Product Model

745-152

In Stock
Last updated: 2025/4/20
wago 745-152

Selling Points

  • 1Secure and stable connections with CAGE CLAMP technology.
  • 2Designed for efficient connectivity in various industrial applications.
  • 3Rated voltage up to 500 V and current up to 10 A.
  • 4Compatible with fine-stranded conductors (0.08–4 mm² / 28–12 AWG).
  • 5Meets ROHS compliance and has multiple customization options.
Product Details
745-152
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Variants:
Other pole numbers
Clamping units
2
Total number of potentials
2
Number of connection types
1
Number of levels
1
Number of jumper slots
1
Pin spacing
7.5 mm / 0.295 inches
Width
14 mm / 0.551 inches
Height
23 mm / 0.906 inches
Height from the surface
19 mm / 0.748 inches
Depth
22.9 mm / 0.902 inches
Solder pin length
4mm
Solder pin dimensions
0.8 x 1.2 mm
Drilled hole diameter with tolerance
1.5(+0.1)mm
PCB contact
THT
Solder pin arrangement
over the entire terminal strip (in-line)
Number of solder pins per potential
2
Note (material data)
Information on material specifications can be found here
Color
gray
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Clamping spring material
Chrome-nickel spring steel (CrNi)
Contact material
Electrolytic copper (ECu)
Contact plating
Tin
Fire load
0.093MJ
Weight
5g
Limit temperature range
-60 … +105 °C
Product Group
4 (Printed Circuit Connectors)
eCl@ss 10.0
27-44-04-01
eCl@ss 9.0
27-44-04-01
ETIM 9.0
EC002643
ETIM 8.0
EC002643
ECCN
NO US CLASSIFICATION
PU (SPU)
180 pcs
Packaging type
Box
Country of origin
PL
GTIN
4044918671187
Customs tariff number
8536904000
RoHS Compliance Status
Compliant,No Exemption
Ratings per
IEC/EN 60664-1
Rated voltage (III / 3)
500V
Rated impulse voltage (III / 3)
6kV
Rated voltage (III/2)
630V
Rated surge voltage (III/2)
6kV
Nominal voltage (II/2)
1000V
Rated surge voltage (II/2)
6kV
Rated current
32A
Legend (ratings)
(III / 2) ? Overvoltage category III / Pollution degree 2
Approvals per
CSA
Rated voltage UL (Use Group B)
300V
Rated current UL (Use Group B)
20A
Rated voltage UL (Use Group C)
150V
Rated current UL (Use Group C)
20A
Rated voltage UL (Use Group D)
300V
Rated current UL (Use Group D)
10A
Rated voltage CSA (Use Group B)
300V
Rated current CSA (Use Group B)
20A
Rated voltage CSA (Use Group C)
150V
Rated current CSA (Use Group C)
20A
Rated voltage CSA (Use Group D)
300V
Rated current CSA (Use Group D)
10A
Connection technology
CAGE CLAMP?
Actuation type
Operating tool
Solid conductor
0.08 … 4 mm2 / 28 … 12 AWG
Fine-stranded conductor
0.08 … 4 mm2 / 28 … 12 AWG
Fine-stranded conductor; with insulated ferrule
0.25 … 2.5 mm2
Fine-stranded conductor; with uninsulated ferrule
0.25 … 2.5 mm2
Strip length
8 … 9 mm / 0.31 … 0.35 inches
Conductor connection direction to PCB
45°
Number of poles
2

Specifications may be subject to change without notice