Product Model
750-1417/040-000

Selling Points
- 18-channel digital input: Capture and process multiple signals with precision.
- 224 VDC operation: Compatible with a wide range of industrial power supplies.
- 33 ms filter: Fast and reliable signal processing for real-time applications.
- 4Low-side switching: Efficient and safe operation in hazardous environments.
- 52-conductor connection: Simplified installation and reduced wiring complexity.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Number of digital inputs | 8 | Number of Channels | 8 |
Signal type | Digital | Signal type (voltage) | 24 VDC |
Sensor connection | 8 x (2-wire) | Input characteristic | low-side switching |
Input filter (digital) | 3ms | Input current per channel for signal (0) typ. | -2.4mA |
Voltage range for signal (0) | (UV- 5 V) … UVDC | Voltage range for signal (1) | ?3 VDC … (UV- 15 V) |
Input data width (internal) max. | 8bits | Supply voltage (system) | 5 VDC; via data contacts |
Current consumption (5 V system supply) | 12mA | Supply voltage (field) | 24 VDC (-25 … +30 %); via power jumper contacts (power supply via blade contact; transmission via spring contact); Derating must be observed! |
Dielectric strength | 510 VAC / 775 VDC; per EN 60870-2-1 | Indicators | LED (1-8) green: Status DI 1 … DI 8 |
Number of incoming power jumper contacts | 2 | Number of outgoing power jumper contacts | 2 |
Current carrying capacity (power jumper contacts) | 10A | Rated surge voltage | 1 kV |
Derating | Derating (supply voltage):Ambient temperatures under laboratory conditions: (?25 … +30°%);for ?40 … +55°°C: 24°V (?25 … +20°%);for +55 … +70°°C: 24°V (?25 … +10°%);Lower limit in all temperature ranges: ?27.5°% (including 15°% residual ripple) | Connection technology: inputs / outputs | 16 x Push-in CAGE CLAMP?(inputs) |
Connection type 1 | Input | Solid conductor | 0.25 … 1.5 mm2 / 24 … 16 AWG |
Fine-stranded conductor | 0.25 … 1.5 mm2 / 24 … 16 AWG | Strip length | 8 … 9 mm / 0.31 … 0.35 inches |
Width | 12 mm / 0.472 inches | Height | 100 mm / 3.937 inches |
Depth | 69 mm / 2.717 inches | Depth from upper-edge of DIN-rail | 61.8 mm / 2.433 inches |
Mounting type | DIN-35 rail | Color | dark gray |
Housing material | Polycarbonate; polyamide 6.6 | Fire load | 0.835MJ |
Weight | 59.8g | Conformity marking | CE |
Ambient temperature (operation) | -40 … +70 °C | Ambient temperature (storage) | -40 … +85 °C |
Protection type | IP20 | Pollution degree | 2 per IEC 61131-2 |
Operating altitude | without temperature derating: 0 … 2000 m; with temperature derating: 2000 … 5000 m (0.5 K/100 m); 5000 m (max.) | Mounting position | Horizontal left, horizontal up, vertical top and vertical bottom |
Relative humidity (without condensation) | 95% | Relative humidity (with condensation) | Short-term condensation per Class 3K7/IEC EN 60721-3-3 and E-DIN 40046-721-3 (except for wind-driven precipitation, water and ice formation) |
Vibration resistance | per IEC 60068-2-6 (acceleration: 5g), EN 60870-2-2, IEC 60721-3-1, -3, EN 50155; EN 61373 | Shock resistance | per IEC 60068-2-27 (15g/11 ms/half-sine/1,000 shocks; 25g/6 ms/1,000 shocks), EN 50155, EN 61373 |
EMC immunity to interference | per EN 61000-6-1, -2; EN 61131-2; marine applications; EN 50121-3-2; EN 50121-4, -5; EN 60255-26;EN 60870-2-1; EN 61850-3; IEC 61000-6-5; IEEE 1613; VDEW: 1994 | EMC emission of interference | per EN 61000-6-3, -4, EN 61131-2, EN 60255-26, marine applications, EN 60870-2-1, EN 61850-3, EN 50121-3-2, EN 50121-4, -5 |
Exposure to pollutants | per IEC 60068-2-42 and IEC 60068-2-43 | Permissible pollutant concentration H<sub>2</sub>S at a relative humidity < 75% | 10ppm |
Permissible pollutant concentration SO <sub> 2 </sub> at a relative humidity < 75% | 25ppm | ETIM 9.0 | EC001599 |
ETIM 8.0 | EC001599 | ECCN | NO US CLASSIFICATION |
PU (SPU) | 1 pcs | Packaging type | Box |
Country of origin | DE | Customs tariff number | 85389099990 |
CAS-No. | 1303-86-2 | REACH Candidate List Substance | Diboron trioxide |
RoHS Compliance Status | Compliant,With Exemption | RoHS Exemption | 6(c) |
SCIP notification number (Austria) | b0ae6ed0-d4b5-4e4b-8d76-3d98da63421d | SCIP notification number (Belgium) | f2a34a66-3047-4d16-a75a-4b9401713a33 |
SCIP notification number (Bulgaria) | f48e5a77-b329-4250-8c67-baf4c27dcd38 | SCIP notification number (Czech Republic) | 5525db18-b87b-491f-b379-b2de839904a6 |
SCIP notification number (Denmark) | d39501c5-40bd-4c7f-af83-b0dd509f0476 | SCIP notification number (Finland) | 7ecf4078-3270-451a-9d90-80a0f1dfb0b1 |
SCIP notification number (France) | f71a3313-d6ce-4374-9390-865f54050d58 | SCIP notification number (Germany) | 4996d038-eaeb-4c78-8ab0-8bccdcea31f6 |
SCIP notification number (Hungary) | 2ae11b20-9f20-48cd-89c1-0f97d5ed1cc4 | SCIP notification number (Italy) | 8c38cff3-7ee5-43e7-b09d-2e5ab555ac7c |
SCIP notification number (Netherlands) | becb0d63-5e44-4547-a11a-506c0780f3ad | SCIP notification number (Poland) | 380fbb3c-342b-4e26-b39f-77d4aa073563 |
SCIP notification number (Romania) | 8e2fdcec-6e04-4d1c-b684-2fd38cd41d4a | SCIP notification number (Sweden) | 04521598-e27c-4399-ac72-6808f5ac6967 |
Specifications may be subject to change without notice