ParameterValueParameterValue
Note
Length of connection cables: 20 m
Connection technology: inputs / outputs
1 x M12-A socket; 5-pole (inputs, double assignment); 1 x M12-A plug; 4-pole (IO-Link)
Width
30 mm
Height
63 mm
Depth
24 mm
Weight
92g
Housing material
PA
Ambient temperature (operation)
-25 … +70 °C
Ambient temperature (storage)
-25 … +70 °C
Protection type
IP67
Operating altitude
0 … 4000 m
Pollution degree
2
Conformity marking
CE; UKCA
MTTF
504years
ETIM 9.0
EC001596
ETIM 8.0
EC001596
ECCN
NO US CLASSIFICATION
PU (SPU)
1 pcs
Packaging type
Box
Country of origin
DE
Customs tariff number
85176200000
RoHS Compliance Status
Compliant,No Exemption
Supply voltage
24 VDC (18 … 30 V)
Current consumption (max.)
380mA
Accuracy (+25 °C)
0.25 % of the upper-range value
Indicators
Analog input: 2 x yellow LED; Power: 1 x green LED
Number of analog inputs
2
Input signal (V)
0 … 10 V
Current carrying capacity
Total inputs (max. 200 mA)
Internal resistance
100kΩ
Signal type (voltage)
0 … 10 VDC
Communications
IO-Link Class A/B
Transmission modes
COM2 (38.4 kBaud)
IO-Link version
1.1
Process data
2 x 16-bit IN (analog)
Cycle time
4.6 ms (min.)
Parameterizable functions
Application-specific identifier, system identifier, location identifier, mean value filter