Product Model

738-412

In Stock
Last updated: 2025/4/18
wago 738-412

Selling Points

  • 1High-density, quadruple-deck design for space-efficient wiring.
  • 248-pole connection points with 5.08 mm pin spacing.
  • 3CAGE CLAMP technology for fast and secure conductor termination.
  • 4Supports solid and fine-stranded conductors up to 2.5 mm².
  • 5Meets IEC/EN 60664-1 standards for overvoltage protection.
Product Details
738-412
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Variants:
Other pole numbers
Clamping units
48
Total number of potentials
48
Number of connection types
1
Number of levels
4
Pin spacing
5.08?mm?/ 0.2?inches
Width
61.96?mm?/ 2.439?inches
Height
48.2?mm?/ 1.898?inches
Height from the surface
44.2?mm?/ 1.74?inches
Depth
37.5?mm?/ 1.476?inches
Solder pin length
4mm
Solder pin dimensions
0.7 x 0.7?mm
Drilled hole diameter with tolerance
1.3(+0.1)mm
PCB contact
THT
Solder pin arrangement
within the terminal block (staggered)
Number of solder pins per potential
1
Note (material data)
Information on material specifications can be found here
Color
orange
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Clamping spring material
Chrome-nickel spring steel (CrNi)
Contact material
Electrolytic copper (ECu)
Contact plating
Tin
Fire load
0.993MJ
Weight
72.7g
Limit temperature range
-60 … +105?°C
Product Group
4 (Printed Circuit Connectors)
eCl@ss 10.0
27-44-04-01
eCl@ss 9.0
27-44-04-01
ETIM 9.0
EC002643
ETIM 8.0
EC002643
ECCN
NO US CLASSIFICATION
PU (SPU)
12?pcs
Packaging type
box
Country of origin
PL
GTIN
4045454159955
Customs tariff number
8536904000
RoHS Compliance Status
Compliant,No Exemption
Ratings
between the decks
Ratings per
IEC/EN 60664-1
Rated voltage (III / 3)
250V
Rated impulse voltage (III / 3)
4kV
Rated voltage (III/2)
320V
Rated surge voltage (III/2)
4kV
Nominal voltage (II/2)
630V
Rated surge voltage (II/2)
4kV
Rated current
18A
Legend (ratings)
(III / 2) ? Overvoltage category III / Pollution degree 2
Ratings per 2
IEC/EN 60664-1
Rated voltage (III/3) 2
320V
Rated surge voltage (III/3) 2
4kV
Rated voltage (III/2) 2
320V
Rated surge voltage (III/2) 2
4kV
Rated voltage (II/2) 2
630V
Rated surge voltage (II/2) 2
4kV
Rated current 2
18A
Approvals per
CSA
Rated voltage UL (Use Group B)
300V
Rated current UL (Use Group B)
10A
Rated voltage UL (Use Group D)
300V
Rated current UL (Use Group D)
10A
Rated voltage CSA (Use Group B)
300V
Rated current CSA (Use Group B)
10A
Rated voltage CSA (Use Group D)
300V
Rated current CSA (Use Group D)
10A
Connection technology
CAGE CLAMP?
Actuation type
Operating tool
Solid conductor
0.08 … 2.5?mm2?/ 28 … 12?AWG
Fine-stranded conductor
0.08 … 2.5?mm2?/ 28 … 12?AWG
Fine-stranded conductor; with insulated ferrule
0.25 … 1.5?mm2
Fine-stranded conductor; with uninsulated ferrule
0.25 … 2.5?mm2
Note (conductor cross-section)
12 AWG: THHN, THWN
Strip length
5 … 6?mm?/ 0.2 … 0.24?inches
Conductor connection direction to PCB
45°
Number of poles
48

Specifications may be subject to change without notice