Product Model

2601-1307

In Stock
Last updated: 2025/4/19
wago 2601-1307

Selling Points

  • 1Provides seamless integration and communication in various industrial applications.
  • 2Intuitive and tool-free operation simplifies the connection process.
  • 3Constructed with high-quality materials, including electrocopper contacts and chrome-nickel spring steel clamping springs.
  • 4Supports solid and ferruled conductors, as well as fine-stranded conductors with insulated or uninsulated ferrules.
  • 5Meets international standards with certifications from IEC, CSA, UL, and DEKRA.
Product Details
2601-1307
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Variants:
Other pole numbers
Clamping units
7
Total number of potentials
7
Number of connection types
1
Number of levels
1
Pin spacing
7.5?mm?/ 0.295?inches
Width
52.3?mm?/ 2.057?inches
Height
16.35?mm?/ 0.644?inches
Height from the surface
12.75?mm
Depth
16.58?mm?/ 0.653?inches
Solder pin length
3.6mm
Solder pin dimensions
1 x 0.5?mm
Drilled hole diameter with tolerance
1.2(+0.1)mm
PCB contact
THT
Solder pin arrangement
within the terminal block (in-line)
Number of solder pins per potential
2
Note (material data)
Information on material specifications can be found here
Color
gray
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Clamping spring material
Chrome-nickel spring steel (CrNi)
Contact material
Electrolytic copper (ECu)
Contact plating
Tin
Fire load
0.177MJ
Weight
7.8g
Limit temperature range
-60 … +105?°C
Processing temperature
-35 … +60?°C
Continuous operating temperature
-60 … +105?°C
ETIM 9.0
EC002643
ETIM 8.0
EC002643
ECCN
NO US CLASSIFICATION
PU (SPU)
40?pcs
Packaging type
Box
Country of origin
PL
GTIN
4066966242157
Customs tariff number
85369010000
RoHS Compliance Status
Compliant,No Exemption
Ratings per
IEC/EN 60664-1
Rated voltage (III / 3)
500V
Rated impulse voltage (III / 3)
6kV
Rated voltage (III/2)
1000V
Rated surge voltage (III/2)
6kV
Nominal voltage (II/2)
1000V
Rated surge voltage (II/2)
6kV
Rated current
17.5A
Legend (ratings)
(III / 2) ? Overvoltage category III / Pollution degree 2
Approvals per
CSA
Rated voltage UL (Use Group B)
300V
Rated current UL (Use Group B)
15A
Rated voltage UL (Use Group C)
150V
Rated current UL (Use Group C)
15A
Rated voltage UL (Use Group D)
300V
Rated current UL (Use Group D)
10A
Rated voltage CSA (Use Group B)
300V
Rated current CSA (Use Group B)
15A
Rated voltage CSA (Use Group C)
150V
Rated current CSA (Use Group C)
15A
Rated voltage CSA (Use Group D)
300V
Rated current CSA (Use Group D)
10A
Connection technology
Push-in CAGE CLAMP?
Actuation type
Lever
Solid conductor
0.14 … 1.5?mm2?/ 26 … 14?AWG
Solid conductor; push-in termination
0.5 … 1.5?mm2?/ 26 … 14?AWG
Fine-stranded conductor
0.2 … 1.5?mm2?/ 26 … 14?AWG
Fine-stranded conductor; with insulated ferrule
0.25 … 0.75?mm2
Fine-stranded conductor; with uninsulated ferrule
0.25 … 1.5?mm2
Note (conductor cross-section)
For conductors (26 AWG) that are not rigid enough, the clamping unit must be opened using a lever.
Strip length
8 … 9?mm?/ 0.31 … 0.35?inches
Conductor connection direction to PCB
Number of poles
7

Specifications may be subject to change without notice