Product Model

734-313/109-000

In Stock
Last updated: 2025/4/18
wago 734-313/109-000

Selling Points

  • 1Ensures secure connections by preventing incorrect mating.
  • 2Easy cable pre-assembly and on-unit wiring for efficient installation.
  • 3Provides multiple connection points for versatile applications.
  • 4Securely locks the connector in place, preventing accidental disconnection.
  • 5Meets international safety standards for electrical connectors.
Product Details
734-313/109-000
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Safety information
TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated.
Variants:
Other pole numbers
Clamping units
13
Total number of potentials
13
Number of connection types
1
Number of levels
1
Pin spacing
3.5?mm?/ 0.138?inches
Width
55?mm?/ 2.165?inches
Height
13.4?mm?/ 0.528?inches
Depth
22.3?mm?/ 0.878?inches
Variable coding
Yes
Anti-rotation protection
Yes
Contact type (pluggable connector)
Male connector/plug
Connector (connection type)
for conductor
Mismating protection
Yes
Plugging without loss of pin spacing
No
Locking of plug-in connection
Threaded flange
Note (material data)
Information on material specifications can be found here
Color
light gray
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Clamping spring material
Chrome-nickel spring steel (CrNi)
Contact material
Electrolytic copper (ECu)
Contact plating
Tin
Fire load
0.206MJ
Weight
11.3g
Limit temperature range
-60 … +100?°C
Processing temperature
-35 … +60?°C
Product Group
3 (Multi Conn. System)
eCl@ss 10.0
27-44-03-09
eCl@ss 9.0
27-44-03-09
ETIM 9.0
EC002638
ETIM 8.0
EC002638
ECCN
NO US CLASSIFICATION
PU (SPU)
25?pcs
Packaging type
box
Country of origin
DE
GTIN
4055143266482
Customs tariff number
8536694040
CAS-No.
7439-92-1
REACH Candidate List Substance
Lead
RoHS Compliance Status
Compliant,With Exemption
RoHS Exemption
6(c)
SCIP notification number (Austria)
7dc8984b-8cae-4ec0-8d58-1184b4e5cb5a
SCIP notification number (Belgium)
aed9af0a-f934-460e-aaba-0a8885ee80e0
SCIP notification number (Bulgaria)
d8016f83-aa7d-4892-8dc8-4ff520308edb
SCIP notification number (Czech Republic)
125ff0f3-991c-4e87-a3b4-df1969ba6066
SCIP notification number (Denmark)
4b47a836-fa98-4a5b-8843-56880fcae082
SCIP notification number (Finland)
d5dcd16c-2ce7-4f0a-8ce5-b7ab3995f58d
SCIP notification number (France)
b2dd225f-818e-4ae4-b63a-992fd53e6e99
SCIP notification number (Germany)
556d7535-702d-4475-a49d-067452691d94
SCIP notification number (Hungary)
e46d885d-7a13-4e69-b204-7b06cea28387
SCIP notification number (Italy)
1658f5e7-1f57-43ca-81d3-b197daef30a0
SCIP notification number (Netherlands)
e26d086f-f2fc-49f3-97d6-e1aaadb4036a
SCIP notification number (Poland)
cf193916-87b6-4c66-931d-3a63d5883f62
SCIP notification number (Romania)
29e0889a-ed35-48df-b893-fea10de1cbb2
SCIP notification number (Sweden)
d356dcc0-bed5-4c1e-9149-4c369030542a
Ratings per
IEC/EN 60664-1
Rated voltage (III / 3)
160V
Rated impulse voltage (III / 3)
2.5kV
Rated voltage (III/2)
160V
Rated surge voltage (III/2)
2.5kV
Nominal voltage (II/2)
320V
Rated surge voltage (II/2)
2.5kV
Rated current
10A
Legend (ratings)
(III / 2) ? Overvoltage category III / Pollution degree 2
Approvals per
CSA
Rated voltage UL (Use Group B)
300V
Rated current UL (Use Group B)
10A
Rated voltage UL (Use Group D)
300V
Rated current UL (Use Group D)
10A
Rated voltage CSA (Use Group B)
300V
Rated current CSA (Use Group B)
10A
Rated voltage CSA (Use Group D)
300V
Rated current CSA (Use Group D)
10A
Connection technology
CAGE CLAMP?
Actuation type
Operating tool
Actuation direction 1
Operation parallel to conductor entry
Actuation direction 2
Operation perpendicular to conductor entry
Solid conductor
0.08 … 1.5?mm2?/ 28 … 14?AWG
Fine-stranded conductor
0.08 … 1.5?mm2?/ 28 … 14?AWG
Fine-stranded conductor; with insulated ferrule
0.25 … 1.5?mm2
Fine-stranded conductor; with uninsulated ferrule
0.25 … 1.5?mm2
Note (conductor cross-section)
Terminating 1.5 mm2 conductors is possible; however insulation diameter does not allow clamping units to be terminated in a row.
Strip length
6 … 7?mm?/ 0.24 … 0.28?inches
Number of poles
13
Conductor entry direction to mating direction
Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment
DIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests
DIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation location
Service life test, Category?1, Class?A/B
Function test with noise-like vibration
Test passed according to Section 8 of the standard
Frequency
f1= 5 Hz to f2= 150 Hz
Acceleration
5g (highest test level used for all axes)
Test duration per axis
5 h
Test directions
X, Y and Z axes
Monitoring for contact faults/interruptions
Passed
Voltage drop measurement before and after each axis
Passed
Simulated service life test through increased levels of noise-like vibration
Test passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptions
Passed
Extended test scope: Voltage drop measurement before and after each axis
Passed
Shock test
Test passed according to Section 10 of the standard
Shock form
Half sine
Shock duration
30 ms
Number of shocks per axis
3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipment
Passed

Specifications may be subject to change without notice