Selling Points

  • 1Meets ATEX/IECEx standards for use in hazardous zones.
  • 2Directly connects to Pt and Ni resistance sensors or potentiometers.
  • 3Operates at temperatures from −40°C to 70°C and withstands vibrations up to 5g.
  • 4Resistant to electromagnetic interference and other external factors.
  • 5Suitable for integration in hazardous areas with Zone 0 sensors and actuators.
Product Details
750-481/040-000
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Note
The analog input module must only be operated via 24 VDC Ex i XTR power supply (750-606/040-000)!General information (e.g., installation regulations) on explosion protection is available in the WAGO I/O System 750 XTR manuals!
Order text
2-Channel Analog Input; RTD; Intrinsically safe
Number of analog inputs
2
Number of Channels
2
Signal type
Resistance measurement
Signal type (configurable)
Yes
Sensor connection
2 x (2-wire,?3-wire)
Sensor types
Pt100; Configurable: Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000; Resistors: 1.2 kΩ, 5 kΩ; Potentiometer setting 0 … 100 %: 1k2, 5k0
Temperature range
?200 … +850 °C (Pt), ?60 … +250 °C (Ni), ?80 … +320 °C (Ni120)
Resolution (over entire range)
0.1?°C, 0.1?Ω, 0.0049?%
Conversion time (typ. ≤)
325ms
Conversion time
150 … 500 ms (per channel)
Measurement error, reference temperature
25°C
Measurement error, deviation max (upper-range value) ≤±
0.2%
Temperature error max. (upper-range value) ≤±
0.01%/K
Measuring current (typ.)
< 0.5 mA
Intrinsically safe Ex i
Yes
Data width
2 x 16-bit data; 2 x 8-bit control/status (optional)
Supply voltage (system)
5?VDC;?via data contacts
Current consumption (5 V system supply)
25mA
Supply voltage (field)
24 VDC; (Ex i XTR power supply: Uo= max. 26.8 V); via power jumper contacts (power supply via blade contact; transmission via spring contact)
Current consumption, field supply (module with no external load)
12mA
Power consumption P<sub>max.</sub>
0.45?W
Power loss P<sub>l</sub>
0.45?W
Isolation
300?VAC system/supply
Rated surge voltage
1 kV; Rated surge voltage between intrinsically safe and non-intrinsically safe circuits: 1.5 kV (EN 60079-11)
Number of incoming power jumper contacts
2
Number of outgoing power jumper contacts
2
Current carrying capacity (power jumper contacts)
1A
Indicators
LED (A, E) green: Function AI 1, AI 2; LED (B, F) red: Error AI 1, AI 2
Identification
ATEXII 3 (1) G Ex ec [ia Ga] IIC T4 GcII (1) D [Ex ia Da] IIICI (M1) [Ex ia Ma] I
Ex standard
EN/IEC 60079-0, -7, -11
Safety-relevant data (circuit)
Uo= 7.2 V; Io= 5.8 mA; Po= 10.5 mW; linear characteristic curve
Reactances?Ex ia IIC
Lo= 100 mH; Co= 13.5 μF
Reactances Ex ia IIB
Lo= 100 mH; Co= 240 μF
Reactances Ex ia IIA
Lo= 100 mH; Co= 1000 μF
Reactances Ex ia I
Lo= 100 mH; Co= 1000 μF
Reactances (note)
Reactances without accounting for the concurrence of capacitance (Co) and inductance (Lo)
Connection technology: inputs / outputs
16 x CAGE CLAMP?
Connection type 1
Inputs/outputs
Solid conductor
0.25 … 2.5?mm2?/ 24 … 14?AWG
Fine-stranded conductor
0.25 … 2.5?mm2?/ 24 … 14?AWG
Strip length
8 … 9?mm?/ 0.31 … 0.35?inches
Width
24?mm?/ 0.945?inches
Height
100?mm?/ 3.937?inches
Depth
67.8?mm?/ 2.669?inches
Depth from upper-edge of DIN-rail
60.6?mm?/ 2.386?inches
Mounting type
DIN-35 rail
Color
blue
Housing material
Polycarbonate; polyamide 6.6
Fire load
2.031MJ
Weight
90.6g
Conformity marking
CE
Ambient temperature (operation)
-40 … +70 °C
Ambient temperature (storage)
-40 … +85 °C
Protection type
IP20
Pollution degree
2 per IEC 61131-2
Operating altitude
without temperature derating: 0 … 2000?m; with temperature derating: 2000 … 5000?m (0.5?K/100?m); 5000?m (max.)
Mounting position
Horizontal left, horizontal up, vertical top and vertical bottom
Relative humidity (without condensation)
95%
Relative humidity (with condensation)
Short-term condensation per Class 3K7/IEC EN 60721-3-3 and E-DIN 40046-721-3 (except for wind-driven precipitation, water and ice formation)
Vibration resistance
per IEC 60068-2-6 (acceleration: 5g), EN 60870-2-2, IEC 60721-3-1, -3
Shock resistance
per IEC 60068-2-27 (15g/11?ms/half-sine/1,000 shocks; 25g/6?ms/1,000 shocks), EN 61373
EMC immunity to interference
per EN 61000-6-1, -2, EN 61131-2, marine applications, EN 60255-26, EN 60870-2-1, EN 61850-3, IEC 61000-6-5, IEEE 1613, VDEW: 1994
EMC emission of interference
per EN 61000-6-3, -4, EN 61131-2, EN 60255-26, marine applications, EN 60870-2-1, EN 61850-3
Exposure to pollutants
per IEC 60068-2-42 and IEC 60068-2-43
Permissible pollutant concentration H<sub>2</sub>S at a relative humidity &#60; 75%
10ppm
Permissible pollutant concentration SO <sub> 2 </sub> at a relative humidity &#60; 75%
25ppm
eCl@ss 10.0
27-24-26-01
eCl@ss 9.0
27-24-26-01
ETIM 9.0
EC001596
ETIM 8.0
EC001596
ECCN
NO US CLASSIFICATION
PU (SPU)
1?pcs
Packaging type
Box
Country of origin
DE
Customs tariff number
8538901000
CAS-No.
1303-86-2
REACH Candidate List Substance
Diboron trioxide
RoHS Compliance Status
Compliant,With Exemption
RoHS Exemption
6(c)
SCIP notification number (Austria)
69e81412-7b1f-4ad9-bf99-324ec73f5c21
SCIP notification number (Belgium)
d1201416-d700-4aab-9998-1d986401d885
SCIP notification number (Bulgaria)
1e1c4243-a2b4-4645-ad01-d3e350520b71
SCIP notification number (Czech Republic)
c87ac4cc-246c-4236-ab0a-be343e58f7d5
SCIP notification number (Denmark)
8beb13e2-fc9b-4c82-9d05-f687a5526bf8
SCIP notification number (Finland)
915940d0-4d33-4399-9cc2-7c89de393f76
SCIP notification number (France)
43470cc2-d60a-423c-9a26-19cbd26382d1
SCIP notification number (Germany)
385f94b6-2d8e-4451-8b7e-603188ae74c2
SCIP notification number (Hungary)
863c8d28-45cf-4c07-9682-16522b95ab23
SCIP notification number (Italy)
89aec051-113c-4b78-81bf-1ca21d0323c8
SCIP notification number (Netherlands)
299766a5-9ef5-45f1-a4dd-a2da43ed7821
SCIP notification number (Poland)
a56b6acb-8420-4b79-bf8d-49d704479e66
SCIP notification number (Romania)
45c935fb-bf60-4fc8-a393-c96d76f8ee6c
SCIP notification number (Sweden)
78d77221-f829-4b50-aff8-928ccfe8ee2b

Specifications may be subject to change without notice