Product Model

231-562/108-000

In Stock
Last updated: 2025/4/18
wago 231-562/108-000

Selling Points

  • 1Made from durable polyamide 66 (PA 66) and electrolytic copper with tin-plated contact surfaces.
  • 2Supports nominal current up to 16 A, ensuring stable connections in various applications.
  • 3Angled solder pins and threaded flange facilitate horizontal or vertical PCB mounting.
  • 4Meets IEC/EN 60664-1 and UL 1059 standards, with overvoltage category III and pollution degree 2 ratings.
  • 5Compatible with DesignSpark, EAGLE, and TARGET PCB design software for seamless integration.
Product Details
231-562/108-000
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Safety information
TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated.
Variants:
Other pole numbers
Total number of potentials
2
Number of connection types
1
Number of levels
1
Pin spacing
5.08?mm?/ 0.2?inches
Width
20.16?mm?/ 0.794?inches
Height
12.2?mm?/ 0.48?inches
Height from the surface
8.4?mm?/ 0.331?inches
Depth
12?mm?/ 0.472?inches
Solder pin length
3.8mm
Solder pin dimensions
1.2 x 1.2?mm
Drilled hole diameter with tolerance
1.7(+0.1)mm
Variable coding
Yes
Anti-rotation protection
Yes
Contact type (pluggable connector)
Male connector/plug
Connector (connection type)
for PCB
Mismating protection
No
Plugging without loss of pin spacing
No
Mating direction to the PCB
Locking of plug-in connection
Threaded flange
PCB contact
THT
Solder pin arrangement
over the entire male connector (in-line)
Number of solder pins per potential
1
Note (material data)
Information on material specifications can be found here
Color
orange
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Contact material
Electrolytic copper (ECu)
Contact plating
Tin
Fire load
0.026MJ
Weight
1.6g
Limit temperature range
-60 … +100?°C
Processing temperature
-35 … +60?°C
Product Group
3 (Multi Conn. System)
eCl@ss 10.0
27-44-04-02
eCl@ss 9.0
27-44-04-02
ETIM 9.0
EC002637
ETIM 8.0
EC002637
ECCN
NO US CLASSIFICATION
PU (SPU)
100?pcs
Packaging type
box
Country of origin
DE
GTIN
4045454843717
Customs tariff number
8536694040
CAS-No.
7439-92-1
REACH Candidate List Substance
Lead
RoHS Compliance Status
Compliant,With Exemption
RoHS Exemption
6(c)
SCIP notification number (Austria)
0d3280fa-1749-4d9e-9648-c399d60d2b78
SCIP notification number (Belgium)
65be087b-ae4a-437d-9fff-7bb8dfa5f6e6
SCIP notification number (Bulgaria)
a1e3e355-141f-49ef-b16d-8dbbd055dd44
SCIP notification number (Czech Republic)
ecf0abdb-eb7a-4c9f-858c-0e08cb8035c4
SCIP notification number (Denmark)
3bc91f2d-987e-4ff0-9fb7-5d7129bd6a47
SCIP notification number (Finland)
38e0d155-5172-49b3-83c4-41c67f6f24dc
SCIP notification number (France)
f5f5802e-51d0-45e3-a4f2-f6608faf325f
SCIP notification number (Germany)
24e77486-5b8a-4f5c-89a4-e9b462380cba
SCIP notification number (Hungary)
57d7d746-dca7-4c72-b03a-659772a17997
SCIP notification number (Italy)
7ef4e1b2-d2f6-4eb7-9db6-0a80e1a6cbac
SCIP notification number (Netherlands)
dae6995e-42cc-4f55-af9e-6b60cbd941f1
SCIP notification number (Poland)
fec1815a-fb1b-44e1-9b68-054295607716
SCIP notification number (Romania)
90debd39-ea55-471d-8138-2139963738c6
SCIP notification number (Sweden)
083a10f1-1468-4ae8-8ddf-b65290a56374
Ratings per
IEC/EN 60664-1
Rated voltage (III / 3)
250V
Rated impulse voltage (III / 3)
4kV
Rated voltage (III/2)
320V
Rated surge voltage (III/2)
4kV
Nominal voltage (II/2)
630V
Rated surge voltage (II/2)
4kV
Rated current
16A
Legend (ratings)
(III / 2) ? Overvoltage category III / Pollution degree 2
Approvals per
CSA
Rated voltage UL (Use Group B)
300V
Rated current UL (Use Group B)
15A
Rated voltage UL (Use Group D)
300V
Rated current UL (Use Group D)
10A
Rated voltage (UL 1977)
600V
Rated current UL 1977
15A
Rated voltage CSA (Use Group B)
300V
Rated current CSA (Use Group B)
15A
Rated voltage CSA (Use Group D)
300V
Rated current CSA (Use Group D)
10A
Number of poles
2
Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment
DIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests
DIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation location
Service life test, Category?1, Class?A/B
Function test with noise-like vibration
Test passed according to Section 8 of the standard
Frequency
f1= 5 Hz to f2= 150 Hz
Acceleration
5g (highest test level used for all axes)
Test duration per axis
5 h
Test directions
X, Y and Z axes
Monitoring for contact faults/interruptions
Passed
Voltage drop measurement before and after each axis
Passed
Simulated service life test through increased levels of noise-like vibration
Test passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptions
Passed
Extended test scope: Voltage drop measurement before and after each axis
Passed
Shock test
Test passed according to Section 10 of the standard
Shock form
Half sine
Shock duration
30 ms
Number of shocks per axis
3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipment
Passed

Specifications may be subject to change without notice