wago 285-1167

Selling Points

  • 1High Current Capability: Handles conductors up to 350 kcmil (185mm²) for robust electrical connections.
  • 2Reliable Clamping: Features the CAGE CLAMP technology, ensuring secure and vibration-proof connections.
  • 3Marine and Railway Ready: Meets stringent requirements for marine and railway applications, ensuring durability in harsh environments.
  • 4Heat and Cold Resistance: Withstands extreme temperatures, maintaining performance under heavy loads.
  • 5Maintenance-Free Operation: Long-term consistency of electrical and mechanical properties reduces service costs and enhances equipment reliability.
Product Details
285-1167
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Clamping units
2
Total number of potentials
1
Number of levels
1
Number of jumper slots
2
Width
32?mm?/ 1.26?inches
Height from the surface
123?mm?/ 4.843?inches
Depth
170?mm?/ 6.693?inches
Mounting type
Mounting flanges
Marking level
Side marking
Note (material data)
Information on material specifications can be found here
Color
dark gray/yellow
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Fire load
5.446MJ
Weight
546.4g
Processing temperature
-35 … +85?°C
Continuous operating temperature
-60 … +105?°C
eCl@ss 10.0
27-14-11-20
eCl@ss 9.0
27-14-11-20
ETIM 9.0
EC000897
ETIM 8.0
EC000897
ECCN
NO US CLASSIFICATION
PU (SPU)
4?pcs
Packaging type
box
Country of origin
DE
GTIN
4055143424134
Customs tariff number
8536904000
RoHS Compliance Status
Compliant,No Exemption
Ratings per
IEC/EN 60947-7-1
Rated voltage (III / 3)
1000V
Rated impulse voltage (III / 3)
12kV
Rated current
353A
Legend (ratings)
(III / 3) ? Overvoltage category III / Pollution degree 3
Rated voltage (III/3) 2
1500V
Rated surge voltage (III/3) 2
12kV
Approvals per
CSA 22.2 No 158
Rated voltage UL (Use Group B)
600V
Rated current UL (Use Group B)
310A
Rated voltage UL (Use Group C)
600V
Rated current UL (Use Group C)
310A
Rated voltage CSA (Use Group B)
1000V
Rated current CSA (Use Group B)
310A
Rated voltage CSA (Use Group C)
1000V
Rated current CSA (Use Group D)
310A
Power loss, per pole (potential)
11.215W
Rated current I<sub>N</sub> for specified power loss
353A
Resistance value for specified, current-dependent power loss
Voltage type 1
AC/DC
Voltage type 2
DC
Connection technology
POWER CAGE CLAMP
Actuation type
T-wrench; 8 mm
Connectable conductor materials
Copper
Nominal cross-section
185 mm2 / 350 kcmil
Solid conductor
50 … 185?mm2?/ 1/0?AWG … 350?kcmil
Stranded conductor
50 … 185?mm2?/ 1/0?AWG … 350?kcmil
Fine-stranded conductor
50 … 185?mm2?/ 1/0?AWG … 350?kcmil
Fine-stranded conductor; with insulated ferrule
50 … 150?mm2?/ 1/0?AWG … 300?kcmil
Fine-stranded conductor; with uninsulated ferrule
50 … 185?mm2?/ 1/0?AWG … 350?kcmil
Strip length
45 … 47?mm?/ 1.77 … 1.85?inches
Wiring direction
Side-entry wiring

Specifications may be subject to change without notice