Product Model

231-642/109-000

In Stock
Last updated: 2025/4/18
wago 231-642/109-000

Selling Points

  • 112-Pole Design: Ideal for complex PCB applications with multiple connections.
  • 25.08 mm Pin Spacing: Ensures precise and consistent wiring.
  • 3Threaded Flange: Provides a secure and robust mounting solution.
  • 4Orange Color: Easy identification in industrial settings.
  • 5Rugged Construction: Durable and reliable for demanding environments.
Product Details
231-642/109-000
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Safety information
TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated.
Variants:
Other pole numbers
Clamping units
12
Total number of potentials
12
Number of connection types
1
Number of levels
1
Pin spacing
5.08?mm?/ 0.2?inches
Width
70.86?mm?/ 2.79?inches
Height
14.3?mm?/ 0.563?inches
Depth
27.5?mm?/ 1.083?inches
Variable coding
Yes
Anti-rotation protection
Yes
Contact type (pluggable connector)
Male connector/plug
Connector (connection type)
for conductor
Mismating protection
No
Plugging without loss of pin spacing
No
Locking of plug-in connection
Threaded flange
Note (material data)
Information on material specifications can be found here
Color
orange
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Clamping spring material
Chrome-nickel spring steel (CrNi)
Contact material
Electrolytic copper (ECu)
Contact plating
Tin
Fire load
0.315MJ
Weight
19g
Limit temperature range
-60 … +100?°C
Processing temperature
-35 … +60?°C
Product Group
3 (Multi Conn. System)
eCl@ss 10.0
27-44-03-09
eCl@ss 9.0
27-44-03-09
ETIM 9.0
EC002638
ETIM 8.0
EC002638
ECCN
NO US CLASSIFICATION
PU (SPU)
25?pcs
Packaging type
box
Country of origin
DE
GTIN
4045454029241
Customs tariff number
8536694040
CAS-No.
7439-92-1
REACH Candidate List Substance
Lead
RoHS Compliance Status
Compliant,With Exemption
RoHS Exemption
6(c)
SCIP notification number (Austria)
0bf7c89b-b195-4fcb-911c-9edc227707bc
SCIP notification number (Belgium)
2b3caa05-524d-4568-b312-8c38c5e898c7
SCIP notification number (Bulgaria)
d1942e0a-2474-4a6e-84a7-d3127d85b2bd
SCIP notification number (Czech Republic)
9ec89500-88dc-4c82-afdf-0ec765c58696
SCIP notification number (Denmark)
643d375c-66fc-4da7-a010-1b90c5814982
SCIP notification number (Finland)
3ddc5a55-cbd0-40c2-a660-e0643a99f2b9
SCIP notification number (France)
f64fe4ef-4c76-4b80-a6f4-8640cef0fc44
SCIP notification number (Germany)
cc520526-74a1-4642-be8e-c02d1b9363e5
SCIP notification number (Hungary)
aabed05b-138c-4595-9ef4-48ed3bc09007
SCIP notification number (Italy)
58088bd9-70dc-40f1-a3e7-d8c2d85f71b4
SCIP notification number (Netherlands)
e10b7bba-d6cf-4cd3-8d8f-b2942e0404b9
SCIP notification number (Poland)
d1908bc5-c333-4b78-99e7-176de478dd9d
SCIP notification number (Romania)
6461fcbe-a029-4193-888f-2d2ab2c5e5f4
SCIP notification number (Sweden)
223a9e56-00b6-4fa6-8d6a-d21a5f088c5a
Ratings per
IEC/EN 60664-1
Rated voltage (III / 3)
320V
Rated impulse voltage (III / 3)
4kV
Rated voltage (III/2)
320V
Rated surge voltage (III/2)
4kV
Nominal voltage (II/2)
630V
Rated surge voltage (II/2)
4kV
Rated current
12A
Legend (ratings)
(III / 2) ? Overvoltage category III / Pollution degree 2
Approvals per
CSA
Rated voltage UL (Use Group B)
300V
Rated current UL (Use Group B)
15A
Rated voltage UL (Use Group D)
300V
Rated current UL (Use Group D)
10A
Rated voltage (UL 1977)
600V
Rated current UL 1977
15A
Rated voltage CSA (Use Group B)
300V
Rated current CSA (Use Group B)
15A
Rated voltage CSA (Use Group D)
300V
Rated current CSA (Use Group D)
10A
Connection technology
CAGE CLAMP?
Actuation type
Operating tool
Actuation direction 1
Operation parallel to conductor entry
Actuation direction 2
Operation perpendicular to conductor entry
Solid conductor
0.08 … 2.5?mm2?/ 28 … 12?AWG
Fine-stranded conductor
0.08 … 2.5?mm2?/ 28 … 12?AWG
Fine-stranded conductor; with insulated ferrule
0.25 … 1.5?mm2
Fine-stranded conductor; with uninsulated ferrule
0.25 … 2.5?mm2
Strip length
8 … 9?mm?/ 0.31 … 0.35?inches
Number of poles
12
Conductor entry direction to mating direction
Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment
DIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests
DIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation location
Service life test, Category?1, Class?A/B
Function test with noise-like vibration
Test passed according to Section 8 of the standard
Frequency
f1= 5 Hz to f2= 150 Hz
Acceleration
5g (highest test level used for all axes)
Test duration per axis
5 h
Test directions
X, Y and Z axes
Monitoring for contact faults/interruptions
Passed
Voltage drop measurement before and after each axis
Passed
Simulated service life test through increased levels of noise-like vibration
Test passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptions
Passed
Extended test scope: Voltage drop measurement before and after each axis
Passed
Shock test
Test passed according to Section 10 of the standard
Shock form
Half sine
Shock duration
30 ms
Number of shocks per axis
3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipment
Passed

Specifications may be subject to change without notice