Product Model
231-569/108-000

Selling Points
- 1High-quality construction for reliable performance.
- 2Compatible with a range of systems for seamless integration.
- 3Angled design with 1.2 x 1.2 mm solder pins for efficient connectivity.
- 4Threaded flange for secure mounting on PCBs.
- 59-pole configuration with 5.08 mm pin spacing for versatile applications.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Safety information | TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated. | Variants: | Other pole numbers |
Total number of potentials | 9 | Number of connection types | 1 |
Number of levels | 1 | Pin spacing | 5.08?mm?/ 0.2?inches |
Width | 55.72?mm?/ 2.194?inches | Height | 12.2?mm?/ 0.48?inches |
Height from the surface | 8.4?mm?/ 0.331?inches | Depth | 12?mm?/ 0.472?inches |
Solder pin length | 3.8mm | Solder pin dimensions | 1.2 x 1.2?mm |
Drilled hole diameter with tolerance | 1.7(+0.1)mm | Variable coding | Yes |
Anti-rotation protection | Yes | Contact type (pluggable connector) | Male connector/plug |
Connector (connection type) | for PCB | Mismating protection | No |
Plugging without loss of pin spacing | No | Mating direction to the PCB | 0° |
Locking of plug-in connection | Threaded flange | PCB contact | THT |
Solder pin arrangement | over the entire male connector (in-line) | Number of solder pins per potential | 1 |
Note (material data) | Information on material specifications can be found here | Color | orange |
Material group | I | Insulation material (main housing) | Polyamide (PA66) |
Flammability class per UL94 | V0 | Contact material | Electrolytic copper (ECu) |
Contact plating | Tin | Fire load | 0.063MJ |
Weight | 4.2g | Limit temperature range | -60 … +100?°C |
Processing temperature | -35 … +60?°C | Product Group | 3 (Multi Conn. System) |
eCl@ss 10.0 | 27-44-04-02 | eCl@ss 9.0 | 27-44-04-02 |
ETIM 9.0 | EC002637 | ETIM 8.0 | EC002637 |
ECCN | NO US CLASSIFICATION | PU (SPU) | 100?pcs |
Packaging type | box | Country of origin | PL |
GTIN | 4045454845445 | Customs tariff number | 8536694040 |
CAS-No. | 7439-92-1 | REACH Candidate List Substance | Lead |
RoHS Compliance Status | Compliant,With Exemption | RoHS Exemption | 6(c) |
SCIP notification number (Austria) | 20289996-7b21-4741-8b40-15b2f0ea8f24 | SCIP notification number (Belgium) | a39d2b86-ed32-4f8a-8b1e-1d665cd0beaf |
SCIP notification number (Bulgaria) | 188811a1-78c3-48b9-9b26-57c4314845c9 | SCIP notification number (Czech Republic) | b48f0c44-7304-4c9a-8783-a72f1890ecd6 |
SCIP notification number (Denmark) | bffc13c5-dd96-4bde-95a4-ec5ee2247451 | SCIP notification number (Finland) | 79f1506f-a894-4497-9301-fdafac7e85f1 |
SCIP notification number (France) | a4a7a2e8-bae0-4312-8167-462229c3bda1 | SCIP notification number (Germany) | 1e9e6b47-672d-48d9-9e2e-f5b145695dac |
SCIP notification number (Hungary) | 0f0a485e-f05b-4b2b-9799-4e3756af88ad | SCIP notification number (Italy) | eb69a57c-ac67-408d-970d-92fc8cee4c67 |
SCIP notification number (Netherlands) | 89b805f9-bc75-442f-8f0c-a0c3294c736e | SCIP notification number (Poland) | 16aa0b82-24ef-4bda-b047-4532329a3591 |
SCIP notification number (Romania) | 9b00aed0-9655-4cce-a61d-a446d2eb399b | SCIP notification number (Sweden) | 955b34b6-3e0a-4027-9824-de70c5a5f7cb |
Ratings per | IEC/EN 60664-1 | Rated voltage (III / 3) | 250V |
Rated impulse voltage (III / 3) | 4kV | Rated voltage (III/2) | 320V |
Rated surge voltage (III/2) | 4kV | Nominal voltage (II/2) | 630V |
Rated surge voltage (II/2) | 4kV | Rated current | 16A |
Legend (ratings) | (III / 2) ? Overvoltage category III / Pollution degree 2 | Approvals per | CSA |
Rated voltage UL (Use Group B) | 300V | Rated current UL (Use Group B) | 15A |
Rated voltage UL (Use Group D) | 300V | Rated current UL (Use Group D) | 10A |
Rated voltage (UL 1977) | 600V | Rated current UL 1977 | 15A |
Rated voltage CSA (Use Group B) | 300V | Rated current CSA (Use Group B) | 15A |
Rated voltage CSA (Use Group D) | 300V | Rated current CSA (Use Group D) | 10A |
Number of poles | 9 | Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment | DIN EN 50155 (VDE 0115-200):2022-06 |
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests | DIN EN 61373 (VDE 0115-0106):2011-04 | Spectrum/Installation location | Service life test, Category?1, Class?A/B |
Function test with noise-like vibration | Test passed according to Section 8 of the standard | Frequency | f1= 5 Hz to f2= 150 Hz |
Acceleration | 5g (highest test level used for all axes) | Test duration per axis | 5 h |
Test directions | X, Y and Z axes | Monitoring for contact faults/interruptions | Passed |
Voltage drop measurement before and after each axis | Passed | Simulated service life test through increased levels of noise-like vibration | Test passed according to Section 9 of the standard |
Extended test scope: Monitoring for contact faults/interruptions | Passed | Extended test scope: Voltage drop measurement before and after each axis | Passed |
Shock test | Test passed according to Section 10 of the standard | Shock form | Half sine |
Shock duration | 30 ms | Number of shocks per axis | 3 pos. und 3 neg. |
Vibration and shock stress for rolling stock equipment | Passed |
Specifications may be subject to change without notice