Product Model
280-944/281-591

Selling Points
- 1Built-in 1.5KE82C TVS Diode for Overvoltage Protection
- 2Double-Deck Design with Four Wire Connections
- 3CAGE CLAMP Spring Connections for Secure Wiring
- 4Rated for 60Vdc and 20A with Gray Finish
- 5DIN-Rail Mounting Compatible (35 x 15 and 35 x 7.5)
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Nominal operating voltage | DC?60?V | Maximum continuous voltage | DC?70?V |
Rated continuous current | 20A | Nominal discharge current (8/20?μs) (line) | 69?A |
Protection level (8/20?μs) | ≤?DC 146?V | Capacitance | ≤?1.35?nF |
Connections (number) | 4 | Connection technology | CAGE CLAMP? |
Solid conductor | 0.08 … 2.5?mm2?/ 28 … 14?AWG | Fine-stranded conductor | 0.08 … 2.5?mm2?/ 28 … 14?AWG |
Strip length | 8 … 9?mm?/ 0.31 … 0.35?inches | Width | 10?mm?/ 0.394?inches |
Height | 64 mm / 2.52 inches | Depth from upper-edge of DIN-rail | 39.5 mm / 1.555 inches |
Design | with end plate | Mounting type | DIN-35 rail |
Color | gray | Insulation material (main housing) | Polyamide (PA66) |
Material group | I | Flammability class per UL94 | V0 |
Fire load | 0.348MJ | Weight | 14.2g |
Processing temperature | -35 … +85?°C | Product Group | 1 (Rail Mounted Terminal Blocks) |
eCl@ss 10.0 | 27-14-11-27 | eCl@ss 9.0 | 27-14-11-27 |
ETIM 9.0 | EC000903 | ETIM 8.0 | EC000903 |
ECCN | NO US CLASSIFICATION | PU (SPU) | 50?(1)?pcs |
Packaging type | box | Country of origin | DE |
GTIN | 4050821515067 | Customs tariff number | 8536904000 |
CAS-No. | 7439-92-1 | REACH Candidate List Substance | Lead |
RoHS Compliance Status | Compliant,No Exemption | SCIP notification number (Austria) | a7aef2c8-d2e0-4641-86fb-68bab7adc210 |
SCIP notification number (Belgium) | 84060c06-0242-4b36-8018-29a75d4d26f9 | SCIP notification number (Bulgaria) | e0662d25-8fee-413c-92be-ec30c82903b8 |
SCIP notification number (Czech Republic) | 2b0a92d1-196b-4e18-844e-f443207ff02d | SCIP notification number (Denmark) | 8a50f022-9ec4-4cbd-a694-58b07e2ed2ca |
SCIP notification number (Finland) | c463581f-587d-4367-9592-ac046578a2fd | SCIP notification number (France) | 51a6d2a2-b3d7-4c22-b7c6-65d73f2534c6 |
SCIP notification number (Germany) | 56ae4c11-0a12-45ea-ba79-526232279f50 | SCIP notification number (Hungary) | c3641fcf-5dc2-43f7-b976-d08aed4c8878 |
SCIP notification number (Italy) | 539c8d57-d1b2-4fac-bd85-af9a4ac6f61b | SCIP notification number (Netherlands) | 3e451293-5591-404c-84b1-a569cd6ed425 |
SCIP notification number (Poland) | c379ccf7-484f-440a-93c0-dbf921157221 | SCIP notification number (Romania) | 49c110a5-5e6b-4ae8-b0fa-ec21681cff36 |
SCIP notification number (Sweden) | a574bfb5-4c59-42a7-8a9e-96f52fa05d16 |
Specifications may be subject to change without notice