wago 285-191

Selling Points

  • 1High Current Capability: Supports up to 232A current.
  • 2Versatile Wire Size Range: Accommodates wire sizes from 25mm² to 95mm² or #4AWG to #4/0AWG.
  • 3Durable Design: Constructed with dark gray-yellow polyamide (PA66) insulation.
  • 4Easy Installation: Mounts on DIN-35 rail with dimensions of 35 x 15mm.
  • 5Reliable Connection Technology: Features POWER CAGE CLAMP screw connections for secure wire management.
Product Details
285-191
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Clamping units
2
Total number of potentials
1
Number of levels
1
Number of jumper slots
2
Width
25?mm?/ 0.984?inches
Height
107?mm?/ 4.213?inches
Depth from upper-edge of DIN-rail
101?mm?/ 3.976?inches
Mounting type
DIN-rail mounting
Mounting (note)
only suitable for DIN 35 x 15 rail
Marking level
Side marking
Note (material data)
Information on material specifications can be found here
Color
dark gray/yellow
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Fire load
0.734MJ
Weight
260.7g
Processing temperature
-35 … +85?°C
Continuous operating temperature
-60 … +105?°C
eCl@ss 10.0
27-14-11-20
eCl@ss 9.0
27-14-11-20
ETIM 9.0
EC000897
ETIM 8.0
EC000897
ECCN
NO US CLASSIFICATION
PU (SPU)
5?pcs
Packaging type
box
Country of origin
PL
GTIN
4055143500852
Customs tariff number
8536904000
RoHS Compliance Status
Compliant,No Exemption
Ratings per
IEC/EN 60947-7-1
Rated voltage (III / 3)
1000V
Rated impulse voltage (III / 3)
12kV
Rated current
232A
Legend (ratings)
(III / 3) ? Overvoltage category III / Pollution degree 3
Rated voltage (III/3) 2
1500V
Rated surge voltage (III/3) 2
12kV
Approvals per
CSA 22.2 No 158
Rated voltage UL (Use Group B)
600V
Rated current UL (Use Group B)
200A
Rated voltage UL (Use Group C)
600V
Rated current UL (Use Group C)
200A
Rated voltage CSA (Use Group B)
1000V
Rated current CSA (Use Group B)
210A
Rated voltage CSA (Use Group C)
1000V
Rated current CSA (Use Group D)
210A
Power loss, per pole (potential)
7.535W
Rated current I<sub>N</sub> for specified power loss
232A
Resistance value for specified, current-dependent power loss
Voltage type 1
AC/DC
Voltage type 2
DC
Connection technology
POWER CAGE CLAMP
Actuation type
T-wrench; 8 mm
Connectable conductor materials
Copper
Nominal cross-section
95 mm2
Solid conductor
25 … 95?mm2?/ 4 … 4/0?AWG
Stranded conductor
25 … 95?mm2?/ 4 … 4/0?AWG
Fine-stranded conductor
25 … 95?mm2?/ 4 … 4/0?AWG
Fine-stranded conductor; with insulated ferrule
25 … 95?mm2?/ 4 … 4/0?AWG
Fine-stranded conductor; with uninsulated ferrule
25 … 95?mm2?/ 4 … 4/0?AWG
Strip length
35?mm?/ 1.38?inches
Wiring direction
Side-entry wiring

Specifications may be subject to change without notice