Product Model
2606-3102/000-004

Selling Points
- 1Efficient Connectivity: Push-in CAGE CLAMP technology ensures quick and secure connections.
- 2High Durability: Constructed with high-quality materials for long-lasting performance.
- 3Easy Installation: Tool-free operation with an intuitive lever-actuated design.
- 4Versatile Compatibility: Compatible with AWG 24-8 conductors and suitable for various electrical and automation systems.
- 5Robust Specifications: Rated for 41A current and 800V to 1000V voltage, with an operating temperature range of -60°C to +105°C.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Variants: | Other pole numbers | Clamping units | 2 |
Total number of potentials | 2 | Number of connection types | 1 |
Number of levels | 1 | Pin spacing | 7.5 mm / 0.295 inches |
Width | 17.85 mm / 0.703 inches | Height | 31 mm / 1.22 inches |
Height from the surface | 27 mm / 1.063 inches | Depth | 24 mm / 0.945 inches |
Solder pin length | 4mm | Solder pin dimensions | 1.5 x 1.2 mm |
Drilled hole diameter with tolerance | 2(+0.1)mm | PCB contact | THT |
Solder pin arrangement | over the entire terminal strip (staggered) | Number of solder pins per potential | 1 |
Note (material data) | Information on material specifications can be found here | Color | black |
Insulation material (main housing) | Polyamide (PA66) | Flammability class per UL94 | V0 |
Clamping spring material | Chrome-nickel spring steel (CrNi) | Contact material | Electrolytic copper (ECu) |
Contact plating | Tin | Fire load | 0.2MJ |
Actuator color | orange | Weight | 9.4g |
Limit temperature range | -60 … +105 °C | Processing temperature | -35 … +60 °C |
Continuous operating temperature | -60 … +105 °C | ETIM 9.0 | EC002643 |
ETIM 8.0 | EC002643 | ECCN | NO US CLASSIFICATION |
PU (SPU) | 88 pcs | Packaging type | Box |
Country of origin | PL | GTIN | 4066966477153 |
Customs tariff number | 85369010000 | RoHS Compliance Status | Compliant,No Exemption |
Ratings per | IEC/EN 60664-1 | Rated voltage (III / 3) | 800V |
Rated impulse voltage (III / 3) | 8kV | Rated voltage (III/2) | 1000V |
Rated surge voltage (III/2) | 8kV | Nominal voltage (II/2) | 1000V |
Rated surge voltage (II/2) | 8kV | Rated current | 41A |
Legend (ratings) | (III / 2) ? Overvoltage category III / Pollution degree 2 | Approvals per | CSA |
Rated voltage UL (Use Group B) | 600V | Rated current UL (Use Group B) | 31A |
Rated voltage UL (Use Group C) | 600V | Rated current UL (Use Group C) | 31A |
Rated voltage CSA (Use Group B) | 600V | Rated current CSA (Use Group B) | 31A |
Rated voltage CSA (Use Group C) | 600V | Rated current CSA (Use Group C) | 31A |
Connection technology | Push-in CAGE CLAMP? | Actuation type | Lever |
Solid conductor | 0.2 … 10 mm2 / 24 … 8 AWG | Fine-stranded conductor | 0.2 … 10 mm2 / 24 … 8 AWG |
Fine-stranded conductor; with insulated ferrule | 0.25 … 6 mm2 | Fine-stranded conductor; with uninsulated ferrule | 0.25 … 6 mm2 |
Fine-stranded conductor; with twin ferrule | 0.25 … 2.5 mm2 | Strip length | 11 … 13 mm / 0.43 … 0.51 inches |
Conductor connection direction to PCB | 90° | Number of poles | 2 |
Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment | DIN EN 50155 (VDE 0115-200):2022-06 | Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests | DIN EN 61373 (VDE 0115-0106):2011-04 |
Spectrum/Installation location | Service life test, Category?1, Class?A/B | Function test with noise-like vibration | Test passed according to Section 8 of the standard |
Frequency | f1= 5 Hz to f2= 150 Hz | Acceleration | 5g (highest test level used for all axes) |
Test duration per axis | 5 h | Test directions | X, Y and Z axes |
Monitoring for contact faults/interruptions | Passed | Voltage drop measurement before and after each axis | Passed |
Simulated service life test through increased levels of noise-like vibration | Test passed according to Section 9 of the standard | Extended test scope: Monitoring for contact faults/interruptions | Passed |
Extended test scope: Voltage drop measurement before and after each axis | Passed | Shock test | Test passed according to Section 10 of the standard |
Shock form | Half sine | Shock duration | 30 ms |
Number of shocks per axis | 3 pos. und 3 neg. | Vibration and shock stress for rolling stock equipment | Passed |