Product Model
734-320/019-000

Selling Points
- 1100% Protected Against Mismating: Ensures secure and stable connections.
- 2Easy Cable Pre-Assembly: Simplifies wiring with vertical and horizontal CAGE CLAMP actuation.
- 3High-Quality Material: Durable and long-lasting for industrial applications.
- 4Universal Connection: Compatible with all conductor types for versatile use.
- 5ROHS Compliant: Meets international standards for environmental safety.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Safety information | TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated. | Variants: | Other pole numbers |
Clamping units | 20 | Total number of potentials | 20 |
Number of connection types | 1 | Number of levels | 1 |
Pin spacing | 3.5?mm?/ 0.138?inches | Width | 84.8?mm?/ 3.339?inches |
Height | 13.4?mm?/ 0.528?inches | Depth | 22.3?mm?/ 0.878?inches |
Variable coding | Yes | Mounting type | Feed-through mounting |
Anti-rotation protection | Yes | Contact type (pluggable connector) | Male connector/plug |
Connector (connection type) | for conductor | Mismating protection | Yes |
Plugging without loss of pin spacing | No | Locking of plug-in connection | none |
Note (material data) | Information on material specifications can be found here | Color | light gray |
Material group | I | Insulation material (main housing) | Polyamide (PA66) |
Flammability class per UL94 | V0 | Clamping spring material | Chrome-nickel spring steel (CrNi) |
Contact material | Electrolytic copper (ECu) | Contact plating | Tin |
Fire load | 0.322MJ | Weight | 17.1g |
Limit temperature range | -60 … +100?°C | Processing temperature | -35 … +60?°C |
Product Group | 3 (Multi Conn. System) | eCl@ss 10.0 | 27-44-03-09 |
eCl@ss 9.0 | 27-44-03-09 | ETIM 9.0 | EC002638 |
ETIM 8.0 | EC002638 | ECCN | NO US CLASSIFICATION |
PU (SPU) | 25?pcs | Packaging type | box |
Country of origin | PL | GTIN | 4055143269032 |
Customs tariff number | 8536694040 | RoHS Compliance Status | Compliant,No Exemption |
Ratings per | IEC/EN 60664-1 | Rated voltage (III / 3) | 160V |
Rated impulse voltage (III / 3) | 2.5kV | Rated voltage (III/2) | 160V |
Rated surge voltage (III/2) | 2.5kV | Nominal voltage (II/2) | 320V |
Rated surge voltage (II/2) | 2.5kV | Rated current | 10A |
Legend (ratings) | (III / 2) ? Overvoltage category III / Pollution degree 2 | Approvals per | CSA |
Rated voltage UL (Use Group B) | 300V | Rated current UL (Use Group B) | 10A |
Rated voltage UL (Use Group D) | 300V | Rated current UL (Use Group D) | 10A |
Rated voltage CSA (Use Group B) | 300V | Rated current CSA (Use Group B) | 10A |
Rated voltage CSA (Use Group D) | 300V | Rated current CSA (Use Group D) | 10A |
Connection technology | CAGE CLAMP? | Actuation type | Operating tool |
Actuation direction 1 | Operation parallel to conductor entry | Actuation direction 2 | Operation perpendicular to conductor entry |
Solid conductor | 0.08 … 1.5?mm2?/ 28 … 14?AWG | Fine-stranded conductor | 0.08 … 1.5?mm2?/ 28 … 14?AWG |
Fine-stranded conductor; with insulated ferrule | 0.25 … 1.5?mm2 | Fine-stranded conductor; with uninsulated ferrule | 0.25 … 1.5?mm2 |
Note (conductor cross-section) | Terminating 1.5 mm2 conductors is possible; however insulation diameter does not allow clamping units to be terminated in a row. | Strip length | 6 … 7?mm?/ 0.24 … 0.28?inches |
Number of poles | 20 | Conductor entry direction to mating direction | 0° |
Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment | DIN EN 50155 (VDE 0115-200):2022-06 | Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests | DIN EN 61373 (VDE 0115-0106):2011-04 |
Spectrum/Installation location | Service life test, Category?1, Class?A/B | Function test with noise-like vibration | Test passed according to Section 8 of the standard |
Frequency | f1= 5 Hz to f2= 150 Hz | Acceleration | 5g (highest test level used for all axes) |
Test duration per axis | 5 h | Test directions | X, Y and Z axes |
Monitoring for contact faults/interruptions | Passed | Voltage drop measurement before and after each axis | Passed |
Simulated service life test through increased levels of noise-like vibration | Test passed according to Section 9 of the standard | Extended test scope: Monitoring for contact faults/interruptions | Passed |
Extended test scope: Voltage drop measurement before and after each axis | Passed | Shock test | Test passed according to Section 10 of the standard |
Shock form | Half sine | Shock duration | 30 ms |
Number of shocks per axis | 3 pos. und 3 neg. | Vibration and shock stress for rolling stock equipment | Passed |
Specifications may be subject to change without notice