number (Denmark) | 34ce183d-3c59-4db7-baec-52143dbd7e4d | SCIP notification number (Finland) | 6a4b7425-2576-4ee9-a983-51b4753ed982 |
SCIP notification number (France) | c66b91b4-2e5e-4aab-9776-0f4fa7f20c58 | SCIP notification number (Germany) | f101f04c-317d-4c90-b38c-9e8fca0e2df2 |
SCIP notification number (Hungary) | e3e99ee1-9be1-408d-b1d1-63d542331445 | SCIP notification number (Italy) | 9992a5c3-0038-4b01-b5ef-57efdf14cab1 |
SCIP notification number (Netherlands) | 2645b2f2-f02e-4d7c-b506-2c6f5ea9c27f | SCIP notification number (Poland) | b6824de0-ff78-4e11-aa97-eddbf824fcbd |
SCIP notification number (Romania) | 481d2fde-1556-42c3-9a0e-f1d41f6bd5a3 | SCIP notification number (Sweden) | 245a7b9a-2eec-4531-bf1f-508ef55385af |
Ratings per | IEC/EN 60664-1 | Rated voltage (III / 3) | 250V |
Rated impulse voltage (III / 3) | 4kV | Rated voltage (III/2) | 320V |
Rated surge voltage (III/2) | 4kV | Nominal voltage (II/2) | 630V |
Rated surge voltage (II/2) | 4kV | Rated current | 16A |
Legend (ratings) | (III / 2) ? Overvoltage category III / Pollution degree 2 | Approvals per | CSA |
Rated voltage UL (Use Group B) | 300V | Rated current UL (Use Group B) | 15A |
Rated voltage UL (Use Group D) | 300V | Rated current UL (Use Group D) | 10A |
Rated voltage (UL 1977) | 600V | Rated current UL 1977 | 15A |
Rated voltage CSA (Use Group B) | 300V | Rated current CSA (Use Group B) | 15A |
Rated voltage CSA (Use Group D) | 300V | Rated current CSA (Use Group D) | 10A |
Number of poles | 5 | Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment | DIN EN 50155 (VDE 0115-200):2022-06 |
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests | DIN EN 61373 (VDE 0115-0106):2011-04 | Spectrum/Installation location | Service life test, Category?1, Class?A/B |
Function test with noise-like vibration | Test passed according to Section 8 of the standard | Frequency | f1= 5 Hz to f2= 150 Hz |
Acceleration | 5g (highest test level used for all axes) | Test duration per axis | 5 h |
Test directions | X, Y and Z axes | Monitoring for contact faults/interruptions | Passed |
Voltage drop measurement before and after each axis | Passed | Simulated service life test through increased levels of noise-like vibration | Test passed according to Section 9 of the standard |
Extended test scope: Monitoring for contact faults/interruptions | Passed | Extended test scope: Voltage drop measurement before and after each axis | Passed |
Shock test | Test passed according to Section 10 of the standard | Shock form | Half sine |
Shock duration | 30 ms | Number of shocks per axis | 3 pos. und 3 neg. |
Vibration and shock stress for rolling stock equipment | Passed |
Specifications may be subject to change without notice