Product Model
734-305/109-000

Selling Points
- 1High-performance connectors for demanding industrial applications.
- 2Robust design ensures reliable connections in harsh environments.
- 3Easy installation with snap-in terminals for quick setup.
- 4Durable construction withstands high current and voltage demands.
- 5Ideal for use in automation, control systems, and electrical distribution networks.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Safety information | TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated. | Variants: | Other pole numbers |
Clamping units | 5 | Total number of potentials | 5 |
Number of connection types | 1 | Number of levels | 1 |
Pin spacing | 3.5?mm?/ 0.138?inches | Width | 27?mm?/ 1.063?inches |
Height | 13.4?mm?/ 0.528?inches | Depth | 22.3?mm?/ 0.878?inches |
Variable coding | Yes | Anti-rotation protection | Yes |
Contact type (pluggable connector) | Male connector/plug | Connector (connection type) | for conductor |
Mismating protection | Yes | Plugging without loss of pin spacing | No |
Locking of plug-in connection | Threaded flange | Note (material data) | Information on material specifications can be found here |
Color | light gray | Material group | I |
Insulation material (main housing) | Polyamide (PA66) | Flammability class per UL94 | V0 |
Clamping spring material | Chrome-nickel spring steel (CrNi) | Contact material | Electrolytic copper (ECu) |
Contact plating | Tin | Fire load | 0.091MJ |
Weight | 5g | Limit temperature range | -60 … +100?°C |
Processing temperature | -35 … +60?°C | Product Group | 3 (Multi Conn. System) |
eCl@ss 10.0 | 27-44-03-09 | eCl@ss 9.0 | 27-44-03-09 |
ETIM 9.0 | EC002638 | ETIM 8.0 | EC002638 |
ECCN | NO US CLASSIFICATION | PU (SPU) | 50?pcs |
Packaging type | box | Country of origin | PL |
GTIN | 4055143265621 | Customs tariff number | 85366930000 |
CAS-No. | 7439-92-1 | REACH Candidate List Substance | Lead |
RoHS Compliance Status | Compliant,With Exemption | RoHS Exemption | 6(c) |
SCIP notification number (Austria) | e0a579e9-ff1a-494d-b658-006c01738a98 | SCIP notification number (Belgium) | 3e9fa1af-5ebd-4cbd-ab33-154657d3a1ac |
SCIP notification number (Bulgaria) | 3ffd6769-5bdd-429e-94f2-6f583975225a | SCIP notification number (Czech Republic) | 44645ae0-9f65-49f8-8e18-c1c321e9b9f6 |
SCIP notification number (Denmark) | d885864a-5bd9-4d24-8d39-a98c8109b816 | SCIP notification number (Finland) | d44cf335-cb91-4708-9126-f0c3510f0587 |
SCIP notification number (France) | 3b9cbeb8-1cef-43d6-970b-e1dd0049b00a | SCIP notification number (Germany) | 49d2bc36-0b8b-4277-94f6-22c2b8d99142 |
SCIP notification number (Hungary) | 0d8a18af-ce6e-44c7-b06e-4f981d6ecdaa | SCIP notification number (Italy) | 8ae530a2-0bf9-4ad9-85f4-2bb47d11fa34 |
SCIP notification number (Netherlands) | 47c5f808-8fee-48d2-b96d-ff64f3991d5b | SCIP notification number (Poland) | 6de8265f-1857-4cea-b849-e966989f56d4 |
SCIP notification number (Romania) | a0eb0312-65ca-4afe-9756-f0d6ac3a0530 | SCIP notification number (Sweden) | 3d7d266a-068f-4740-8273-2f4c148a7d6b |
Ratings per | IEC/EN 60664-1 | Rated voltage (III / 3) | 160V |
Rated impulse voltage (III / 3) | 2.5kV | Rated voltage (III/2) | 160V |
Rated surge voltage (III/2) | 2.5kV | Nominal voltage (II/2) | 320V |
Rated surge voltage (II/2) | 2.5kV | Rated current | 10A |
Legend (ratings) | (III / 2) ? Overvoltage category III / Pollution degree 2 | Approvals per | CSA |
Rated voltage UL (Use Group B) | 300V | Rated current UL (Use Group B) | 10A |
Rated voltage UL (Use Group D) | 300V | Rated current UL (Use Group D) | 10A |
Rated voltage CSA (Use Group B) | 300V | Rated current CSA (Use Group B) | 10A |
Rated voltage CSA (Use Group D) | 300V | Rated current CSA (Use Group D) | 10A |
Connection technology | CAGE CLAMP? | Actuation type | Operating tool |
Actuation direction 1 | Operation parallel to conductor entry | Actuation direction 2 | Operation perpendicular to conductor entry |
Solid conductor | 0.08 … 1.5?mm2?/ 28 … 14?AWG | Fine-stranded conductor | 0.08 … 1.5?mm2?/ 28 … 14?AWG |
Fine-stranded conductor; with insulated ferrule | 0.25 … 1.5?mm2 | Fine-stranded conductor; with uninsulated ferrule | 0.25 … 1.5?mm2 |
Note (conductor cross-section) | Terminating 1.5 mm2 conductors is possible; however insulation diameter does not allow clamping units to be terminated in a row. | Strip length | 6 … 7?mm?/ 0.24 … 0.28?inches |
Number of poles | 5 | Conductor entry direction to mating direction | 0° |
Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment | DIN EN 50155 (VDE 0115-200):2022-06 | Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests | DIN EN 61373 (VDE 0115-0106):2011-04 |
Spectrum/Installation location | Service life test, Category?1, Class?A/B | Function test with noise-like vibration | Test passed according to Section 8 of the standard |
Frequency | f1= 5 Hz to f2= 150 Hz | Acceleration | 5g (highest test level used for all axes) |
Test duration per axis | 5 h | Test directions | X, Y and Z axes |
Monitoring for contact faults/interruptions | Passed | Voltage drop measurement before and after each axis | Passed |
Simulated service life test through increased levels of noise-like vibration | Test passed according to Section 9 of the standard | Extended test scope: Monitoring for contact faults/interruptions | Passed |
Extended test scope: Voltage drop measurement before and after each axis | Passed | Shock test | Test passed according to Section 10 of the standard |
Shock form | Half sine | Shock duration | 30 ms |
Number of shocks per axis | 3 pos. und 3 neg. | Vibration and shock stress for rolling stock equipment | Passed |
Specifications may be subject to change without notice