Product Model

231-572/108-000

In Stock
Last updated: 2025/4/19
wago 231-572/108-000

Selling Points

  • 1High current stability up to 16 A with 1.2 x 1.2 mm solder pins.
  • 2Angled design for easy PCB mounting in tight spaces.
  • 3Threaded flange for secure locking in place.
  • 412-pole configuration with 5.08 mm pin spacing.
  • 5Certified for various standards including CSA, DEKRA, and UL.
Product Details
231-572/108-000
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Safety information
TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated.
Variants:
Other pole numbers
Total number of potentials
12
Number of connection types
1
Number of levels
1
Pin spacing
5.08?mm?/ 0.2?inches
Width
70.96?mm?/ 2.794?inches
Height
12.2?mm?/ 0.48?inches
Height from the surface
8.4?mm?/ 0.331?inches
Depth
12?mm?/ 0.472?inches
Solder pin length
3.8mm
Solder pin dimensions
1.2 x 1.2?mm
Drilled hole diameter with tolerance
1.7(+0.1)mm
Variable coding
Yes
Anti-rotation protection
Yes
Contact type (pluggable connector)
Male connector/plug
Connector (connection type)
for PCB
Mismating protection
No
Plugging without loss of pin spacing
No
Mating direction to the PCB
Locking of plug-in connection
Threaded flange
PCB contact
THT
Solder pin arrangement
over the entire male connector (in-line)
Number of solder pins per potential
1
Note (material data)
Information on material specifications can be found here
Color
orange
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Contact material
Electrolytic copper (ECu)
Contact plating
Tin
Fire load
0.079MJ
Weight
5.3g
Limit temperature range
-60 … +100?°C
Processing temperature
-35 … +60?°C
Product Group
3 (Multi Conn. System)
eCl@ss 10.0
27-44-04-02
eCl@ss 9.0
27-44-04-02
ETIM 9.0
EC002637
ETIM 8.0
EC002637
ECCN
NO US CLASSIFICATION
PU (SPU)
100?pcs
Packaging type
box
Country of origin
PL
GTIN
4045454845476
Customs tariff number
8536694040
CAS-No.
7439-92-1
REACH Candidate List Substance
Lead
RoHS Compliance Status
Compliant,With Exemption
RoHS Exemption
6(c)
SCIP notification number (Austria)
0c01dd9f-80d4-451a-8140-23fc2d0d4ab0
SCIP notification number (Belgium)
861efb92-7fb4-48d9-ae3f-d6fe3312d6af
SCIP notification number (Bulgaria)
aa3f2de1-d938-4a54-967e-78eeae1a2719
SCIP notification number (Czech Republic)
a098c7e7-2a6f-4f14-8900-68f24205f693
SCIP notification number (Denmark)
f541744f-bd6d-4ba5-9846-09e894e41e30
SCIP notification number (Finland)
c349755f-1da7-478f-94b3-fdb07e54a752
SCIP notification number (France)
83be9329-60b8-4f7f-9201-17d92bdeaa46
SCIP notification number (Germany)
c7674632-198d-412e-bcb3-310ea8319b55
SCIP notification number (Hungary)
0fd7b640-f627-4bc8-b693-6692ba1f3e1b
SCIP notification number (Italy)
b79f8b49-4c76-4440-935f-48b5d6c7f9b5
SCIP notification number (Netherlands)
515091e1-f95b-4a0a-945f-999a55cc6f51
SCIP notification number (Poland)
d682f8f6-7d3d-4f73-a305-e76c2ebb5e9b
SCIP notification number (Romania)
1823d54d-2cd2-4d26-b457-1227fa89d199
SCIP notification number (Sweden)
9e222fd2-b49f-4ffc-81da-7c3c1e0acb49
Ratings per
IEC/EN 60664-1
Rated voltage (III / 3)
250V
Rated impulse voltage (III / 3)
4kV
Rated voltage (III/2)
320V
Rated surge voltage (III/2)
4kV
Nominal voltage (II/2)
630V
Rated surge voltage (II/2)
4kV
Rated current
16A
Legend (ratings)
(III / 2) ? Overvoltage category III / Pollution degree 2
Approvals per
CSA
Rated voltage UL (Use Group B)
300V
Rated current UL (Use Group B)
15A
Rated voltage UL (Use Group D)
300V
Rated current UL (Use Group D)
10A
Rated voltage (UL 1977)
600V
Rated current UL 1977
15A
Rated voltage CSA (Use Group B)
300V
Rated current CSA (Use Group B)
15A
Rated voltage CSA (Use Group D)
300V
Rated current CSA (Use Group D)
10A
Number of poles
12
Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment
DIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests
DIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation location
Service life test, Category?1, Class?A/B
Function test with noise-like vibration
Test passed according to Section 8 of the standard
Frequency
f1= 5 Hz to f2= 150 Hz
Acceleration
5g (highest test level used for all axes)
Test duration per axis
5 h
Test directions
X, Y and Z axes
Monitoring for contact faults/interruptions
Passed
Voltage drop measurement before and after each axis
Passed
Simulated service life test through increased levels of noise-like vibration
Test passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptions
Passed
Extended test scope: Voltage drop measurement before and after each axis
Passed
Shock test
Test passed according to Section 10 of the standard
Shock form
Half sine
Shock duration
30 ms
Number of shocks per axis
3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipment
Passed

Specifications may be subject to change without notice