Product Model
734-137/108-000

Selling Points
- 1100% protected against mismating for secure connections.
- 2Straight design with 1.0 x 1.0 mm solder pins for easy PCB mounting.
- 3Threaded flange for reliable locking in place.
- 43.5 mm pin spacing for precise component placement.
- 5Light gray color with 7-pole configuration for versatile use.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Safety information | TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated. | Variants: | Other pole numbers |
Total number of potentials | 7 | Number of connection types | 1 |
Number of levels | 1 | Pin spacing | 3.5?mm?/ 0.138?inches |
Width | 34?mm?/ 1.339?inches | Height | 14.8?mm?/ 0.583?inches |
Height from the surface | 10.3?mm?/ 0.406?inches | Depth | 8.5?mm?/ 0.335?inches |
Solder pin length | 4.5mm | Solder pin dimensions | 1 x 1?mm |
Drilled hole diameter with tolerance | 1.4(+0.1)mm | Variable coding | Yes |
Anti-rotation protection | Yes | Contact type (pluggable connector) | Male connector/plug |
Connector (connection type) | for PCB | Mismating protection | Yes |
Plugging without loss of pin spacing | No | Mating direction to the PCB | 90° |
Locking of plug-in connection | Threaded flange | PCB contact | THT |
Solder pin arrangement | over the entire male connector (in-line) | Number of solder pins per potential | 1 |
Note (material data) | Information on material specifications can be found here | Color | light gray |
Material group | I | Insulation material (main housing) | Polyamide (PA66) |
Flammability class per UL94 | V0 | Contact material | Electrolytic copper (ECu) |
Contact plating | Tin | Fire load | 0.037MJ |
Weight | 2.3g | Limit temperature range | -60 … +100?°C |
Processing temperature | -35 … +60?°C | Product Group | 3 (Multi Conn. System) |
eCl@ss 10.0 | 27-44-04-02 | eCl@ss 9.0 | 27-44-04-02 |
ETIM 9.0 | EC002637 | ETIM 8.0 | EC002637 |
ECCN | NO US CLASSIFICATION | PU (SPU) | 100?pcs |
Packaging type | box | Country of origin | PL |
GTIN | 4045454758738 | Customs tariff number | 8536694040 |
CAS-No. | 7439-92-1 | REACH Candidate List Substance | Lead |
RoHS Compliance Status | Compliant,With Exemption | RoHS Exemption | 6(c) |
SCIP notification number (Austria) | f80dfc1e-ce01-42dc-8bbb-e73a1ecf2dad | SCIP notification number (Belgium) | 75d96169-cf8a-4d12-90bf-cec05925aef4 |
SCIP notification number (Bulgaria) | 9525514b-4011-4445-8b5f-16df5f287ebc | SCIP notification number (Czech Republic) | 6f0d481f-a8b5-42fc-8324-252e4ec0de78 |
SCIP notification number (Denmark) | 4fd2e003-f2da-461e-a05e-68173aa67f1e | SCIP notification number (Finland) | a6a416d5-1f66-4e1e-ba04-d007c3107056 |
SCIP notification number (France) | ff9e6235-56da-45e2-a0b0-8a49496e65f6 | SCIP notification number (Germany) | 1125b006-54c5-487a-90b7-ddfacddde21e |
SCIP notification number (Hungary) | d6a1827d-5010-49a8-bfe1-a5933409c578 | SCIP notification number (Italy) | d81db001-1c65-4f0d-bdf2-243afff2f98b |
SCIP notification number (Netherlands) | a6c28a94-635b-47f7-b5f9-3ede121b2d4c | SCIP notification number (Poland) | 5e5c12f1-24db-45bf-bfb3-08212968e0fe |
SCIP notification number (Romania) | 21fb8746-3735-4b4e-9587-fb1c0b1c85ae | SCIP notification number (Sweden) | 56836a63-1649-4e07-b421-bbc6a1b0f5fa |
Ratings per | IEC/EN 60664-1 | Rated voltage (III / 3) | 160V |
Rated impulse voltage (III / 3) | 2.5kV | Rated voltage (III/2) | 160V |
Rated surge voltage (III/2) | 2.5kV | Nominal voltage (II/2) | 320V |
Rated surge voltage (II/2) | 2.5kV | Rated current | 10A |
Legend (ratings) | (III / 2) ? Overvoltage category III / Pollution degree 2 | Approvals per | CSA |
Rated voltage UL (Use Group B) | 300V | Rated current UL (Use Group B) | 10A |
Rated voltage UL (Use Group D) | 300V | Rated current UL (Use Group D) | 10A |
Rated voltage CSA (Use Group B) | 300V | Rated current CSA (Use Group B) | 10A |
Rated voltage CSA (Use Group D) | 300V | Rated current CSA (Use Group D) | 10A |
Number of poles | 7 | Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment | DIN EN 50155 (VDE 0115-200):2022-06 |
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests | DIN EN 61373 (VDE 0115-0106):2011-04 | Spectrum/Installation location | Service life test, Category?1, Class?A/B |
Function test with noise-like vibration | Test passed according to Section 8 of the standard | Frequency | f1= 5 Hz to f2= 150 Hz |
Acceleration | 5g (highest test level used for all axes) | Test duration per axis | 5 h |
Test directions | X, Y and Z axes | Monitoring for contact faults/interruptions | Passed |
Voltage drop measurement before and after each axis | Passed | Simulated service life test through increased levels of noise-like vibration | Test passed according to Section 9 of the standard |
Extended test scope: Monitoring for contact faults/interruptions | Passed | Extended test scope: Voltage drop measurement before and after each axis | Passed |
Shock test | Test passed according to Section 10 of the standard | Shock form | Half sine |
Shock duration | 30 ms | Number of shocks per axis | 3 pos. und 3 neg. |
Vibration and shock stress for rolling stock equipment | Passed |
Specifications may be subject to change without notice