Selling Points

  • 1High-current connectivity: Handles up to 41A with 600V UL rating for 12.5mm pin spacing.
  • 2Tool-free operation: Fingers open/close levers for easy termination without tools.
  • 3High mechanical stability: Two solder pins per contact point ensure secure connections.
  • 4Multi-core cable management: Several clamping units can be held open simultaneously.
  • 5Compliance with industry standards: Meets CSA and UL 1059 approvals for reliable use in industrial applications.
Product Details
2706-303
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Variants:
Other pole numbers
Clamping units
3
Total number of potentials
3
Number of connection types
1
Number of levels
1
Pin spacing
12.5 mm / 0.492 inches
Width
32.5 mm / 1.28 inches
Height
30 mm / 1.181 inches
Height from the surface
25.5 mm / 1.004 inches
Depth
26 mm / 1.024 inches
Solder pin length
4.5mm
Solder pin dimensions
1 x 1.4 mm
Drilled hole diameter with tolerance
1.8(+0.1)mm
PCB contact
THT
Solder pin arrangement
over the entire terminal strip (in-line)
Number of solder pins per potential
2
Note (material data)
Information on material specifications can be found here
Color
gray
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Clamping spring material
Chrome-nickel spring steel (CrNi)
Contact material
Electrolytic copper (ECu)
Contact plating
Tin
Fire load
0.425MJ
Weight
19.4g
Limit temperature range
-60 … +105 °C
Product Group
4 (Printed Circuit Connectors)
eCl@ss 10.0
27-44-04-01
eCl@ss 9.0
27-44-04-01
ETIM 9.0
EC002643
ETIM 8.0
EC002643
ECCN
NO US CLASSIFICATION
PU (SPU)
40 pcs
Packaging type
Box
Country of origin
PL
GTIN
4050821093459
Customs tariff number
8536904000
RoHS Compliance Status
Compliant,No Exemption
Ratings per
IEC/EN 60664-1
Rated voltage (III / 3)
1000V
Rated impulse voltage (III / 3)
8kV
Rated voltage (III/2)
1000V
Rated surge voltage (III/2)
8kV
Nominal voltage (II/2)
1000V
Rated surge voltage (II/2)
8kV
Rated current
41A
Legend (ratings)
(III / 2) ? Overvoltage category III / Pollution degree 2
Approvals per
UL 1059
Rated voltage UL (Use Group B)
300V
Rated current UL (Use Group B)
30A
Rated voltage UL (Use Group C)
600V
Rated current UL (Use Group C)
30A
Connection technology
CAGE CLAMP?
Actuation type
Lever
Solid conductor
0.5 … 6 mm2 / 20 … 10 AWG
Fine-stranded conductor
0.5 … 6 mm2 / 20 … 10 AWG
Fine-stranded conductor; with insulated ferrule
0.5 … 6 mm2
Fine-stranded conductor; with uninsulated ferrule
0.5 … 6 mm2
Strip length
11 … 12 mm / 0.43 … 0.47 inches
Conductor connection direction to PCB
30°
Number of poles
3

Specifications may be subject to change without notice