Product Model
231-642/109-000

Selling Points
- 112-Pole Design: Ideal for complex PCB applications with multiple connections.
- 25.08 mm Pin Spacing: Ensures precise and consistent wiring.
- 3Threaded Flange: Provides a secure and robust mounting solution.
- 4Orange Color: Easy identification in industrial settings.
- 5Rugged Construction: Durable and reliable for demanding environments.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Safety information | TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated. | Variants: | Other pole numbers |
Clamping units | 12 | Total number of potentials | 12 |
Number of connection types | 1 | Number of levels | 1 |
Pin spacing | 5.08?mm?/ 0.2?inches | Width | 70.86?mm?/ 2.79?inches |
Height | 14.3?mm?/ 0.563?inches | Depth | 27.5?mm?/ 1.083?inches |
Variable coding | Yes | Anti-rotation protection | Yes |
Contact type (pluggable connector) | Male connector/plug | Connector (connection type) | for conductor |
Mismating protection | No | Plugging without loss of pin spacing | No |
Locking of plug-in connection | Threaded flange | Note (material data) | Information on material specifications can be found here |
Color | orange | Material group | I |
Insulation material (main housing) | Polyamide (PA66) | Flammability class per UL94 | V0 |
Clamping spring material | Chrome-nickel spring steel (CrNi) | Contact material | Electrolytic copper (ECu) |
Contact plating | Tin | Fire load | 0.315MJ |
Weight | 19g | Limit temperature range | -60 … +100?°C |
Processing temperature | -35 … +60?°C | Product Group | 3 (Multi Conn. System) |
eCl@ss 10.0 | 27-44-03-09 | eCl@ss 9.0 | 27-44-03-09 |
ETIM 9.0 | EC002638 | ETIM 8.0 | EC002638 |
ECCN | NO US CLASSIFICATION | PU (SPU) | 25?pcs |
Packaging type | box | Country of origin | DE |
GTIN | 4045454029241 | Customs tariff number | 8536694040 |
CAS-No. | 7439-92-1 | REACH Candidate List Substance | Lead |
RoHS Compliance Status | Compliant,With Exemption | RoHS Exemption | 6(c) |
SCIP notification number (Austria) | 0bf7c89b-b195-4fcb-911c-9edc227707bc | SCIP notification number (Belgium) | 2b3caa05-524d-4568-b312-8c38c5e898c7 |
SCIP notification number (Bulgaria) | d1942e0a-2474-4a6e-84a7-d3127d85b2bd | SCIP notification number (Czech Republic) | 9ec89500-88dc-4c82-afdf-0ec765c58696 |
SCIP notification number (Denmark) | 643d375c-66fc-4da7-a010-1b90c5814982 | SCIP notification number (Finland) | 3ddc5a55-cbd0-40c2-a660-e0643a99f2b9 |
SCIP notification number (France) | f64fe4ef-4c76-4b80-a6f4-8640cef0fc44 | SCIP notification number (Germany) | cc520526-74a1-4642-be8e-c02d1b9363e5 |
SCIP notification number (Hungary) | aabed05b-138c-4595-9ef4-48ed3bc09007 | SCIP notification number (Italy) | 58088bd9-70dc-40f1-a3e7-d8c2d85f71b4 |
SCIP notification number (Netherlands) | e10b7bba-d6cf-4cd3-8d8f-b2942e0404b9 | SCIP notification number (Poland) | d1908bc5-c333-4b78-99e7-176de478dd9d |
SCIP notification number (Romania) | 6461fcbe-a029-4193-888f-2d2ab2c5e5f4 | SCIP notification number (Sweden) | 223a9e56-00b6-4fa6-8d6a-d21a5f088c5a |
Ratings per | IEC/EN 60664-1 | Rated voltage (III / 3) | 320V |
Rated impulse voltage (III / 3) | 4kV | Rated voltage (III/2) | 320V |
Rated surge voltage (III/2) | 4kV | Nominal voltage (II/2) | 630V |
Rated surge voltage (II/2) | 4kV | Rated current | 12A |
Legend (ratings) | (III / 2) ? Overvoltage category III / Pollution degree 2 | Approvals per | CSA |
Rated voltage UL (Use Group B) | 300V | Rated current UL (Use Group B) | 15A |
Rated voltage UL (Use Group D) | 300V | Rated current UL (Use Group D) | 10A |
Rated voltage (UL 1977) | 600V | Rated current UL 1977 | 15A |
Rated voltage CSA (Use Group B) | 300V | Rated current CSA (Use Group B) | 15A |
Rated voltage CSA (Use Group D) | 300V | Rated current CSA (Use Group D) | 10A |
Connection technology | CAGE CLAMP? | Actuation type | Operating tool |
Actuation direction 1 | Operation parallel to conductor entry | Actuation direction 2 | Operation perpendicular to conductor entry |
Solid conductor | 0.08 … 2.5?mm2?/ 28 … 12?AWG | Fine-stranded conductor | 0.08 … 2.5?mm2?/ 28 … 12?AWG |
Fine-stranded conductor; with insulated ferrule | 0.25 … 1.5?mm2 | Fine-stranded conductor; with uninsulated ferrule | 0.25 … 2.5?mm2 |
Strip length | 8 … 9?mm?/ 0.31 … 0.35?inches | Number of poles | 12 |
Conductor entry direction to mating direction | 0° | Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment | DIN EN 50155 (VDE 0115-200):2022-06 |
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests | DIN EN 61373 (VDE 0115-0106):2011-04 | Spectrum/Installation location | Service life test, Category?1, Class?A/B |
Function test with noise-like vibration | Test passed according to Section 8 of the standard | Frequency | f1= 5 Hz to f2= 150 Hz |
Acceleration | 5g (highest test level used for all axes) | Test duration per axis | 5 h |
Test directions | X, Y and Z axes | Monitoring for contact faults/interruptions | Passed |
Voltage drop measurement before and after each axis | Passed | Simulated service life test through increased levels of noise-like vibration | Test passed according to Section 9 of the standard |
Extended test scope: Monitoring for contact faults/interruptions | Passed | Extended test scope: Voltage drop measurement before and after each axis | Passed |
Shock test | Test passed according to Section 10 of the standard | Shock form | Half sine |
Shock duration | 30 ms | Number of shocks per axis | 3 pos. und 3 neg. |
Vibration and shock stress for rolling stock equipment | Passed |
Specifications may be subject to change without notice