Product Model

750-8211/040-000

In Stock
Last updated: 2025/4/18
wago 750-8211/040-000

Selling Points

  • 1Operates from -40°C to +70°C, ensuring reliability in extreme environments.
  • 2Features 2 x RJ45 connectors, 2 x SFP ports, and support for Modbus TCP communication.
  • 3Equipped with a Cortex A8 1GHz processor and 512MB RAM + 4GB flash memory.
  • 4Constructed with polycarbonate and polyamide 6.6, offering IP20 protection and high vibration resistance.
  • 5Suitable for standard machinery control, packaging, bottling, and manufacturing systems.
Product Details
750-8211/040-000
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Communications
Modbus TCP master/slave
ETHERNET protocols
DHCP
Telecontrol protocols
IEC 60870 (additional license as slave or master)
Visualization
Web-Visu
Operating system
Real-time Linux (with PREEMPT_RT patch)
CPU
Cortex A8; 1 GHz
Programming languages per IEC 61131-3
Instruction List (IL)
Programming environment
CODESYS V3.5, Firmware Release 23 or higher
Configuration options
CODESYS V3
Transmission rate
ETHERNET: 10/100 Mbit/s; Fiber optic: 100 Mbit/s
Transmission medium (communication/fieldbus)
ETHERNET: Twisted pair S-UTP; 100 Ω; Cat. 5; 100 m maximum cable length
Main memory (RAM)
512MB
Internal memory (flash)
4096MB
Non-volatile hardware memory
128Kbytes
Program memory
CODESYS V2:?16?MB;?CODESYS V3:?32?MB
Data memory
CODESYS V2:?64?MB;?CODESYS V3:?128?MB
Non-volatile software memory
128.Kbytes
Type of memory card
SD card
Memory card slot
Push-push mechanism; Cover lid (sealable)
Number of modules per node (max.)
64
Number of modules without a bus extension (max.)
64
Input and output process image (internal) max.
1000 Words/ 1000 Words
Input and output process image (Modbus?) max.
CODESYS V2: 1000?words/1000?words; CODESYS V3: 32000?words/32000?words
Indicators
LED (SYS, RUN, I/O, U1 … U7) red/green/orange: Status of system, program, local data bus, status programmable by user (can be used via CODESYS library); LED (A, C) green: Status of system power supply, field supply
Derating
Derating (supply voltage):Ambient temperatures under laboratory conditions: (?25 … +30°%);for ?40 … +55°°C: 24°V (?25 … +20°%);for +55 … +70°°C: 24°V (?25 … +10°%);Lower limit in all temperature ranges: ?27.5°% (including 15°% residual ripple)
Supply voltage (system)
24?VDC;?via pluggable connector (CAGE CLAMP? connection); Derating must be observed!
Input current (typ.) at nominal load (24?V)
550mA
Total current (system supply)
1,700mA
Supply voltage (field)
24?VDC;?Power supply via pluggable connector (CAGE CLAMP? connection); Transmission via power jumper contacts; Derating must be observed!
Current carrying capacity (power jumper contacts)
10A
Number of outgoing power jumper contacts
2
Rated surge voltage
1?kV
Connection technology: communication/fieldbus
Modbus (TCP, UDP):?2 x RJ-45;?2 x SFP slots (e.g., with SFP module and LC fiber-optic connector)
Connection technology: system supply
2 x CAGE CLAMP?
Connection technology: field supply
4 x CAGE CLAMP?
Connection type 1
System/field supply
Solid conductor
0.25 … 2.5?mm2?/ 24 … 14?AWG
Fine-stranded conductor
0.25 … 2.5?mm2?/ 24 … 14?AWG
Strip length
8 … 9?mm?/ 0.31 … 0.35?inches
Connection technology: device configuration
1 x Male connector; 4-pole
Width
78.6?mm?/ 3.094?inches
Height
100?mm?/ 3.937?inches
Depth
71.9?mm?/ 2.831?inches
Depth from upper-edge of DIN-rail
64.7?mm?/ 2.547?inches
Weight
333.6g
Housing material
Polycarbonate; polyamide 6.6
Conformity marking
CE
Ambient temperature (operation)
-40 … +70 °C
Ambient temperature (storage)
-40 … +85 °C
Protection type
IP20
Pollution degree
2 per IEC 61131-2
Operating altitude
without temperature derating: 0 … 2000?m; with temperature derating: 2000 … 5000?m (0.5?K/100?m); 5000?m (max.)
Relative humidity (without condensation)
95%
Relative humidity (with condensation)
Short-term condensation per Class 3K7/IEC EN 60721-3-3 and E-DIN 40046-721-3 (except for wind-driven precipitation, water and ice formation)
Mounting position
Horizontal left, horizontal up, vertical top and vertical bottom
Mounting type
DIN-35 rail
Vibration resistance
per IEC 60068-2-6 (acceleration: 0.7g), EN 60870-2-2, IEC 60721-3-1, -3, EN 50155; EN 61373
Shock resistance
per IEC 60068-2-27 (15g/11?ms/half-sine/1,000 shocks; 25g/6?ms/1,000 shocks), EN 50155, EN 61373
EMC immunity to interference
per EN 61000-6-1, -2; EN 61131-2; marine applications; EN 50121-3-2; EN 50121-4, -5; EN 60255-26;EN 60870-2-1; EN 61850-3; IEC 61000-6-5; IEEE 1613; VDEW: 1994
EMC emission of interference
per EN 61000-6-3, -4, EN 61131-2, EN 60255-26, marine applications, EN 60870-2-1, EN 61850-3, EN 50121-3-2, EN 50121-4, -5
Exposure to pollutants
per IEC 60068-2-42 and IEC 60068-2-43
Fire load
2.513MJ
Permissible pollutant concentration H<sub>2</sub>S at a relative humidity &#60; 75%
10ppm
Permissible pollutant concentration SO <sub> 2 </sub> at a relative humidity &#60; 75%
25ppm
ETIM 9.0
EC000236
ETIM 8.0
EC000236
ECCN
NO US CLASSIFICATION
PU (SPU)
1?pcs
Packaging type
box
Country of origin
DE
GTIN
4066966100907
Customs tariff number
8537109160
CAS-No.
1303-86-2
REACH Candidate List Substance
2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol
RoHS Compliance Status
Compliant,With Exemption
RoHS Exemption
6(c)
SCIP notification number (Austria)
3d990742-d443-47a7-8d16-c90d457fd031
SCIP notification number (Belgium)
7a88adab-dc33-46db-9d6a-e933075a188d
SCIP notification number (Bulgaria)
c43b9fbc-b7c9-4db0-9bf2-56ac3860e1fb
SCIP notification number (Czech Republic)
64ca2167-bd3f-44d3-89eb-919a17ba9d6b
SCIP notification number (Denmark)
26dc0445-bbdf-48d7-9692-c70a6d56a12f
SCIP notification number (Finland)
58c961c1-7e45-4462-84f5-83d98b8b4cce
SCIP notification number (France)
c265a80a-6c82-4aab-8a23-d622c9843d43
SCIP notification number (Germany)
c3c72bd7-f891-4d51-b087-d045a2e61438
SCIP notification number (Hungary)
67c8cbfe-d6f4-461a-add0-d9fd7e2ebb13
SCIP notification number (Italy)
0e06a35b-9210-4887-b95b-454fa9e181b0
SCIP notification number (Netherlands)
d253d325-6590-4938-b3a4-6f0623c705aa
SCIP notification number (Poland)
2c905a7c-1701-4860-95ce-b3f3e69f70ba
SCIP notification number (Romania)
020f49b2-ef3a-446e-8d3d-b2140df75680
SCIP notification number (Sweden)
f5770968-fde4-4804-abe4-133c1b5718c5

Specifications may be subject to change without notice