wago 282-122

Selling Points

  • 1DIN-Rail Compatibility: Designed for DIN-rail 35 x 15 and 35 x 7.5 mounting.
  • 2CAGE CLAMP Technology: Secure and reliable connection method.
  • 3DEKRA Certification: Meets stringent safety standards.
  • 4Compact Design: 62 mm depth, 13 mm width, and 25.867 g weight.
  • 5Rated Current: Supports up to 10 A with a rated voltage of 500 V.
Product Details
282-122
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Clamping units
2
Total number of potentials
2
Number of levels
1
Width
13?mm?/ 0.512?inches
Height
62?mm?/ 2.441?inches
Depth from upper-edge of DIN-rail
54.5?mm?/ 2.146?inches
Design
horizontal type
Mounting type
DIN-35 rail
Marking level
Side marking
Note (material data)
Information on material specifications can be found here
Color
gray
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Fire load
0.536MJ
Weight
26g
Processing temperature
-35 … +85?°C
Continuous operating temperature
-60 … +105?°C
Product Group
1 (Rail Mounted Terminal Blocks)
eCl@ss 10.0
27-14-11-16
eCl@ss 9.0
27-14-11-16
ETIM 9.0
EC000899
ETIM 8.0
EC000899
ECCN
NO US CLASSIFICATION
PU (SPU)
40?pcs
Packaging type
box
Country of origin
CN
GTIN
4044918562027
Customs tariff number
8536904000
RoHS Compliance Status
Compliant,No Exemption
Rated voltage (III / 3)
500V
Rated impulse voltage (III / 3)
6kV
Rated current
10A
Legend (ratings)
(III / 3) ? Overvoltage category III / Pollution degree 3
Power loss (max.) P<sub>l (max.)</sub> (note)
When selecting glass cartridge fuses, make sure that the maximum power loss listed below is not exceeded. The power loss is determined according to IEC or EN?60947-7-3/VDE 0611-6 at 23°C. The temperature rise of the terminal block must be checked according to their application and mounting. Higher ambient temperatures represent an additional impact on miniature fuses. Therefore, in such applications, the rated current must be reduced if necessary. More details are available from the manufacturers.
Power loss P<sub>l</sub> max. overload and short-circuit protection (individual arrangement)
2.5W
Power loss P<sub>l</sub> max. overload and short-circuit protection (group arrangement)
2.5W
Power loss P<sub>l</sub> max. short-circuit protection (individual arrangement)
4W
Power loss P<sub>l</sub> max. short-circuit protection (group arrangement)
4W
Fuse receptacle
screwed
Fuse type
Cylindrical fuse; 5 x 20 mm
Connection technology
CAGE CLAMP?
Actuation type
Operating tool
Connectable conductor materials
Copper
Solid conductor
0.2 … 6?mm2?/ 24 … 10?AWG
Fine-stranded conductor
0.2 … 6?mm2?/ 24 … 10?AWG
Strip length
12 … 13?mm?/ 0.47 … 0.51?inches
Wiring direction
Side-entry wiring

Specifications may be subject to change without notice