Selling Points

  • 1100% Mismating Protection: Ensures secure connections and prevents damage.
  • 2Lead-Free Reflow Soldering: Compatible with modern PCB assembly processes.
  • 3Threaded Flange: Easy mounting and secure positioning on PCBs.
  • 4High-Voltage Rating: Rated for 80 V (III / 3) and 250 V (II / 2) with 10 A current.
  • 5Durable Construction: Made from polyphthalamide (PPA GF) insulation material for long-lasting performance.
Product Details
713-1416/107-000
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Safety information
TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated.
Variants:
Other pole numbers
Total number of potentials
32
Number of connection types
1
Number of levels
2
Pin spacing
3.5?mm?/ 0.138?inches
Width
66.1?mm?/ 2.602?inches
Height
17.3?mm?/ 0.681?inches
Height from the surface
13.5?mm?/ 0.531?inches
Depth
13.3?mm?/ 0.524?inches
Solder pin length
3.8mm
Solder pin dimensions
0.8 x 0.8?mm
Drilled hole diameter with tolerance
1.2(+0.1)mm
Variable coding
Yes
Anti-rotation protection
Yes
Contact type (pluggable connector)
Male connector/plug
Connector (connection type)
for PCB
Mismating protection
Yes
Plugging without loss of pin spacing
No
Mating direction to the PCB
90°
Locking of plug-in connection
Threaded flange
PCB contact
THT
Solder pin arrangement
over the entire male connector (in-line)
Number of solder pins per potential
1
Note (material data)
Information on material specifications can be found here
Color
black
Material group
I
Insulation material (main housing)
Polyphthalamide (PPA GF)
Flammability class per UL94
V0
Contact material
Electrolytic copper (ECu)
Contact plating
Tin
Fire load
0.173MJ
Weight
8.7g
Limit temperature range
-60 … +100?°C
Processing temperature
-35 … +60?°C
Product Group
3 (Multi Conn. System)
eCl@ss 10.0
27-44-04-02
eCl@ss 9.0
27-44-04-02
ETIM 9.0
EC002637
ETIM 8.0
EC002637
ECCN
NO US CLASSIFICATION
PU (SPU)
10?pcs
Packaging type
box
Country of origin
PL
GTIN
4045454809065
Customs tariff number
8536694040
CAS-No.
7439-92-1
REACH Candidate List Substance
Lead
RoHS Compliance Status
Compliant,With Exemption
RoHS Exemption
6(c)
SCIP notification number (Austria)
a0f15684-cea0-4e07-9925-d862b7839532
SCIP notification number (Belgium)
46ae52e6-b588-4554-b2c4-cbad074878e6
SCIP notification number (Bulgaria)
532b8c88-0d4b-4919-b7db-2778b2802ae9
SCIP notification number (Czech Republic)
146ac79f-e120-49d5-9f21-7e1d2bad4610
SCIP notification number (Denmark)
b954bbbe-5e9f-4d00-bd7f-8f92a73cb600
SCIP notification number (Finland)
f710d4a8-e5a3-4457-99c9-6c5c222aa30f
SCIP notification number (France)
1c26c1de-189e-4413-86a5-5bfbbdbd1086
SCIP notification number (Germany)
f79769fe-f7db-466d-9c75-cdab92841496
SCIP notification number (Hungary)
8ddbb2bf-f87f-4c1a-bcd3-1a77c3a4906c
SCIP notification number (Italy)
1fd6b36b-fc58-4e9b-980b-1dc0bf11af23
SCIP notification number (Netherlands)
8969c9ab-8b1d-4a7c-961f-fa8f487d6ffa
SCIP notification number (Poland)
0a1745fd-0989-44d1-82d2-67039e7748de
SCIP notification number (Romania)
051375dd-4a9b-4c9f-80df-d490c98649d3
SCIP notification number (Sweden)
355f4903-0a6a-475a-81ec-38081ee0f8b4
Ratings per
IEC/EN 60664-1
Rated voltage (III / 3)
80V
Rated impulse voltage (III / 3)
2.5kV
Rated voltage (III/2)
160V
Rated surge voltage (III/2)
2.5kV
Nominal voltage (II/2)
250V
Rated surge voltage (II/2)
2.5kV
Rated current
10A
Legend (ratings)
(III / 2) ? Overvoltage category III / Pollution degree 2
Approvals per
CSA
Rated voltage UL (Use Group B)
150V
Rated current UL (Use Group B)
10A
Rated voltage UL (Use Group C)
50V
Rated current UL (Use Group C)
10A
Rated voltage CSA (Use Group B)
150V
Rated current CSA (Use Group B)
12A
Number of poles
32

Specifications may be subject to change without notice