Product Model

231-568/108-000

In Stock
Last updated: 2025/4/19
wago 231-568/108-000

Selling Points

  • 1Reliable and Efficient: Known for its high standards of performance and safety.
  • 2Easy Installation: Designed for quick and secure connections.
  • 3Robust Construction: Made with durable materials for long-lasting use.
  • 4Angled Design: Facilitates easier access to pins during soldering.
  • 5Rugged and Maintenance-Free: Ideal for demanding industrial environments.
Product Details
231-568/108-000
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Safety information
TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated.
Variants:
Other pole numbers
Total number of potentials
8
Number of connection types
1
Number of levels
1
Pin spacing
5.08?mm?/ 0.2?inches
Width
50.64?mm?/ 1.994?inches
Height
12.2?mm?/ 0.48?inches
Height from the surface
8.4?mm?/ 0.331?inches
Depth
12?mm?/ 0.472?inches
Solder pin length
3.8mm
Solder pin dimensions
1.2 x 1.2?mm
Drilled hole diameter with tolerance
1.7(+0.1)mm
Variable coding
Yes
Anti-rotation protection
Yes
Contact type (pluggable connector)
Male connector/plug
Connector (connection type)
for PCB
Mismating protection
No
Plugging without loss of pin spacing
No
Mating direction to the PCB
Locking of plug-in connection
Threaded flange
PCB contact
THT
Solder pin arrangement
over the entire male connector (in-line)
Number of solder pins per potential
1
Note (material data)
Information on material specifications can be found here
Color
orange
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Contact material
Electrolytic copper (ECu)
Contact plating
Tin
Fire load
0.058MJ
Weight
3.8g
Limit temperature range
-60 … +100?°C
Processing temperature
-35 … +60?°C
Product Group
3 (Multi Conn. System)
eCl@ss 10.0
27-44-04-02
eCl@ss 9.0
27-44-04-02
ETIM 9.0
EC002637
ETIM 8.0
EC002637
ECCN
NO US CLASSIFICATION
PU (SPU)
100?pcs
Packaging type
box
Country of origin
PL
GTIN
4045454845438
Customs tariff number
8536694040
CAS-No.
7439-92-1
REACH Candidate List Substance
Lead
RoHS Compliance Status
Compliant,With Exemption
RoHS Exemption
6(c)
SCIP notification number (Austria)
878a4f52-08df-466e-bbb4-7fdaf5e87aed
SCIP notification number (Belgium)
de736b30-10af-4302-8e52-731eeefd3420
SCIP notification number (Bulgaria)
4b7061d8-d9ab-4232-8930-4d84b3d3abcc
SCIP notification number (Czech Republic)
ddbd08fa-ff7b-45de-8f59-d44988024514
SCIP notification number (Denmark)
5550dfe4-9cc9-4769-9d74-2dc2a69616ef
SCIP notification number (Finland)
b6db6ea7-07b4-4e47-b91c-6645dbc849fd
SCIP notification number (France)
085992de-17e9-4fcf-90e1-87f4b5ad3f74
SCIP notification number (Germany)
08b677b3-bdcf-4e13-8a4b-b61d4beb783a
SCIP notification number (Hungary)
7a666203-0d60-406d-9587-c8496eb020cc
SCIP notification number (Italy)
50046d7d-7f2f-41b9-8d99-1bbfda8fbf3b
SCIP notification number (Netherlands)
655118fb-9dc7-43cd-838b-193d5913c007
SCIP notification number (Poland)
4f626720-79f4-415e-bad9-72590d722d49
SCIP notification number (Romania)
f374c303-b477-403b-a704-f0fccdfe3a74
SCIP notification number (Sweden)
e6dd1153-cfa5-45bb-8bd6-48a77eb65ead
Ratings per
IEC/EN 60664-1
Rated voltage (III / 3)
250V
Rated impulse voltage (III / 3)
4kV
Rated voltage (III/2)
320V
Rated surge voltage (III/2)
4kV
Nominal voltage (II/2)
630V
Rated surge voltage (II/2)
4kV
Rated current
16A
Legend (ratings)
(III / 2) ? Overvoltage category III / Pollution degree 2
Approvals per
CSA
Rated voltage UL (Use Group B)
300V
Rated current UL (Use Group B)
15A
Rated voltage UL (Use Group D)
300V
Rated current UL (Use Group D)
10A
Rated voltage (UL 1977)
600V
Rated current UL 1977
15A
Rated voltage CSA (Use Group B)
300V
Rated current CSA (Use Group B)
15A
Rated voltage CSA (Use Group D)
300V
Rated current CSA (Use Group D)
10A
Number of poles
8
Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment
DIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests
DIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation location
Service life test, Category?1, Class?A/B
Function test with noise-like vibration
Test passed according to Section 8 of the standard
Frequency
f1= 5 Hz to f2= 150 Hz
Acceleration
5g (highest test level used for all axes)
Test duration per axis
5 h
Test directions
X, Y and Z axes
Monitoring for contact faults/interruptions
Passed
Voltage drop measurement before and after each axis
Passed
Simulated service life test through increased levels of noise-like vibration
Test passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptions
Passed
Extended test scope: Voltage drop measurement before and after each axis
Passed
Shock test
Test passed according to Section 10 of the standard
Shock form
Half sine
Shock duration
30 ms
Number of shocks per axis
3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipment
Passed

Specifications may be subject to change without notice