Product Model

2604-1504

In Stock
Last updated: 2025/4/19
wago 2604-1504

Selling Points

  • 1High current capacity up to 32A for reliable power transmission.
  • 2Easy push-in wiring with Push-in CAGE CLAMP technology.
  • 3Tool-free, intuitive lever operation for simplified connection.
  • 4Rated for 1000V and suitable for various conductor types.
  • 5Compact design with 11.5 mm pin spacing for efficient PCB mounting.
Product Details
2604-1504
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Variants:
Other pole numbers
Clamping units
4
Total number of potentials
4
Number of connection types
1
Number of levels
1
Pin spacing
11.5?mm?/ 0.453?inches
Width
41.9?mm?/ 1.65?inches
Height
20.7?mm?/ 0.815?inches
Height from the surface
16.7?mm?/ 0.657?inches
Depth
19.2?mm?/ 0.756?inches
Solder pin length
4mm
Solder pin dimensions
0.8 x 1?mm
Drilled hole diameter with tolerance
1.3(+0.1)mm
PCB contact
THT
Solder pin arrangement
over the entire terminal strip (in-line)
Number of solder pins per potential
2
Note (material data)
Information on material specifications can be found here
Color
gray
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Clamping spring material
Chrome-nickel spring steel (CrNi)
Contact material
Electrolytic copper (ECu)
Contact plating
Tin
Fire load
0.096MJ
Actuator color
orange
Weight
9.4g
Limit temperature range
-60 … +105?°C
Processing temperature
-35 … +60?°C
Continuous operating temperature
-60 … +105?°C
eCl@ss 10.0
27-44-04-01
eCl@ss 9.0
27-44-04-01
ETIM 9.0
EC002643
ETIM 8.0
EC002643
ECCN
NO US CLASSIFICATION
PU (SPU)
50?pcs
Packaging type
box
Country of origin
PL
GTIN
4055143564601
Customs tariff number
8536904000
RoHS Compliance Status
Compliant,No Exemption
Ratings per
IEC/EN 60664-1
Rated voltage (III / 3)
1000V
Rated impulse voltage (III / 3)
8kV
Rated voltage (III/2)
1000V
Rated surge voltage (III/2)
8kV
Nominal voltage (II/2)
1000V
Rated surge voltage (II/2)
8kV
Rated current
32A
Legend (ratings)
(III / 2) ? Overvoltage category III / Pollution degree 2
Approvals per
CSA
Rated voltage UL (Use Group B)
600V
Rated current UL (Use Group B)
20A
Rated voltage UL (Use Group C)
600V
Rated current UL (Use Group C)
20A
Rated voltage CSA (Use Group B)
600V
Rated current CSA (Use Group B)
20A
Rated voltage CSA (Use Group C)
600V
Rated current CSA (Use Group C)
20A
Connection technology
Push-in CAGE CLAMP?
Actuation type
Lever
Solid conductor
0.2 … 4?mm2?/ 24 … 12?AWG
Fine-stranded conductor
0.2 … 4?mm2?/ 24 … 12?AWG
Fine-stranded conductor; with insulated ferrule
0.25 … 2.5?mm2
Fine-stranded conductor; with uninsulated ferrule
0.25 … 2.5?mm2
Fine-stranded conductor; with twin ferrule
0.25 … 1.5?mm2
Strip length
9 … 11?mm?/ 0.35 … 0.43?inches
Conductor connection direction to PCB
Number of poles
4

Specifications may be subject to change without notice