Product Model
231-568/108-000

Selling Points
- 1Reliable and Efficient: Known for its high standards of performance and safety.
- 2Easy Installation: Designed for quick and secure connections.
- 3Robust Construction: Made with durable materials for long-lasting use.
- 4Angled Design: Facilitates easier access to pins during soldering.
- 5Rugged and Maintenance-Free: Ideal for demanding industrial environments.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Safety information | TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated. | Variants: | Other pole numbers |
Total number of potentials | 8 | Number of connection types | 1 |
Number of levels | 1 | Pin spacing | 5.08?mm?/ 0.2?inches |
Width | 50.64?mm?/ 1.994?inches | Height | 12.2?mm?/ 0.48?inches |
Height from the surface | 8.4?mm?/ 0.331?inches | Depth | 12?mm?/ 0.472?inches |
Solder pin length | 3.8mm | Solder pin dimensions | 1.2 x 1.2?mm |
Drilled hole diameter with tolerance | 1.7(+0.1)mm | Variable coding | Yes |
Anti-rotation protection | Yes | Contact type (pluggable connector) | Male connector/plug |
Connector (connection type) | for PCB | Mismating protection | No |
Plugging without loss of pin spacing | No | Mating direction to the PCB | 0° |
Locking of plug-in connection | Threaded flange | PCB contact | THT |
Solder pin arrangement | over the entire male connector (in-line) | Number of solder pins per potential | 1 |
Note (material data) | Information on material specifications can be found here | Color | orange |
Material group | I | Insulation material (main housing) | Polyamide (PA66) |
Flammability class per UL94 | V0 | Contact material | Electrolytic copper (ECu) |
Contact plating | Tin | Fire load | 0.058MJ |
Weight | 3.8g | Limit temperature range | -60 … +100?°C |
Processing temperature | -35 … +60?°C | Product Group | 3 (Multi Conn. System) |
eCl@ss 10.0 | 27-44-04-02 | eCl@ss 9.0 | 27-44-04-02 |
ETIM 9.0 | EC002637 | ETIM 8.0 | EC002637 |
ECCN | NO US CLASSIFICATION | PU (SPU) | 100?pcs |
Packaging type | box | Country of origin | PL |
GTIN | 4045454845438 | Customs tariff number | 8536694040 |
CAS-No. | 7439-92-1 | REACH Candidate List Substance | Lead |
RoHS Compliance Status | Compliant,With Exemption | RoHS Exemption | 6(c) |
SCIP notification number (Austria) | 878a4f52-08df-466e-bbb4-7fdaf5e87aed | SCIP notification number (Belgium) | de736b30-10af-4302-8e52-731eeefd3420 |
SCIP notification number (Bulgaria) | 4b7061d8-d9ab-4232-8930-4d84b3d3abcc | SCIP notification number (Czech Republic) | ddbd08fa-ff7b-45de-8f59-d44988024514 |
SCIP notification number (Denmark) | 5550dfe4-9cc9-4769-9d74-2dc2a69616ef | SCIP notification number (Finland) | b6db6ea7-07b4-4e47-b91c-6645dbc849fd |
SCIP notification number (France) | 085992de-17e9-4fcf-90e1-87f4b5ad3f74 | SCIP notification number (Germany) | 08b677b3-bdcf-4e13-8a4b-b61d4beb783a |
SCIP notification number (Hungary) | 7a666203-0d60-406d-9587-c8496eb020cc | SCIP notification number (Italy) | 50046d7d-7f2f-41b9-8d99-1bbfda8fbf3b |
SCIP notification number (Netherlands) | 655118fb-9dc7-43cd-838b-193d5913c007 | SCIP notification number (Poland) | 4f626720-79f4-415e-bad9-72590d722d49 |
SCIP notification number (Romania) | f374c303-b477-403b-a704-f0fccdfe3a74 | SCIP notification number (Sweden) | e6dd1153-cfa5-45bb-8bd6-48a77eb65ead |
Ratings per | IEC/EN 60664-1 | Rated voltage (III / 3) | 250V |
Rated impulse voltage (III / 3) | 4kV | Rated voltage (III/2) | 320V |
Rated surge voltage (III/2) | 4kV | Nominal voltage (II/2) | 630V |
Rated surge voltage (II/2) | 4kV | Rated current | 16A |
Legend (ratings) | (III / 2) ? Overvoltage category III / Pollution degree 2 | Approvals per | CSA |
Rated voltage UL (Use Group B) | 300V | Rated current UL (Use Group B) | 15A |
Rated voltage UL (Use Group D) | 300V | Rated current UL (Use Group D) | 10A |
Rated voltage (UL 1977) | 600V | Rated current UL 1977 | 15A |
Rated voltage CSA (Use Group B) | 300V | Rated current CSA (Use Group B) | 15A |
Rated voltage CSA (Use Group D) | 300V | Rated current CSA (Use Group D) | 10A |
Number of poles | 8 | Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment | DIN EN 50155 (VDE 0115-200):2022-06 |
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests | DIN EN 61373 (VDE 0115-0106):2011-04 | Spectrum/Installation location | Service life test, Category?1, Class?A/B |
Function test with noise-like vibration | Test passed according to Section 8 of the standard | Frequency | f1= 5 Hz to f2= 150 Hz |
Acceleration | 5g (highest test level used for all axes) | Test duration per axis | 5 h |
Test directions | X, Y and Z axes | Monitoring for contact faults/interruptions | Passed |
Voltage drop measurement before and after each axis | Passed | Simulated service life test through increased levels of noise-like vibration | Test passed according to Section 9 of the standard |
Extended test scope: Monitoring for contact faults/interruptions | Passed | Extended test scope: Voltage drop measurement before and after each axis | Passed |
Shock test | Test passed according to Section 10 of the standard | Shock form | Half sine |
Shock duration | 30 ms | Number of shocks per axis | 3 pos. und 3 neg. |
Vibration and shock stress for rolling stock equipment | Passed |
Specifications may be subject to change without notice