Product Model

740-109

In Stock
Last updated: 2025/4/20
wago 740-109

Selling Points

  • 1Secure and maintenance-free connections with CAGE CLAMP technology.
  • 22.5 mm² cross-section for reliable electrical performance.
  • 39-pole design for multiple connection points.
  • 45 mm pin spacing for easy PCB integration.
  • 5UL and CSA approvals for high standards of performance and safety.
Product Details
740-109
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Variants:
Other pole numbers
Clamping units
9
Total number of potentials
9
Number of connection types
1
Number of levels
1
Pin spacing
5 mm / 0.197 inches
Width
45 mm / 1.772 inches
Height
23.3 mm / 0.917 inches
Height from the surface
18.2 mm / 0.717 inches
Depth
11.1 mm / 0.437 inches
Solder pin length
5.1mm
Solder pin dimensions
0.8 x 1 mm
Drilled hole diameter with tolerance
1.3(+0.1)mm
PCB contact
THT
Solder pin arrangement
over the entire terminal strip (in-line)
Number of solder pins per potential
1
Note (material data)
Information on material specifications can be found here
Color
gray
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Clamping spring material
Chrome-nickel spring steel (CrNi)
Contact material
Electrolytic copper (ECu)
Contact plating
Tin
Fire load
0.18MJ
Weight
12.4g
Limit temperature range
-60 … +105 °C
Product Group
4 (Printed Circuit Connectors)
eCl@ss 10.0
27-44-04-01
eCl@ss 9.0
27-44-04-01
ETIM 9.0
EC002643
ETIM 8.0
EC002643
ECCN
NO US CLASSIFICATION
PU (SPU)
100 (25) pcs
Packaging type
Box
Country of origin
PL
GTIN
4055143237826
Customs tariff number
8536904000
RoHS Compliance Status
Compliant,No Exemption
Ratings per
IEC/EN 60664-1
Rated voltage (III / 3)
300V
Rated impulse voltage (III / 3)
4kV
Rated voltage (III/2)
320V
Rated surge voltage (III/2)
4kV
Nominal voltage (II/2)
630V
Rated surge voltage (II/2)
4kV
Rated current
16A
Legend (ratings)
(III / 2) ? Overvoltage category III / Pollution degree 2
Approvals per
CSA
Rated voltage UL (Use Group B)
300V
Rated current UL (Use Group B)
10A
Rated voltage UL (Use Group D)
300V
Rated current UL (Use Group D)
10A
Rated voltage CSA (Use Group B)
300V
Rated current CSA (Use Group B)
16A
Rated voltage CSA (Use Group D)
300V
Rated current CSA (Use Group D)
10A
Connection technology
CAGE CLAMP?
Actuation type
Operating tool
Solid conductor
0.08 … 2.5 mm2 / 28 … 12 AWG
Fine-stranded conductor
0.08 … 2.5 mm2 / 28 … 12 AWG
Fine-stranded conductor; with insulated ferrule
0.25 … 1.5 mm2
Fine-stranded conductor; with uninsulated ferrule
0.25 … 1.5 mm2
Note (conductor cross-section)
12 AWG: THHN, THWN
Strip length
6 … 7 mm / 0.24 … 0.28 inches
Conductor connection direction to PCB
Number of poles
9

Specifications may be subject to change without notice