Product Model

756-1203/060-200

In Stock
Last updated: 2025/4/18
wago 756-1203/060-200

Selling Points

  • 1High Durability: Built to withstand industrial environments with a bending radius of 5x cable diameter (min.) and 7.5x for multiple bends.
  • 2Reliable Connectivity: Ensures seamless integration with M12D plugs, providing a secure and efficient connection.
  • 3Halogen-Free Insulation: Uses PE insulation, ensuring safety and compliance with industrial standards.
  • 4IP67 Protection: Offers robust protection against dust and water, making it suitable for harsh environments.
  • 5Comprehensive Shielding: Equipped with overlapped aluminum-laminated foil and tinned copper braid for optimal signal integrity.
Product Details
756-1203/060-200
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
eCl@ss 10.0
27-06-18-01
eCl@ss 9.0
27-06-18-01
ETIM 9.0
EC002599
ETIM 8.0
EC002599
ECCN
NO US CLASSIFICATION
PU (SPU)
1?pcs
Packaging type
Box
Country of origin
DE
GTIN
4045454521868
Customs tariff number
8544429090
RoHS Compliance Status
Compliant,No Exemption
Operating voltage
250?V
Operating current
4A
Rated surge voltage
2?kV
Insulation resistance
≥ 5 x 108Ω/km
Contact resistance
10mΩ
Conductor resistance
< 57 Ω/km
Pollution degree
3/2 per IEC 60664-1
Protection type
IP67
Ambient (operating) temperature (static)
-40 … +70 °C
Ambient (operating) temperature (dynamic)
-40 … +70 °C
Bending diameter (min.)
200
Bending radius
Single: 5 x cable diameter (min.); Multiple: 7.5 x cable diameter (min.)
Bending cycles
3Mio.
Acceleration (min.)
4
Travel speed (max.)
4
Travel path (horizontal) max.
10
Cable length
20m
Type code
02YH(ST)C11Y 2x2x0.75/1.5-100 LI GN VZN FRNC, shielded
Overall shield
Overlapped aluminum-laminated foil and tinned copper braid, optical coverage approx. 85 %
Conductor configuration
Bare copper wire (7 x 0.25 mm)
Conductor insulation
Halogen-free PE
Sheath material
Polyurethane (PUR), halogen-free per VDE 0250 Part 818, flame resistant per IEC 60332-1-2
Connection type
M12 plug - M12 plug
Number of poles
4
Cable connection direction to mating direction
Cable connection direction to mating direction (2)
Connector interface coding (cable/adapter) 1 1
D-coded
Connector interface coding (cable/adapter) 2 1
D-coded
Housing material
TPU/TPU, black (~ RAL 9005)
Contact material
CuZn
Tightening torque
1?Nm

Specifications may be subject to change without notice