Selling Points

  • 1Secure and maintenance-free connections.
  • 2Compatible with DIN-35 rail/panel mounting.
  • 3Snap-in mounting feet for easy installation.
  • 4Meets high standards of performance and safety.
  • 5Versatile choice for engineers and technicians in the field.
Product Details
731-642/018-000
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Safety information
TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated.
Variants:
Other pole numbers
Clamping units
12
Total number of potentials
12
Number of connection types
1
Number of levels
1
Pin spacing
7.62?mm?/ 0.3?inches
Width
92.1?mm?/ 3.626?inches
Height
18.8?mm?/ 0.74?inches
Height from the surface
14.3?mm?/ 0.563?inches
Depth
27.5?mm?/ 1.083?inches
Drilled hole diameter for snap-in mounting foot with tolerance
3.5(+0.1)mm
Variable coding
Yes
Housing sheet thickness
0.6 … 1.2?mm?/ 0.024 … 0.047?inches
Mounting type
Panel mounting
Anti-rotation protection
Yes
Contact type (pluggable connector)
Male connector/plug
Connector (connection type)
for conductor
Mismating protection
No
Plugging without loss of pin spacing
No
Locking of plug-in connection
none
Note (material data)
Information on material specifications can be found here
Color
orange
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Clamping spring material
Chrome-nickel spring steel (CrNi)
Contact material
Electrolytic copper (ECu)
Contact plating
Tin
Fire load
0.419MJ
Weight
21.6g
Limit temperature range
-60 … +100?°C
Processing temperature
-35 … +60?°C
Product Group
3 (Multi Conn. System)
eCl@ss 10.0
27-44-03-09
eCl@ss 9.0
27-44-03-09
ETIM 9.0
EC002638
ETIM 8.0
EC002638
ECCN
NO US CLASSIFICATION
PU (SPU)
25?pcs
Packaging type
box
Country of origin
DE
GTIN
4044918268400
Customs tariff number
8536694040
RoHS Compliance Status
Compliant,No Exemption
Ratings per
IEC/EN 60664-1
Rated voltage (III / 3)
500V
Rated impulse voltage (III / 3)
6kV
Rated voltage (III/2)
630V
Rated surge voltage (III/2)
6kV
Nominal voltage (II/2)
1000V
Rated surge voltage (II/2)
6kV
Rated current
12A
Legend (ratings)
(III / 2) ? Overvoltage category III / Pollution degree 2
Approvals per
CSA
Rated voltage UL (Use Group B)
300V
Rated current UL (Use Group B)
15A
Rated voltage UL (Use Group D)
300V
Rated current UL (Use Group D)
10A
Rated voltage (UL 1977)
600V
Rated current UL 1977
15A
Rated voltage CSA (Use Group B)
300V
Rated current CSA (Use Group B)
15A
Rated voltage CSA (Use Group D)
300V
Rated current CSA (Use Group D)
10A
Connection technology
CAGE CLAMP?
Actuation type
Operating tool
Actuation direction 1
Operation parallel to conductor entry
Actuation direction 2
Operation perpendicular to conductor entry
Solid conductor
0.08 … 2.5?mm2?/ 28 … 12?AWG
Fine-stranded conductor
0.08 … 2.5?mm2?/ 28 … 12?AWG
Fine-stranded conductor; with insulated ferrule
0.25 … 1.5?mm2
Fine-stranded conductor; with uninsulated ferrule
0.25 … 2.5?mm2
Strip length
8 … 9?mm?/ 0.31 … 0.35?inches
Number of poles
12
Conductor entry direction to mating direction
Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment
DIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests
DIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation location
Service life test, Category?1, Class?A/B
Function test with noise-like vibration
Test passed according to Section 8 of the standard
Frequency
f1= 5 Hz to f2= 150 Hz
Acceleration
5g (highest test level used for all axes)
Test duration per axis
5 h
Test directions
X, Y and Z axes
Monitoring for contact faults/interruptions
Passed
Voltage drop measurement before and after each axis
Passed
Simulated service life test through increased levels of noise-like vibration
Test passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptions
Passed
Extended test scope: Voltage drop measurement before and after each axis
Passed
Shock test
Test passed according to Section 10 of the standard
Shock form
Half sine
Shock duration
30 ms
Number of shocks per axis
3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipment
Passed

Specifications may be subject to change without notice