Product Model

236-623

In Stock
Last updated: 2025/4/19
wago 236-623

Selling Points

  • 1Secure Connections: Ensures reliable and efficient connectivity with CAGE CLAMP technology.
  • 2Maintenance-Free: Designed for long-lasting performance without the need for frequent maintenance.
  • 3Versatile Applications: Suitable for industrial automation, building technology, and process control.
  • 4High Performance: Supports up to 24A rated current and 8kV surge voltage.
  • 5Easy Installation: Features 45° conductor entry angle for easy wiring options and metric or inch pin spacing adjustment.
Product Details
236-623
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Variants:
Other pole numbers
Clamping units
23
Total number of potentials
23
Number of connection types
1
Number of levels
1
Pin spacing
10/10.16?mm?/ 0.394/0.4?inches
Width
232.3?mm?/ 9.146?inches
Height
17?mm?/ 0.669?inches
Height from the surface
13?mm?/ 0.512?inches
Depth
14?mm?/ 0.551?inches
Solder pin length
4mm
Solder pin dimensions
0.7 x 0.7?mm
Drilled hole diameter with tolerance
1.1(+0.1)mm
PCB contact
THT
Solder pin arrangement
over the entire terminal strip (in-line)
Number of solder pins per potential
2
Note (material data)
Information on material specifications can be found here
Color
gray
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Clamping spring material
Chrome-nickel spring steel (CrNi)
Contact material
Electrolytic copper (ECu)
Contact plating
Tin
Fire load
0.556MJ
Weight
29.5g
Limit temperature range
-60 … +105?°C
Product Group
4 (Printed Circuit Connectors)
eCl@ss 10.0
27-44-04-01
eCl@ss 9.0
27-44-04-01
ETIM 9.0
EC002643
ETIM 8.0
EC002643
ECCN
NO US CLASSIFICATION
PU (SPU)
20?(5)?pcs
Packaging type
box
Country of origin
CH
GTIN
4017332304108
Customs tariff number
8536904000
RoHS Compliance Status
Compliant,No Exemption
Ratings per
IEC/EN 60664-1
Rated voltage (III / 3)
630V
Rated impulse voltage (III / 3)
8kV
Rated voltage (III/2)
1000V
Rated surge voltage (III/2)
8kV
Nominal voltage (II/2)
1000V
Rated surge voltage (II/2)
8kV
Rated current
24A
Legend (ratings)
(III / 2) ? Overvoltage category III / Pollution degree 2
Approvals per
CSA
Rated voltage UL (Use Group B)
300V
Rated current UL (Use Group B)
15A
Rated voltage UL (Use Group D)
300V
Rated current UL (Use Group D)
10A
Rated voltage CSA (Use Group B)
300V
Rated current CSA (Use Group B)
15A
Rated voltage CSA (Use Group D)
300V
Rated current CSA (Use Group D)
10A
Connection technology
CAGE CLAMP?
Actuation type
Operating tool
Solid conductor
0.08 … 2.5?mm2?/ 28 … 12?AWG
Fine-stranded conductor
0.08 … 2.5?mm2?/ 28 … 12?AWG
Fine-stranded conductor; with insulated ferrule
0.25 … 1.5?mm2
Fine-stranded conductor; with uninsulated ferrule
0.25 … 1.5?mm2
Note (conductor cross-section)
12 AWG: THHN, THWN
Strip length
5 … 6?mm?/ 0.2 … 0.24?inches
Conductor connection direction to PCB
45°
Number of poles
23

Specifications may be subject to change without notice