Product Model
831-3646

Selling Points
- 1100% protected against mismating for maximum safety.
- 2Angled solder pins for versatile mounting options.
- 3High electrical and mechanical stability with three solder pins per pole.
- 4Compatible with other WAGO products for seamless integration.
- 5Rated for 41A current and 500V nominal voltage, ensuring robust performance in various industrial settings.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Safety information | TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated. | Variants: | Other pole numbers |
Total number of potentials | 6 | Number of connection types | 1 |
Number of levels | 1 | Pin spacing | 7.62?mm?/ 0.3?inches |
Solder pin length | 4mm | Solder pin dimensions | 1 x 1.2?mm |
Drilled hole diameter with tolerance | 1.7(+0.1)mm | Variable coding | Yes |
Anti-rotation protection | Yes | Contact type (pluggable connector) | Male header |
Connector (connection type) | for PCB | Mismating protection | Yes |
Plugging without loss of pin spacing | No | Mating direction to the PCB | 180° |
Locking of plug-in connection | none | PCB contact | THT |
Solder pin arrangement | over the entire male connector (in-line) | Number of solder pins per potential | 3 |
Note (material data) | Information on material specifications can be found here | Color | light gray |
Material group | I | Insulation material (main housing) | Polyamide (PA66) |
Flammability class per UL94 | V0 | Contact material | Electrolytic copper (ECu) |
Contact plating | Tin | Fire load | 0.267MJ |
Weight | 16.8g | Limit temperature range | -60 … +105?°C |
Processing temperature | -35 … +60?°C | ETIM 9.0 | EC002637 |
ETIM 8.0 | EC002637 | ECCN | NO US CLASSIFICATION |
PU (SPU) | 24?pcs | Packaging type | Box |
Country of origin | DE | GTIN | 4066966134940 |
Customs tariff number | 85366930000 | RoHS Compliance Status | Compliant,No Exemption |
Ratings per | IEC/EN 60664-1 | Rated voltage (III / 3) | 500V |
Rated impulse voltage (III / 3) | 6kV | Rated voltage (III/2) | 630V |
Rated surge voltage (III/2) | 6kV | Nominal voltage (II/2) | 1000V |
Rated surge voltage (II/2) | 6kV | Rated current | 41A |
Legend (ratings) | (III / 2) ? Overvoltage category III / Pollution degree 2 | Approvals per | CSA |
Rated voltage UL (Use Group C) | 300V | Rated current UL (Use Group C) | 42A |
Rated voltage UL (Use Group D) | 600V | Rated current UL (Use Group D) | 5A |
Rated voltage CSA (Use Group C) | 300V | Rated current CSA (Use Group C) | 41A |
Rated voltage CSA (Use Group D) | 600V | Rated current CSA (Use Group D) | 5A |
Number of poles | 6 | Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment | DIN EN 50155 (VDE 0115-200):2022-06 |
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests | DIN EN 61373 (VDE 0115-0106):2011-04 | Spectrum/Installation location | Service life test, Category?1, Class?A/B |
Function test with noise-like vibration | Test passed according to Section 8 of the standard | Frequency | f1= 5 Hz to f2= 150 Hz |
Acceleration | 5g (highest test level used for all axes) | Test duration per axis | 5 h |
Test directions | X, Y and Z axes | Monitoring for contact faults/interruptions | Passed |
Voltage drop measurement before and after each axis | Passed | Simulated service life test through increased levels of noise-like vibration | Test passed according to Section 9 of the standard |
Extended test scope: Monitoring for contact faults/interruptions | Passed | Extended test scope: Voltage drop measurement before and after each axis | Passed |
Shock test | Test passed according to Section 10 of the standard | Shock form | Half sine |
Shock duration | 30 ms | Number of shocks per axis | 3 pos. und 3 neg. |
Vibration and shock stress for rolling stock equipment | Passed |
Specifications may be subject to change without notice