Product Model

231-570/108-000

In Stock
Last updated: 2025/4/19
wago 231-570/108-000

Selling Points

  • 110-Pole Configuration: Ideal for complex PCB connections with 10 poles.
  • 2Angled Design: Enhances stability and ease of use with angled solder pins.
  • 3High Current Rating: Supports nominal current up to 16 A, ensuring reliable performance.
  • 4UL and CSA Certified: Meets stringent safety standards with UL 1059 and CSA approvals.
  • 5Durable Construction: Made from high-quality electrolytic copper with tin plating for long-lasting use.
Product Details
231-570/108-000
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Safety information
TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated.
Variants:
Other pole numbers
Total number of potentials
10
Number of connection types
1
Number of levels
1
Pin spacing
5.08?mm?/ 0.2?inches
Width
60.8?mm?/ 2.394?inches
Height
12.2?mm?/ 0.48?inches
Height from the surface
8.4?mm?/ 0.331?inches
Depth
12?mm?/ 0.472?inches
Solder pin length
3.8mm
Solder pin dimensions
1.2 x 1.2?mm
Drilled hole diameter with tolerance
1.7(+0.1)mm
Variable coding
Yes
Anti-rotation protection
Yes
Contact type (pluggable connector)
Male connector/plug
Connector (connection type)
for PCB
Mismating protection
No
Plugging without loss of pin spacing
No
Mating direction to the PCB
Locking of plug-in connection
Threaded flange
PCB contact
THT
Solder pin arrangement
over the entire male connector (in-line)
Number of solder pins per potential
1
Note (material data)
Information on material specifications can be found here
Color
orange
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Contact material
Electrolytic copper (ECu)
Contact plating
Tin
Fire load
0.068MJ
Weight
4.5g
Limit temperature range
-60 … +100?°C
Processing temperature
-35 … +60?°C
Product Group
3 (Multi Conn. System)
eCl@ss 10.0
27-44-04-02
eCl@ss 9.0
27-44-04-02
ETIM 9.0
EC002637
ETIM 8.0
EC002637
ECCN
NO US CLASSIFICATION
PU (SPU)
100?pcs
Packaging type
box
Country of origin
PL
GTIN
4045454845452
Customs tariff number
8536694040
CAS-No.
7439-92-1
REACH Candidate List Substance
Lead
RoHS Compliance Status
Compliant,With Exemption
RoHS Exemption
6(c)
SCIP notification number (Austria)
9149cebf-a029-4709-82d5-ccac170002b1
SCIP notification number (Belgium)
63eb43c7-3b36-4bc7-8358-962234276c1e
SCIP notification number (Bulgaria)
aef69f7b-a324-434a-8a21-cc7702bdfe75
SCIP notification number (Czech Republic)
297e3eff-aee8-4b47-8488-ca6cae18448b
SCIP notification number (Denmark)
04437782-64b3-4ef0-8bcc-8bb12fa980b5
SCIP notification number (Finland)
bf705e35-464b-44dd-b2ac-e5d87bd25133
SCIP notification number (France)
be6de23f-e88e-4095-9b1c-b54e632caff5
SCIP notification number (Germany)
1b350784-5e5e-4e37-971b-48af05b63703
SCIP notification number (Hungary)
371c44a1-c46f-41a9-b108-4f38015fd2c1
SCIP notification number (Italy)
c820215e-3bc3-4930-8b2d-f96d624f7ecb
SCIP notification number (Netherlands)
9a88e6c6-5a41-4754-8b19-f8858f06b2f7
SCIP notification number (Poland)
dd6c1fe3-048f-49b3-836f-9130aad2d944
SCIP notification number (Romania)
d6036267-4e81-4199-af97-fb65ddb3fd68
SCIP notification number (Sweden)
3f6fd8bd-3a43-4ad6-8cbd-9b0b74bb0627
Ratings per
IEC/EN 60664-1
Rated voltage (III / 3)
250V
Rated impulse voltage (III / 3)
4kV
Rated voltage (III/2)
320V
Rated surge voltage (III/2)
4kV
Nominal voltage (II/2)
630V
Rated surge voltage (II/2)
4kV
Rated current
16A
Legend (ratings)
(III / 2) ? Overvoltage category III / Pollution degree 2
Approvals per
CSA
Rated voltage UL (Use Group B)
300V
Rated current UL (Use Group B)
15A
Rated voltage UL (Use Group D)
300V
Rated current UL (Use Group D)
10A
Rated voltage (UL 1977)
600V
Rated current UL 1977
15A
Rated voltage CSA (Use Group B)
300V
Rated current CSA (Use Group B)
15A
Rated voltage CSA (Use Group D)
300V
Rated current CSA (Use Group D)
10A
Number of poles
10
Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment
DIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests
DIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation location
Service life test, Category?1, Class?A/B
Function test with noise-like vibration
Test passed according to Section 8 of the standard
Frequency
f1= 5 Hz to f2= 150 Hz
Acceleration
5g (highest test level used for all axes)
Test duration per axis
5 h
Test directions
X, Y and Z axes
Monitoring for contact faults/interruptions
Passed
Voltage drop measurement before and after each axis
Passed
Simulated service life test through increased levels of noise-like vibration
Test passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptions
Passed
Extended test scope: Voltage drop measurement before and after each axis
Passed
Shock test
Test passed according to Section 10 of the standard
Shock form
Half sine
Shock duration
30 ms
Number of shocks per axis
3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipment
Passed