Product Model
231-640/109-000

Selling Points
- 110-Pole Connection: Ideal for complex wiring applications.
- 25.08 mm Pin Spacing: Ensures precise and reliable connections.
- 3Threaded Flange: Provides secure and stable mounting.
- 4Anti-Rotation Protection: Prevents accidental disconnection.
- 5CSA and UL 1059 Approvals: Meets high standards for safety and performance.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Safety information | TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated. | Variants: | Other pole numbers |
Clamping units | 10 | Total number of potentials | 10 |
Number of connection types | 1 | Number of levels | 1 |
Pin spacing | 5.08?mm?/ 0.2?inches | Width | 60.7?mm?/ 2.39?inches |
Height | 14.3?mm?/ 0.563?inches | Depth | 27.5?mm?/ 1.083?inches |
Variable coding | Yes | Anti-rotation protection | Yes |
Contact type (pluggable connector) | Male connector/plug | Connector (connection type) | for conductor |
Mismating protection | No | Plugging without loss of pin spacing | No |
Locking of plug-in connection | Threaded flange | Note (material data) | Information on material specifications can be found here |
Color | orange | Material group | I |
Insulation material (main housing) | Polyamide (PA66) | Flammability class per UL94 | V0 |
Clamping spring material | Chrome-nickel spring steel (CrNi) | Contact material | Electrolytic copper (ECu) |
Contact plating | Tin | Fire load | 0.266MJ |
Weight | 16.1g | Limit temperature range | -60 … +100?°C |
Processing temperature | -35 … +60?°C | Product Group | 3 (Multi Conn. System) |
eCl@ss 10.0 | 27-44-03-09 | eCl@ss 9.0 | 27-44-03-09 |
ETIM 9.0 | EC002638 | ETIM 8.0 | EC002638 |
ECCN | NO US CLASSIFICATION | PU (SPU) | 25?pcs |
Packaging type | box | Country of origin | DE |
GTIN | 4045454417123 | Customs tariff number | 8536694040 |
CAS-No. | 7439-92-1 | REACH Candidate List Substance | Lead |
RoHS Compliance Status | Compliant,With Exemption | RoHS Exemption | 6(c) |
SCIP notification number (Austria) | 09010db8-8813-4476-90e6-a2e256e991eb | SCIP notification number (Belgium) | a4ec92e6-a8e5-4352-ba8b-74f665a146ae |
SCIP notification number (Bulgaria) | 3b8d7f7e-384b-4450-9e5d-f3549eef8c34 | SCIP notification number (Czech Republic) | 459d0aa2-2360-4e96-b82c-b6c7acf875f6 |
SCIP notification number (Denmark) | db79881a-802a-4ebb-b9a4-6c00d808a2ce | SCIP notification number (Finland) | 238de3b9-1523-4b91-8fc2-dc2e39be1ccb |
SCIP notification number (France) | 935393c9-6662-4e2d-961e-f2e05a7dfd85 | SCIP notification number (Germany) | 2a2f974a-2899-48b1-9dc5-86e7922b4110 |
SCIP notification number (Hungary) | dc8f8bda-a13a-4f17-b330-4a53e032c517 | SCIP notification number (Italy) | 37b9c9ba-449a-4f58-839b-78358d98cb3e |
SCIP notification number (Netherlands) | fbfba25a-58d5-4844-b7c3-3efff0655516 | SCIP notification number (Poland) | 6c49fee1-3d48-430d-83e3-88bbeb086cda |
SCIP notification number (Romania) | 8b35b00e-88e2-4201-9ff2-3d680a3624ca | SCIP notification number (Sweden) | 84f7892a-8fed-47bb-8c59-2a48074ceec7 |
Ratings per | IEC/EN 60664-1 | Rated voltage (III / 3) | 320V |
Rated impulse voltage (III / 3) | 4kV | Rated voltage (III/2) | 320V |
Rated surge voltage (III/2) | 4kV | Nominal voltage (II/2) | 630V |
Rated surge voltage (II/2) | 4kV | Rated current | 12A |
Legend (ratings) | (III / 2) ? Overvoltage category III / Pollution degree 2 | Approvals per | CSA |
Rated voltage UL (Use Group B) | 300V | Rated current UL (Use Group B) | 15A |
Rated voltage UL (Use Group D) | 300V | Rated current UL (Use Group D) | 10A |
Rated voltage (UL 1977) | 600V | Rated current UL 1977 | 15A |
Rated voltage CSA (Use Group B) | 300V | Rated current CSA (Use Group B) | 15A |
Rated voltage CSA (Use Group D) | 300V | Rated current CSA (Use Group D) | 10A |
Connection technology | CAGE CLAMP? | Actuation type | Operating tool |
Actuation direction 1 | Operation parallel to conductor entry | Actuation direction 2 | Operation perpendicular to conductor entry |
Solid conductor | 0.08 … 2.5?mm2?/ 28 … 12?AWG | Fine-stranded conductor | 0.08 … 2.5?mm2?/ 28 … 12?AWG |
Fine-stranded conductor; with insulated ferrule | 0.25 … 1.5?mm2 | Fine-stranded conductor; with uninsulated ferrule | 0.25 … 2.5?mm2 |
Strip length | 8 … 9?mm?/ 0.31 … 0.35?inches | Number of poles | 10 |
Conductor entry direction to mating direction | 0° | Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment | DIN EN 50155 (VDE 0115-200):2022-06 |
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests | DIN EN 61373 (VDE 0115-0106):2011-04 | Spectrum/Installation location | Service life test, Category?1, Class?A/B |
Function test with noise-like vibration | Test passed according to Section 8 of the standard | Frequency | f1= 5 Hz to f2= 150 Hz |
Acceleration | 5g (highest test level used for all axes) | Test duration per axis | 5 h |
Test directions | X, Y and Z axes | Monitoring for contact faults/interruptions | Passed |
Voltage drop measurement before and after each axis | Passed | Simulated service life test through increased levels of noise-like vibration | Test passed according to Section 9 of the standard |
Extended test scope: Monitoring for contact faults/interruptions | Passed | Extended test scope: Voltage drop measurement before and after each axis | Passed |
Shock test | Test passed according to Section 10 of the standard | Shock form | Half sine |
Shock duration | 30 ms | Number of shocks per axis | 3 pos. und 3 neg. |
Vibration and shock stress for rolling stock equipment | Passed |
Specifications may be subject to change without notice