Product Model

806-205

In Stock
Last updated: 2025/4/19
wago 806-205

Selling Points

  • 1Push-in CAGE CLAMP technology ensures reliable and secure connections.
  • 2Supports solid and fine-stranded conductors from 0.2 to 1.5 mm².
  • 3Quick and easy PCB replacement without disrupting looped-through potentials.
  • 4Meets IEC/EN 60664-1 and UL 1059 standards for electrical safety.
  • 5Made from Polyamide (PA66) with a flammability class of UL94 V0 and a fire load of 0.132 MJ.
Product Details
806-205
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Variants:
Other pole numbers
Clamping units
10
Total number of potentials
5
Number of connection types
1
Number of levels
1
Pin spacing
5?mm?/ 0.197?inches
Width
26.5?mm?/ 1.043?inches
Height
23.3?mm?/ 0.917?inches
Depth
19.8?mm?/ 0.78?inches
Solder pin diameter
1mm
Contact type (pluggable connector)
Female connector/socket
Connector (connection type)
for PCB
Mating direction to the PCB
90°
Note (material data)
Information on material specifications can be found here
Color
gray
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Clamping spring material
Chrome-nickel spring steel (CrNi)
Contact material
Copper alloy
Contact plating
Tin
Fire load
0.132MJ
Weight
6.5g
Limit temperature range
-60 … +105?°C
Product Group
4 (Printed Circuit Connectors)
eCl@ss 10.0
27-44-04-01
eCl@ss 9.0
27-44-04-01
ETIM 9.0
EC002643
ETIM 8.0
EC002643
ECCN
NO US CLASSIFICATION
PU (SPU)
308?pcs
Packaging type
box
Country of origin
PL
GTIN
4045454077105
Customs tariff number
8536904000
RoHS Compliance Status
Compliant,No Exemption
Ratings per
IEC/EN 60664-1
Rated voltage (III / 3)
250V
Rated impulse voltage (III / 3)
4kV
Rated voltage (III/2)
320V
Rated surge voltage (III/2)
4kV
Nominal voltage (II/2)
630V
Rated surge voltage (II/2)
4kV
Rated current
10A
Legend (ratings)
(III / 2) ? Overvoltage category III / Pollution degree 2
Approvals per
CSA
Rated voltage UL (Use Group B)
300V
Rated current UL (Use Group B)
10A
Rated voltage UL (Use Group D)
300V
Rated current UL (Use Group D)
10A
Rated voltage CSA (Use Group B)
300V
Rated current CSA (Use Group B)
10A
Connection technology
Push-in CAGE CLAMP?
Actuation type
Operating tool
Solid conductor
0.2 … 1.5?mm2?/ 24 … 16?AWG
Fine-stranded conductor
0.2 … 1.5?mm2?/ 24 … 16?AWG
Fine-stranded conductor; with insulated ferrule
0.25 … 1?mm2
Fine-stranded conductor; with uninsulated ferrule
0.25 … 1?mm2
Strip length
9 … 10?mm?/ 0.35 … 0.39?inches
Conductor connection direction to PCB
45°
Number of poles
5

Specifications may be subject to change without notice