Product Model
231-574/108-000

Selling Points
- 1High-Quality Construction: Made from durable electrolytic copper with tin plating for reliable connections.
- 2Versatile Mounting Options: Suitable for both horizontal and vertical PCB mounting via straight or angled solder pins.
- 3Efficient Current Handling: Supports nominal current up to 16 A, enhancing stability in demanding applications.
- 4Comprehensive Certifications: Meets DEKRA, CSA, UL, and IEC standards for safety and performance.
- 5Easy Integration: Compatible with a range of systems and easy to integrate into existing setups.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Safety information | TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated. | Variants: | Other pole numbers |
Total number of potentials | 14 | Number of connection types | 1 |
Number of levels | 1 | Pin spacing | 5.08?mm?/ 0.2?inches |
Width | 81.12?mm?/ 3.194?inches | Height | 12.2?mm?/ 0.48?inches |
Height from the surface | 8.4?mm?/ 0.331?inches | Depth | 12?mm?/ 0.472?inches |
Solder pin length | 3.8mm | Solder pin dimensions | 1.2 x 1.2?mm |
Drilled hole diameter with tolerance | 1.7(+0.1)mm | Variable coding | Yes |
Anti-rotation protection | Yes | Contact type (pluggable connector) | Male connector/plug |
Connector (connection type) | for PCB | Mismating protection | No |
Plugging without loss of pin spacing | No | Mating direction to the PCB | 0° |
Locking of plug-in connection | Threaded flange | PCB contact | THT |
Solder pin arrangement | over the entire male connector (in-line) | Number of solder pins per potential | 1 |
Note (material data) | Information on material specifications can be found here | Color | orange |
Material group | I | Insulation material (main housing) | Polyamide (PA66) |
Flammability class per UL94 | V0 | Contact material | Electrolytic copper (ECu) |
Contact plating | Tin | Fire load | 0.09MJ |
Weight | 6g | Limit temperature range | -60 … +100?°C |
Processing temperature | -35 … +60?°C | Product Group | 3 (Multi Conn. System) |
eCl@ss 10.0 | 27-44-04-02 | eCl@ss 9.0 | 27-44-04-02 |
ETIM 9.0 | EC002637 | ETIM 8.0 | EC002637 |
ECCN | NO US CLASSIFICATION | PU (SPU) | 50?pcs |
Packaging type | box | Country of origin | PL |
GTIN | 4045454845490 | Customs tariff number | 8536694040 |
CAS-No. | 7439-92-1 | REACH Candidate List Substance | Lead |
RoHS Compliance Status | Compliant,With Exemption | RoHS Exemption | 6(c) |
SCIP notification number (Austria) | 01726a8e-9a08-42eb-bc74-a5d6a569faa8 | SCIP notification number (Belgium) | cc2da168-609a-4bd5-aa64-cbe642b02684 |
SCIP notification number (Bulgaria) | 1be74c19-f8bc-4536-aa33-21fa5b5a643b | SCIP notification number (Czech Republic) | 19b44f47-ba55-49d3-aabd-f1f4ac49b057 |
SCIP notification number (Denmark) | 9d309b43-1b31-419d-b4a8-ea802441f221 | SCIP notification number (Finland) | 5537c219-5de4-4c5a-b441-a16f5bb81476 |
SCIP notification number (France) | f54fc45a-65e3-4adc-9461-b98cc10e620d | SCIP notification number (Germany) | 2258ec97-5fc7-4bf3-8138-2a6fe5ef099e |
SCIP notification number (Hungary) | e1578491-d749-4725-8960-62721b270daa | SCIP notification number (Italy) | dbbe02e3-719d-46ee-9dd4-3bdc1de9aa8a |
SCIP notification number (Netherlands) | 8bd4630b-c0ea-45fe-a09d-50548a3c7619 | SCIP notification number (Poland) | baa71555-ac15-46a8-8524-3830d5c428e2 |
SCIP notification number (Romania) | a154387d-30a0-4e1d-a2a7-d4c754885e6c | SCIP notification number (Sweden) | 4d52fd32-1086-4d0c-bd82-525344b2201f |
Ratings per | IEC/EN 60664-1 | Rated voltage (III / 3) | 250V |
Rated impulse voltage (III / 3) | 4kV | Rated voltage (III/2) | 320V |
Rated surge voltage (III/2) | 4kV | Nominal voltage (II/2) | 630V |
Rated surge voltage (II/2) | 4kV | Rated current | 16A |
Legend (ratings) | (III / 2) ? Overvoltage category III / Pollution degree 2 | Approvals per | CSA |
Rated voltage UL (Use Group B) | 300V | Rated current UL (Use Group B) | 15A |
Rated voltage UL (Use Group D) | 300V | Rated current UL (Use Group D) | 10A |
Rated voltage (UL 1977) | 600V | Rated current UL 1977 | 15A |
Rated voltage CSA (Use Group B) | 300V | Rated current CSA (Use Group B) | 15A |
Rated voltage CSA (Use Group D) | 300V | Rated current CSA (Use Group D) | 10A |
Number of poles | 14 | Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment | DIN EN 50155 (VDE 0115-200):2022-06 |
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests | DIN EN 61373 (VDE 0115-0106):2011-04 | Spectrum/Installation location | Service life test, Category?1, Class?A/B |
Function test with noise-like vibration | Test passed according to Section 8 of the standard | Frequency | f1= 5 Hz to f2= 150 Hz |
Acceleration | 5g (highest test level used for all axes) | Test duration per axis | 5 h |
Test directions | X, Y and Z axes | Monitoring for contact faults/interruptions | Passed |
Voltage drop measurement before and after each axis | Passed | Simulated service life test through increased levels of noise-like vibration | Test passed according to Section 9 of the standard |
Extended test scope: Monitoring for contact faults/interruptions | Passed | Extended test scope: Voltage drop measurement before and after each axis | Passed |
Shock test | Test passed according to Section 10 of the standard | Shock form | Half sine |
Shock duration | 30 ms | Number of shocks per axis | 3 pos. und 3 neg. |
Vibration and shock stress for rolling stock equipment | Passed |
Specifications may be subject to change without notice