Selling Points

  • 1Designed without breaking capacity for compliance with DIN EN 61984.
  • 2Angled and threaded flange for secure PCB mounting.
  • 35-pole, 1.0 x 1.0 mm solder pin with pin spacing of 5.08 mm.
  • 4Rated voltage up to 320 V and impulse voltage up to 4 kV.
  • 5Compatible with various PCB design software including TARGET, EAGLE, and DesignSpark.
Product Details
231-535/108-000
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Safety information
TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated.
Variants:
Other pole numbers
Total number of potentials
5
Number of connection types
1
Number of levels
1
Pin spacing
5.08?mm?/ 0.2?inches
Width
35.4?mm?/ 1.394?inches
Height
12.2?mm?/ 0.48?inches
Height from the surface
8.4?mm?/ 0.331?inches
Depth
12?mm?/ 0.472?inches
Solder pin length
3.8mm
Solder pin dimensions
1 x 1?mm
Drilled hole diameter with tolerance
1.4(+0.1)mm
Variable coding
Yes
Anti-rotation protection
Yes
Contact type (pluggable connector)
Male connector/plug
Connector (connection type)
for PCB
Mismating protection
No
Plugging without loss of pin spacing
No
Mating direction to the PCB
Locking of plug-in connection
Threaded flange
PCB contact
THT
Solder pin arrangement
over the entire male connector (in-line)
Number of solder pins per potential
1
Note (material data)
Information on material specifications can be found here
Color
orange
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Contact material
Electrolytic copper (ECu)
Contact plating
Tin
Fire load
0.042MJ
Weight
2.4g
Limit temperature range
-60 … +100?°C
Processing temperature
-35 … +60?°C
Product Group
3 (Multi Conn. System)
eCl@ss 10.0
27-44-04-02
eCl@ss 9.0
27-44-04-02
ETIM 9.0
EC002637
ETIM 8.0
EC002637
ECCN
NO US CLASSIFICATION
PU (SPU)
100?pcs
Packaging type
box
Country of origin
PL
GTIN
4044918866958
Customs tariff number
8536694040
CAS-No.
7439-92-1
REACH Candidate List Substance
Lead
RoHS Compliance Status
Compliant,With Exemption
RoHS Exemption
6(c)
SCIP notification number (Austria)
efe066f0-af6f-4bb6-95b1-5e81e8f47528
SCIP notification number (Belgium)
28e39789-9b3b-4cad-9fdf-568a0da42a29
SCIP notification number (Bulgaria)
73f693a1-fd75-424f-8579-d1b64aed7f49
SCIP notification number (Czech Republic)
f1f7bb73-76ed-4c28-b7f0-c79aac65073f
SCIP notification number (Denmark)
587924c5-1d37-4bbb-a612-961e987cca72
SCIP notification number (Finland)
c618e9d0-b9e0-4ed0-839d-9928c24ef575
SCIP notification number (France)
18c4cbdc-6b7c-4f3e-b0e9-e11e9458201e
SCIP notification number (Germany)
f511c45b-2f90-4d48-9594-015698fbaf4b
SCIP notification number (Hungary)
30ef404a-e043-4f2e-a514-4c638048500e
SCIP notification number (Italy)
804812e0-016c-4603-8e80-6b36fe40bd21
SCIP notification number (Netherlands)
89131cc8-9daf-4022-b8e6-6b65c31a47d2
SCIP notification number (Poland)
5e6d255d-1da9-44f6-9218-ec787f75d74e
SCIP notification number (Romania)
04167e8f-a5eb-4d50-b21b-3a927b2eac37
SCIP notification number (Sweden)
679ce1a7-d028-403b-b799-295fc330cb6f
Ratings per
IEC/EN 60664-1
Rated voltage (III / 3)
320V
Rated impulse voltage (III / 3)
4kV
Rated voltage (III/2)
320V
Rated surge voltage (III/2)
4kV
Nominal voltage (II/2)
630V
Rated surge voltage (II/2)
4kV
Rated current
12A
Legend (ratings)
(III / 2) ? Overvoltage category III / Pollution degree 2
Approvals per
CSA
Rated voltage UL (Use Group B)
300V
Rated current UL (Use Group B)
10A
Rated voltage UL (Use Group D)
300V
Rated current UL (Use Group D)
10A
Rated voltage (UL 1977)
600V
Rated current UL 1977
10A
Rated voltage CSA (Use Group B)
300V
Rated current CSA (Use Group B)
10A
Rated voltage CSA (Use Group D)
300V
Rated current CSA (Use Group D)
10A
Number of poles
5
Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment
DIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests
DIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation location
Service life test, Category?1, Class?A/B
Function test with noise-like vibration
Test passed according to Section 8 of the standard
Frequency
f1= 5 Hz to f2= 150 Hz
Acceleration
5g (highest test level used for all axes)
Test duration per axis
5 h
Test directions
X, Y and Z axes
Monitoring for contact faults/interruptions
Passed
Voltage drop measurement before and after each axis
Passed
Simulated service life test through increased levels of noise-like vibration
Test passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptions
Passed
Extended test scope: Voltage drop measurement before and after each axis
Passed
Shock test
Test passed according to Section 10 of the standard
Shock form
Half sine
Shock duration
30 ms
Number of shocks per axis
3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipment
Passed

Specifications may be subject to change without notice