Product Model

859-355

In Stock
Last updated: 2025/4/19
wago 859-355

Selling Points

  • 1High-Performance Switching Relay: Reliable operation with 250V rated voltage and 5A continuous current.
  • 2Compact Design: 6mm width, perfect for DIN-35 rail mounting, ensuring space efficiency in control panels.
  • 3Versatile Voltage Range: Compatible with both AC and DC voltages, making it suitable for various applications.
  • 4Red Status Indicator: Easy visual confirmation of relay status with a red LED indicator.
  • 5Mechanically Durable: Designed for 5 x 10^6 switching operations, ensuring long-lasting performance.
Product Details
859-355
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Note
To protect the relay coils and contacts, inductive loads must be dampened with an effective protection circuit.
Rated voltage
300V
Rated surge voltage
4kV
Overvoltage category
III
Pollution degree
2
Dielectric strength (control/load circuit) (AC, 1?min)
4?kVrms
Dielectric strength (open contact) (AC, 1?min)
1?kVrms
Insulation type (control/load circuit)
Reinforced insulation (safe isolation)
Insulation type (adjacent devices)
Reinforced insulation (safe isolation)
Protection type
IP20; in connected state or when using 859-525 end plate
Connection technology
CAGE CLAMP?
Solid conductor
0.08 … 2.5?mm2?/ 28 … 14?AWG
Fine-stranded conductor
0.08 … 2.5?mm2?/ 28 … 14?AWG
Fine-stranded conductor; with insulated ferrule
0.08 … 1.5?mm2?/ 28 … 16?AWG
Strip length
5 … 6?mm?/ 0.2 … 0.24?inches
Width
6?mm?/ 0.236?inches
Height
91?mm?/ 3.583?inches
Depth from upper-edge of DIN-rail
56?mm?/ 2.205?inches
Mounting type
DIN-35 rail
Mounting position
Horizontal (standing/lying); vertical
Note (material data)
Information on material specifications can be found here
Color
gray
Insulation material (main housing)
Polyamide (PA66)
Material group
I
Flammability class per UL94
V0
Fire load
0.338MJ
Weight
22.3g
Ambient temperature (operation at U<sub>N</sub>)
-40 … +50 °C
Ambient temperature (storage)
-40 … +70 °C
Processing temperature
-25 … +50?°C
Temperature range of connection cable
≥ (Tambient+ 20 K)
Relative humidity
5 … 95?% (no condensation permissible)
Operating altitude (max.)
2000m
Standards/specifications
EN 61010-2-201
Product Group
6 (INTERFACE ELECTRONIC)
eCl@ss 10.0
27-37-16-01
eCl@ss 9.0
27-37-16-01
ETIM 9.0
EC001437
ETIM 8.0
EC001437
ECCN
NO US CLASSIFICATION
PU (SPU)
10?pcs
Packaging type
box
Country of origin
DE
GTIN
4055143604123
Customs tariff number
8536490050
CAS-No.
7439-92-1
REACH Candidate List Substance
2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol
RoHS Compliance Status
Compliant,With Exemption
RoHS Exemption
7(a)
SCIP notification number (Austria)
d6fb542d-16a3-4f61-8bc4-7a17871e85cf
SCIP notification number (Belgium)
6cb89b70-2e48-43d2-9b15-55f95391a5b0
SCIP notification number (Bulgaria)
9d50d9a5-1e0a-4928-b550-1f3018a185fa
SCIP notification number (Czech Republic)
eedfcfec-5f1a-413e-964a-782cf7ca2152
SCIP notification number (Denmark)
6042b07a-e4eb-42fc-8d8c-ea4aa0c38feb
SCIP notification number (Finland)
0ea200ef-b35a-46ac-b7d8-5f83c185a3ed
SCIP notification number (France)
f3af4eca-14df-4e49-b3fd-ae827ff845e6
SCIP notification number (Germany)
f6cc0992-7d53-49ab-8c3e-37941d08d141
SCIP notification number (Hungary)
92d4f6a2-3a03-4871-98e7-5d620f8becc9
SCIP notification number (Italy)
6927893b-0ac3-4da3-9a2e-3bdd8e00dc97
SCIP notification number (Netherlands)
8416b904-7bae-4e01-a93e-abba46470b47
SCIP notification number (Poland)
1e4ea1c4-dc43-4cda-9d44-4b686f049021
SCIP notification number (Romania)
6c915243-4cf5-4962-849a-2fb236f8ac42
SCIP notification number (Sweden)
072463c4-37dd-4fbd-ab59-e41fd2e5e966
Nominal input voltage U<sub>N</sub>
AC/DC?48?V
Input voltage range
-15 … +10?%
Nominal input current at U<sub>N</sub>
6?mA
Number of changeover contacts
1
Contact material (relay)
AgSnO2
Limiting continuous current
5?A
Inrush current (resistive) max.
(AC) 20?A?/ 0.02?s
Switching Voltage, Max.
AC?250?V
Switching power (resistive) max.
AC?1250?VA;?DC (see load limit curve)
Switching capacity
AC-15:?3?A?/ AC?250?V;?DC-13:?2?A?/ DC?24?V
Recommended minimum load
10?V?/ 10?mA;?24?V?/ 1?mA
Pull-in time (typ.)
15ms
Drop-out time (typ.)
25ms
Bounce time (typ.)
3.5ms
Electrical life (NO; resistive load; 23?°C)
50?x 103 switching operations
Mechanical life
5?x 10? switching operations
Switching frequency with/without load (max.)
6?min-1/ 180?min-1
Status indicator
Red LED

Specifications may be subject to change without notice