Product Model

250-1416

In Stock
Last updated: 2025/4/20
wago 250-1416

Selling Points

  • 1High-Quality Construction: Built with durable materials for long-lasting performance.
  • 2Easy Installation: Push-in CAGE CLAMP technology simplifies wiring.
  • 316-Pole Design: Suitable for a wide range of electrical connections.
  • 4Ratings Compliance: Meets IEC/EN 60664-1 and UL/CSA standards.
  • 5Versatile Compatibility: Compatible with various electrical systems and automation applications.
Product Details
250-1416
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Variants:
Other pole numbers
Clamping units
16
Total number of potentials
16
Number of connection types
1
Number of levels
1
Pin spacing
2.54?mm?/ 0.1?inches
Width
42.14?mm?/ 1.659?inches
Height
16.7?mm?/ 0.657?inches
Height from the surface
13.1?mm?/ 0.516?inches
Depth
12?mm?/ 0.472?inches
Solder pin length
3.6mm
Solder pin dimensions
0.4 x 0.75?mm
Drilled hole diameter with tolerance
1.1(+0.1)mm
PCB contact
THT
Solder pin arrangement
over the entire terminal strip (staggered)
Number of solder pins per potential
1
Note (material data)
Information on material specifications can be found here
Color
gray
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Clamping spring material
Copper alloy
Contact plating
Tin
Fire load
0.118MJ
Weight
5.8g
Limit temperature range
-60 … +105?°C
Product Group
4 (Printed Circuit Connectors)
eCl@ss 10.0
27-44-04-01
eCl@ss 9.0
27-44-04-01
ETIM 9.0
EC002643
ETIM 8.0
EC002643
ECCN
NO US CLASSIFICATION
PU (SPU)
100?(25)?pcs
Packaging type
box
Country of origin
CH
GTIN
4044918643399
Customs tariff number
8536904000
RoHS Compliance Status
Compliant,No Exemption
Ratings per
IEC/EN 60664-1
Rated voltage (III / 3)
160V
Rated impulse voltage (III / 3)
2.5kV
Rated voltage (III/2)
160V
Rated surge voltage (III/2)
2.5kV
Nominal voltage (II/2)
320V
Rated surge voltage (II/2)
2.5kV
Rated current
4A
Legend (ratings)
(III / 2) ? Overvoltage category III / Pollution degree 2
Approvals per
CSA
Rated voltage UL (Use Group B)
300V
Rated current UL (Use Group B)
5A
Rated voltage UL (Use Group D)
300V
Rated current UL (Use Group D)
5A
Rated voltage CSA (Use Group B)
300V
Rated current CSA (Use Group B)
5A
Rated voltage CSA (Use Group D)
300V
Rated current CSA (Use Group D)
5A
Connection technology
Push-in CAGE CLAMP?
Actuation type
Push-button
Solid conductor
0.14 … 0.5?mm2?/ 24 … 20?AWG
Fine-stranded conductor
0.2 … 0.5?mm2?/ 24 … 20?AWG
Conductor diameter
0.4 … 0.8?mm?/ 24 … 20?AWG
Strip length
8.5 … 9.5?mm?/ 0.33 … 0.37?inches
Conductor connection direction to PCB
45°
Number of poles
16